Optical fibre X-ray radiation dosimeter sensor for low dose applications

被引:0
|
作者
McCarthy, Denis [1 ]
O'Keeffe, Sinead [1 ]
Lewis, Elfed [1 ]
Sporea, Dan [2 ]
Sporea, Adelina [2 ]
Tiseanu, Ion [2 ]
机构
[1] Univ Limerick, Optic Fiber Sensors Res Ctr, Limerick, Ireland
[2] Natl Inst Laser Plasma & Radiat Phys, RO-077125 Magurele, Romania
来源
基金
欧盟第七框架计划;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An investigation into a novel extrinsic PMMA (poly methyl methacrylate) plastic optical fibre sensor to monitor low doses of ionising radiation, in real time, for radiotherapy applications is presented. The concept of the optical fibre sensor is that it measures the ionising radiation energy from a radiation source and converts that measured energy into an optical signal, which travels through the fibre optic cable to a distal fluorescent mini spectrometer, where the intensity of the peak wavelength of the fluorescent light is monitored. This newly developed sensor shows excellent response and repeatability of measurement upon excitation from a calibrated X-ray source. The work reported here is through collaboration between the University of Limerick and the National Institute for Lasers, Plasma and Radiation Physics, Magurele in Romania.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [41] RADIATION DOSE RECEIVED BY X-RAY WORKERS IN PAST
    KITABATAKE, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1965, 86 (02): : 148 - 159
  • [42] RADIATION DOSE TO STAFF IN MEDICAL X-RAY DEPARTMENTS
    ARDRAN, GM
    CROOKS, HE
    KEMP, FH
    OLIVER, R
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (359): : 600 - 601
  • [43] Radiolytic yield of ozone in air for low dose neutron and x-ray/gamma-ray radiation
    Cole, J.
    Su, S.
    Blakeley, R. E.
    Koonath, P.
    Hecht, A. A.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 95 - 98
  • [44] New X-Ray Radiation Sensor for Dosimetry Imaging
    Pace, Calogero
    Pikhay, Evgeny
    Santaniello, Anna
    Nemirovsky, Yael
    Roizin, Yakov
    APPLICATIONS IN ELECTRONICS PERVADING INDUSTRY, ENVIRONMENT AND SOCIETY, 2017, 409 : 123 - 132
  • [45] CCD image sensor degradation by X-ray radiation
    Barton, Z
    Vrba, R
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 1408 - 1410
  • [46] Low-dose X-ray fluoroscopy for image guided radiation therapy (IGRT)
    Zhang, X.
    Wang, J.
    Zhu, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S642 - S642
  • [47] Establishment of low-dose rate X-ray radiation quality and calibration of the instruments
    Li M.
    Zhao R.
    Qu B.
    Lu P.
    Song F.
    Li Y.
    Fu L.
    Wu J.
    He Jishu/Nuclear Techniques, 2022, 45 (06):
  • [48] A large core polymer optical fibre sensor for x-ray dosimetry based on luminescence occurring in the cladding
    Fitzpatrick, C
    O'Donoghue, C
    Schöbel, J
    Bastiaens, B
    van der Slot, P
    Lewis, E
    Pendrill, D
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (08) : 1586 - 1590
  • [49] Advanced low-noise X-ray readout ASIC for radiation sensor interfaces
    Noulis, Thomas
    Siskos, Stylianos
    Sarrabayrouse, Gerard
    Bary, Laurent
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2008, 55 (07) : 1854 - 1862
  • [50] Low energy X-ray dosimeter based on LYSO:Ce fluorescent powder
    Zheng, Luchuan
    Xu, Chao
    Wang, Taiqi
    Cheng, Yongkang
    Christy, Yollanda Bella
    LI, Haoyu
    Cheng, Jiayao
    Peng, Gangding
    Guo, Qiang
    APPLIED OPTICS, 2023, 62 (11) : 2734 - 2739