Exergy-energy-environ evaluation of combined cooling heating and power system based on a double stage compression regenerative gas turbine in large scales

被引:31
作者
Ebrahimi, Masood [1 ]
Majidi, Soran [2 ]
机构
[1] Univ Kurdistan, Sanandaj, Iran
[2] South Pars Gas Complex, Asaluyeh, Iran
关键词
CCFIP; Absorption chiller; Environmental pollution; Exergy; Gas turbine; CCHP SYSTEM; CYCLE; DESIGN; ORC; OPTIMIZATION;
D O I
10.1016/j.enconman.2017.08.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present paper a combined cooling heating and power cycle is proposed to recover exhaust and compression heat of a 35.5 MW industrial gas turbine rated in summer operation. The cogeneration cycle comprises of double stage compressor, a regenerative gas turbine, absorption chiller, pumps and heat recovery units. The thermodynamical and environmental mathematical model of the cycle is developed using the Engineering Equation Solver software. The epsilon-number of transfer unit method is used to analyze the heat recovery system. A fitness function is proposed to aggregate five thermodynamical and environmental criteria and genetic algorithm is used for optimization. The results of the gas turbine and absorption chiller models are validated with the available data in the references and good agreement is achieved. Four design parameters of combustion temperature, compression ratio, pinch point temperature difference, and evaporator temperature are used for optimization. In the optimum state, the overall energy and exergy efficiencies are about 56% and 69%. Electricity production is 42.8 MW and 6.6% and 9.4% of the fuel energy can be recovered from the compression heat and exhaust gases. This heat recovery corresponds to producing 24.5 tons/h of superheated steam at 134.8 degrees C and 167.4 kPa. The chiller produces 7.8 MW of cooling and its coefficient of performance is 0.68. The carbon monoxide, carbon dioxide and nitrogen oxides reduction are more than 87%, 17%, and 13% respectively.
引用
收藏
页码:122 / 133
页数:12
相关论文
共 29 条
[1]   Modeling of a biomass high temperature steam gasifier integrated with assisted solar energy and a micro gas turbine [J].
Campo, Pablo ;
Benitez, Teresa ;
Lee, Uisung ;
Chung, J. N. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 93 :72-83
[2]   Cycle configuration analysis and techno-economic sensitivity of biomass externally fired gas turbine with bottoming ORC [J].
Camporeale, Sergio M. ;
Pantaleo, Antonio M. ;
Ciliberti, Patrizia D. ;
Fortunato, Bernardo .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :1239-1250
[3]   Comparative analysis on off-design performance of a gas turbine and ORC combined cycle under different operation approaches [J].
Cao, Yue ;
Dai, Yiping .
ENERGY CONVERSION AND MANAGEMENT, 2017, 135 :84-100
[4]  
Cengel Y.A., 2014, Thermodynamics an Engineering Approach, V8th
[5]  
Das S, 2015, WORLD SCI NEWS, V22, P106
[6]  
Ebrahimi M., 2014, Combined Cooling, Heating and Power: Decision-Making, Design and Optimization
[7]   The environ-thermo-economical potentials of operating gas turbines in industry for combined cooling, heating, power and process (CCHPP) [J].
Ebrahimi, Masood .
JOURNAL OF CLEANER PRODUCTION, 2017, 142 :4258-4269
[8]   Integrated energy-exergy optimization of a novel micro-CCHP cycle based on MGT-ORC and steam ejector refrigerator [J].
Ebrahimi, Masood ;
Ahookhosh, Kaveh .
APPLIED THERMAL ENGINEERING, 2016, 102 :1206-1218
[9]  
EPA CHP, 2015, CAT CHP TECHN
[10]  
Hasanbeigi A., 2010, Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities