A Systematic Review for the Design of In Vitro Flow Studies of the Carotid Artery Bifurcation

被引:15
作者
Hoving, A. M. [1 ]
de Vries, E. E. [2 ]
Mikhal, J. [1 ]
de Borst, G. J. [2 ]
Slump, C. H. [1 ]
机构
[1] Univ Twente, NL-7500 AE Enschede, Netherlands
[2] Univ Med Ctr Utrecht, NL-3584 CX Utrecht, Netherlands
关键词
Model; Design; Imaging techniques; MRI; Optical PIV; Ultrasound; WALL SHEAR-STRESS; PARTICLE IMAGE VELOCIMETRY; CARDIOVASCULAR MAGNETIC-RESONANCE; COMPUTATIONAL FLUID-DYNAMICS; BLOOD-MIMICKING FLUID; PULSATILE FLOW; EARLY ATHEROSCLEROSIS; VELOCITY-FIELDS; ULTRASOUND; MRI;
D O I
10.1007/s13239-019-00448-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose In vitro blood flow studies in carotid artery bifurcation models may contribute to understanding the influence of hemodynamics on carotid artery disease. However, the design of in vitro blood flow studies involves many steps and selection of imaging techniques, model materials, model design, and flow visualization parameters. Therefore, an overview of the possibilities and guidance for the design process is beneficial for researchers with less experience in flow studies. Methods A systematic search to in vitro flow studies in carotid artery bifurcation models aiming at quantification and detailed flow visualization of blood flow dynamics results in inclusion of 42 articles. Results Four categories of imaging techniques are distinguished: MRI, optical particle image velocimetry (PIV), ultrasound and miscellaneous techniques. Parameters for flow visualization are categorized into velocity, flow, shear-related, turbulent/disordered flow and other parameters. Model materials and design characteristics vary between study type. Conclusions A simplified three-step design process is proposed for better fitting and adequate match with the pertinent research question at hand and as guidance for less experienced flow study researchers. The three consecutive selection steps are: flow parameters, image modality, and model materials and designs. Model materials depend on the chosen imaging technique, whereas choice of flow parameters is independent from imaging technique and is therefore only determined by the goal of the study.
引用
收藏
页码:111 / 127
页数:17
相关论文
共 78 条
  • [1] Accuracy and limitations of vector flow mapping: left ventricular phantom validation using stereo particle image velocimetory
    Asami R.
    Tanaka T.
    Kawabata K.-I.
    Hashiba K.
    Okada T.
    Nishiyama T.
    [J]. Journal of Echocardiography, 2017, 15 (2) : 57 - 66
  • [2] Experimental flow studies in exact-replica phantoms of atherosclerotic carotid bifurcations under steady input conditions
    Bale-Glickman, J
    Selby, K
    Saloner, D
    Savas, Ö
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (01): : 38 - 48
  • [3] Turbulent Kinetic Energy Assessed by Multipoint 4-Dimensional Flow Magnetic Resonance Imaging Provides Additional Information Relative to Echocardiography for the Determination of Aortic Stenosis Severity
    Binter, Christian
    Gotschy, Alexander
    Suendermann, Simon H.
    Frank, Michelle
    Tanner, Felix C.
    Luescher, Thomas F.
    Manka, Robert
    Kozerke, Sebastian
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (06)
  • [4] Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements
    Botnar, R
    Rappitsch, G
    Scheidegger, MB
    Liepsch, D
    Perktold, K
    Boesiger, P
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (02) : 137 - 144
  • [5] Phase-Contrast Magnetic Resonance Imaging Measurements in Intracranial Aneurysms In Vivo of Flow Patterns, Velocity Fields, and Wall Shear Stress: Comparison with Computational Fluid Dynamics
    Boussel, Loic
    Rayz, Vitaliy
    Martin, Alastair
    Acevedo-Bolton, Gabriel
    Lawton, Michael T.
    Higashida, Randall
    Smith, Wade S.
    Young, William L.
    Saloner, David
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 409 - 417
  • [6] 3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV method
    Brunette, J.
    Mongrain, R.
    Laurier, J.
    Galaz, R.
    Tardif, J. C.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) : 1193 - 1200
  • [7] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    Buchmann, N. A.
    Atkinson, C.
    Jeremy, M. C.
    Soria, J.
    [J]. EXPERIMENTS IN FLUIDS, 2011, 50 (04) : 1131 - 1151
  • [8] Feasibility of In Vivo Measurement of Carotid Wall Shear Rate Using Spiral Fourier Velocity Encoded MRI
    Carvalho, Joao L. A.
    Nielsen, Jon-Fredrik
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1537 - 1547
  • [9] Walled Carotid Bifurcation Phantoms for Imaging Investigations of Vessel Wall Motion and Blood Flow Dynamics
    Chee, Adrian J. Y.
    Ho, Chung Kit
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (11) : 1852 - 1864
  • [10] Experimental and numerical study on the hemodynamics of stenosed carotid bifurcation
    Cheung, Sherman C. P.
    Wong, Kelvin K. L.
    Yeoh, Guan Heng
    Yang, William
    Tu, Jiyuan
    Beare, Richard
    Thanh Phan
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (04) : 319 - 328