Optical fibre X-ray radiation dosimeter sensor for low dose applications

被引:0
|
作者
McCarthy, Denis [1 ]
O'Keeffe, Sinead [1 ]
Lewis, Elfed [1 ]
Sporea, Dan [2 ]
Sporea, Adelina [2 ]
Tiseanu, Ion [2 ]
机构
[1] Univ Limerick, Optic Fiber Sensors Res Ctr, Limerick, Ireland
[2] Natl Inst Laser Plasma & Radiat Phys, RO-077125 Magurele, Romania
来源
基金
欧盟第七框架计划;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An investigation into a novel extrinsic PMMA (poly methyl methacrylate) plastic optical fibre sensor to monitor low doses of ionising radiation, in real time, for radiotherapy applications is presented. The concept of the optical fibre sensor is that it measures the ionising radiation energy from a radiation source and converts that measured energy into an optical signal, which travels through the fibre optic cable to a distal fluorescent mini spectrometer, where the intensity of the peak wavelength of the fluorescent light is monitored. This newly developed sensor shows excellent response and repeatability of measurement upon excitation from a calibrated X-ray source. The work reported here is through collaboration between the University of Limerick and the National Institute for Lasers, Plasma and Radiation Physics, Magurele in Romania.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [31] THE GEIGER COUNTER AS AN X-RAY DOSIMETER
    FULLER, WF
    BLESS, AA
    PHYSICAL REVIEW, 1946, 69 (9-10): : 545 - 545
  • [32] A novel sensor for X-ray imaging applications
    Giakos, GC
    Shah, N
    Chowdhury, S
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (02) : 300 - 306
  • [33] X-ray radiation source for total dose radiation studies
    Bisello, D
    Candelori, A
    Kaminski, A
    Litovchenko, A
    Noah, E
    Stefanutti, L
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 713 - 715
  • [34] Evaluation of Genipin Gel Dosimeter for Depth Dose Measurement of X-Ray Beams
    Gorjiara, T.
    Hill, R.
    Kuncic, Z.
    Baldock, C.
    MEDICAL PHYSICS, 2010, 37 (06) : 3274 - +
  • [35] Investigation of isotropic radiation of low energy X-ray intra-operative radiotherapy by MAGAT gel dosimeter
    Nezhad, Zahra Alyani
    Geraily, Ghazale
    Zohari, Shahin
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [36] Low dose radiation sensor for medical therapy applications
    Anil, KG
    Vasi, J
    Lal, R
    PHYSICS OF SEMICONDUCTOR DEVICES, VOLS 1 AND 2, 1998, 3316 : 1145 - 1148
  • [37] Temporally Oversampled CMOS X-ray Photon Counting Sensor for Low Dose Fluoroscopy
    Hondongwa, Donald B.
    Fossum, Eric R.
    2017 IEEE 60TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2017, : 1101 - 1104
  • [38] The Radiation Dose Determination of the Pulsed X-ray Source
    Miloichikova, I.
    Stuchebrov, S.
    Zhaksybayeva, G.
    Wagner, A.
    20TH INTERNATIONAL CONFERENCE FOR STUDENTS AND YOUNG SCIENTISTS: MODERN TECHNIQUES AND TECHNOLOGIES (MTT'2014), 2014, 66
  • [39] NEW APPLICATIONS OF X-RAY OPTICAL TECHNIQUES
    CULHANE, JL
    CASH, W
    CATURA, RC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 251 - 264
  • [40] EFFECTIVE ULTRA LOW DOSE CT PROTOCOL WITH LOWER RADIATION DOSE THAN ABDOMINAL X-RAY
    Scotland, Kymora
    Buckley, Jean
    Nugent, James
    Nicolaou, Savvas
    Zwirewich, Charles
    McLaughlin, Patrick
    Chew, Ben
    JOURNAL OF UROLOGY, 2018, 199 (04): : E735 - E735