Optical fibre X-ray radiation dosimeter sensor for low dose applications

被引:0
|
作者
McCarthy, Denis [1 ]
O'Keeffe, Sinead [1 ]
Lewis, Elfed [1 ]
Sporea, Dan [2 ]
Sporea, Adelina [2 ]
Tiseanu, Ion [2 ]
机构
[1] Univ Limerick, Optic Fiber Sensors Res Ctr, Limerick, Ireland
[2] Natl Inst Laser Plasma & Radiat Phys, RO-077125 Magurele, Romania
来源
基金
欧盟第七框架计划;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An investigation into a novel extrinsic PMMA (poly methyl methacrylate) plastic optical fibre sensor to monitor low doses of ionising radiation, in real time, for radiotherapy applications is presented. The concept of the optical fibre sensor is that it measures the ionising radiation energy from a radiation source and converts that measured energy into an optical signal, which travels through the fibre optic cable to a distal fluorescent mini spectrometer, where the intensity of the peak wavelength of the fluorescent light is monitored. This newly developed sensor shows excellent response and repeatability of measurement upon excitation from a calibrated X-ray source. The work reported here is through collaboration between the University of Limerick and the National Institute for Lasers, Plasma and Radiation Physics, Magurele in Romania.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [21] Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging
    Arvanitis, C. D.
    Bohndiek, S. E.
    Royle, G.
    Blue, A.
    Liang, H. X.
    Clark, A.
    Prydderch, M.
    Turchetta, R.
    Speller, R.
    MEDICAL PHYSICS, 2007, 34 (12) : 4612 - 4625
  • [22] Fukushima radiation dose was equivalent to X-ray
    不详
    NEW SCIENTIST, 2017, 234 (3125) : 19 - 19
  • [23] X-ray cabinet to deliver highly characterized low-dose soft x-ray radiation to biological samples
    Sengupta, Bishwambhar
    Medlin, Donald
    Sprunk, Michael
    Napolitano, Justin
    D'Avanzo, Jaclyn
    Zheng, Xiao Ran
    Dean, Delphine
    Takacs, Endre
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (03):
  • [24] Variable Sensitivity Online Optical Fibre Radiation Dosimeter
    O'Keeffe, S.
    Lewis, E.
    Santhanam, A.
    Rolland, J. P.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 787 - +
  • [25] Effects of Magnetic Field on an Optical Fibre Radiation Dosimeter
    O'Keeffe, Sinead
    Chen, Lingxia
    Lewis, Elfed
    Grattan, Mark
    Hounsell, Alan
    Whitten, Glenn
    Schettino, Giuseppe
    2016 IEEE SENSORS, 2016,
  • [26] X-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter
    Archer, James
    Li, Enbang
    Petasecca, Marco
    Dipuglia, Andrew
    Cameron, Matthew
    Stevenson, Andrew
    Hall, Chris
    Hausermann, Daniel
    Rosenfeld, Anatoly
    Lerch, Michael
    SCIENTIFIC REPORTS, 2017, 7
  • [27] Low-dose X-ray radiation induces structural alterations in proteins
    Borshchevskiy, Valentin
    Round, Ekaterina
    Erofeev, Ivan
    Weik, Martin
    Ishchenko, Andrii
    Gushchin, Ivan
    Mishin, Alexey
    Willbold, Dieter
    Bueldt, Georg
    Gordeliy, Valentin
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2014, 70 : 2675 - 2685
  • [28] Impact of low-dose X-ray radiation on the lipidome of Chlorella vulgaris
    Casula, Mattia
    Fais, Giacomo
    Dessi, Debora
    Manis, Cristina
    Bernardini, Alessandra
    Verseux, Cyprien
    Fanti, Viviana
    Caboni, Pierluigi
    Cao, Giacomo
    Concas, Alessandro
    ALGAL RESEARCH-BIOMASS BIOFUELS AND BIOPRODUCTS, 2024, 84
  • [29] X-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter
    James Archer
    Enbang Li
    Marco Petasecca
    Andrew Dipuglia
    Matthew Cameron
    Andrew Stevenson
    Chris Hall
    Daniel Hausermann
    Anatoly Rosenfeld
    Michael Lerch
    Scientific Reports, 7
  • [30] A portable indicating x-ray dosimeter
    Krebs, RP
    Kersten, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1942, 13 (08): : 332 - 334