摘要
An investigation into a novel extrinsic PMMA (poly methyl methacrylate) plastic optical fibre sensor to monitor low doses of ionising radiation, in real time, for radiotherapy applications is presented. The concept of the optical fibre sensor is that it measures the ionising radiation energy from a radiation source and converts that measured energy into an optical signal, which travels through the fibre optic cable to a distal fluorescent mini spectrometer, where the intensity of the peak wavelength of the fluorescent light is monitored. This newly developed sensor shows excellent response and repeatability of measurement upon excitation from a calibrated X-ray source. The work reported here is through collaboration between the University of Limerick and the National Institute for Lasers, Plasma and Radiation Physics, Magurele in Romania.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [1] Low dose plastic optical fibre radiation dosimeter for clinical dosimetry applications
    O'Keeffe, S.
    Lewis, E.
    Santhanam, A.
    Winningham, A.
    Rolland, J. P.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1689 - +
  • [2] Optical fibre radiation dosimeter for radiotherapy applications
    McCarthy, D.
    O'Keeffe, S.
    Lewis, E.
    Sporea, D.
    Sporea, A.
    Tiseanu, I.
    Woulfe, P.
    Cronin, J.
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 858 - 861
  • [3] Optical Fibre Radiation Dosimetry for Low Dose Applications
    McCarthy, D.
    O'Keeffe, S.
    Leen, G.
    Lewis, E.
    2010 IEEE SENSORS, 2010, : 1663 - 1666
  • [4] Radioluminescent clad optical fibre X-ray sensor
    Fitzpatrick, C
    O'Donoghue, C
    Lewis, E
    Schöbel, J
    Bastaiens, B
    van der Slot, P
    ELECTRONICS LETTERS, 2003, 39 (22) : 1575 - 1576
  • [5] Luminescence and scintillation characteristic of LYSO:Ce dosimeter for low dose X-ray
    Zheng, Luchuan
    Xu, Chao
    Cheng, Yongkang
    Wang, Taiqi
    Yan, Yuheng
    Zhang, Changfeng
    Guo, Qiang
    Peng, Gang-ding
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS XII, 2022, 12321
  • [6] A CYTOGENETIC MODEL AS DOSIMETER FOR ABSORBED DOSE FOLLOWING X-RAY OR GAMMA-RAY RADIATION ACCIDENTS
    MINNAAR, PC
    JANSEN, S
    MEDICAL PHYSICS, 1987, 14 (04) : 712 - 712
  • [7] DIAMOND DOSIMETER FOR X-RAY AND GAMMA-RADIATION
    KOZLOV, SF
    KONOROVA, EA
    KUZNETSOV, YA
    SALIKOV, YA
    REDKO, VI
    GRINBERG, VR
    MEILMAN, ML
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 235 - 237
  • [8] The DRIM-1 medical X-ray radiation dosimeter
    Vladimirov L.V.
    Martynyuk Yu.N.
    Chikirdin E.G.
    Biomedical Engineering, 1998, 32 (3) : 177 - 179
  • [9] Investigation of External Radiation Dose Changes in Some X-ray Applications
    Coskun, A.
    Mavi, B.
    ACTA PHYSICA POLONICA A, 2015, 128 (2B) : B365 - B366
  • [10] Advanced characterization of an optical fibre sensor system based on an MPPC detector for measurement of X-ray radiation in clinical linacs
    Chen, Lingxia
    Ong, Yong Sheng
    Chen, Shuilin
    O'Keeffe, Sinead
    Gillespie, Sean
    Woulfe, Peter
    Jiang, Benxue
    Grout, Ian
    Lewis, Elfed
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 318