共 53 条
Application of carboxylic acid-functionalized of graphene oxide for electrochemical simultaneous determination of tryptophan and tyrosine in milk
被引:24
作者:
Fooladi, Ebrahim
[1
]
Razavizadeh, BiBi Marzieh
[1
]
Noori, Monireh
[1
]
Kakooei, Saeid
[2
]
机构:
[1] Res Inst Food Sci & Technol RIFST, Dept Food Safety & Qual Control, Mashhad 9185176933, Razavi Khorasan, Iran
[2] Univ Teknol Petronas, Ctr Corros Res, Mech Engn Dept, Seri Iskandar 32610, Perak Darul Rid, Malaysia
来源:
SN APPLIED SCIENCES
|
2020年
/
2卷
/
04期
基金:
美国国家科学基金会;
关键词:
Tyrosine;
Tryptophan;
Sensor;
Graphene oxide-COOH/chitosan;
Milk;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
CARBON-PASTE ELECTRODE;
AMINO-ACIDS;
SELECTIVE DETERMINATION;
NANOPARTICLES;
SENSOR;
PLATFORM;
NANOSHEETS;
D O I:
10.1007/s42452-020-2332-0
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
In this work, a new method for the simultaneous determination of tryptophan (Trp) and tyrosine (Tyr) in milk has been reported. Trp and Tyr are essential amino acids in human nutrition, but their electrochemical signal overlapped. For solve this problem, we developed modified Screen Printed Carbon Electrode (SPCE) with Graphene Oxide-COOH/Chitosan (GO-COOH/Chitosan) electro-deposition. The morphology and electrochemical performance of modified electrode were characterized by scanning electron microscopy, energy dispersive spectrometry, FT-IR, electrochemical impedance spectroscopy and cyclic voltammetry. The electrochemical simultaneous determination of Trp and Tyr has been investigated by using differential pulse voltammetry. The carboxylic acid functionalized GO modified SPCE was utilized to catalyze the oxidation of Trp and Tyr. Compared with SPCE/GO/Chitosan and SPCE/Chitosan sensor, the new sensor has enhanced sensitivity, low detection limit and high selectivity. In addition, the SPCE/GO-COOH-Chitosan sensor enhanced separation of the oxidation peak of Tyr and Trp and showed a remarkable increase in peak current for electroactive compounds, thus, it can be used for simultaneous voltammetric determination. Under the optimized experimental conditions, a linear correlation between oxidation peak current and concentration of Tyr and Trp in the ranges 0.1-60 mu M and 0.4-40 mu M with a detection limit of 0.05 mu M (S/N = 3) and 0.1 mu M (S/N = 3) were achieved, respectively. Finally, the proposed electrochemical sensor was applied for quantification of Tyr and Trp in milk samples, where standard solutions were spiked to the milk samples and recoveries were obtained. [GRAPHICS] .
引用
收藏
页数:10
相关论文