Artificial esophagus with peristaltic movement

被引:38
作者
Watanabe, M
Sekine, K
Hori, Y
Shiraishi, Y
Maeda, T
Honma, D
Miyata, G
Saijo, Y
Yambe, T
机构
[1] Tohoku Univ, Inst Dev Aging & Canc, Dept Med Engn & Cardiol, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Biomed Engn Res Org, Sendai, Miyagi 9808575, Japan
[3] Tohoku Univ, Grad Sch Med, Div Adv Surg, Sendai, Miyagi 9808575, Japan
关键词
D O I
10.1097/01.MAT.0000154644.44891.F1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we have developed an artificial esophagus simulating peristaltic movement with the use of a nickel-titanium shape memory alloy (NiTi-SMA) actuator. Serial pairs of NiTi-SMAs were placed around a Gore-Tex vascular graft in a helical position such that they obliterated the lumen of the vessel when they contracted. In an animal experiment using a goat, the cervical esophagus was resected over a length of approximately 20 cm. The artificial esophagus was anastomosed with the remaining cervical esophagus. When a direct current of 500 mA at 5 V was applied to the NiTi-SMAs, the first pair of the NiTi-SMA contracted. The following pairs of the NiTi-SMAs contracted consecutively. The entire contraction of the artificial esophagus was similar to the esophageal peristaltic movement observed by x-ray examination in humans. The results showed the possibility that the artificial esophagus could function as an artificial esophagus having peristaltic movement.
引用
收藏
页码:158 / 161
页数:4
相关论文
共 18 条
[1]   Development of an implantable artificial anal sphincter by the use of the shape memory alloy [J].
Amae, S ;
Wada, M ;
Luo, Y ;
Nakamura, H ;
Yoshida, S ;
Kamiyama, T ;
Yambe, T ;
Takagi, T ;
Nitta, S ;
Ohi, R .
ASAIO JOURNAL, 2001, 47 (04) :346-350
[2]   STRUCTURAL DETERIORATION OF PROSTHETIC ESOPHAGEAL TUBES - AN INVITRO COMPARISON OF LATEX RUBBER AND SILICONE-RUBBER TUBES [J].
BRANICKI, FJ ;
OGILVIE, AL ;
WILLIS, MR ;
ATKINSON, M .
BRITISH JOURNAL OF SURGERY, 1981, 68 (12) :861-864
[3]   LATE COMPLICATION OF ENDOSCOPIC ESOPHAGEAL TUBE INSERTION [J].
BROWN, P ;
HUGHES, RG .
BRITISH MEDICAL JOURNAL, 1979, 2 (6196) :970-971
[4]  
Davenport H.W, 1982, PHYSL DIGESTIVE TRAC
[5]   Variation in postoperative complication rates after high-risk surgery in the United States [J].
Dimick, JB ;
Pronovost, PJ ;
Cowan, JA ;
Lipsett, PA ;
Stanley, JC ;
Upchurch, GR .
SURGERY, 2003, 134 (04) :534-540
[6]  
GOLUBOVIC V, 2002, COLL ANTROPOL S, P149
[7]   Tissue-engineered esophagus: Experimental substitution by onlay patch or interposition [J].
Grikscheit, T ;
Ochoa, ER ;
Srinivasan, A ;
Gaissert, H ;
Vacanti, JP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (02) :537-544
[8]  
JAFFE BM, 1997, GASTROENTEROLOGY HEP, V5
[9]   STRUCTURAL DETERIORATION IN CELESTIN TUBES [J].
MACKENZIE, I ;
WHYTE, AS ;
TANKEL, HI .
BRITISH JOURNAL OF SURGERY, 1976, 63 (11) :851-852
[10]   HEAT DISSIPATION THROUGH THE BLOOD CONTACTING SURFACE OF A THERMALLY DRIVEN LVAS [J].
NAVARRO, RR ;
KIRALY, RJ ;
HARASAKI, H ;
NASU, M ;
NOSE, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (05) :381-386