Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT

被引:61
作者
De Zordo, Tobias [1 ]
von Lutterotti, Klemens [1 ]
Dejaco, Christian [2 ]
Soegner, Peter F. [1 ]
Frank, Renate [1 ]
Aigner, Friedrich [1 ]
Klauser, Andrea S. [1 ]
Pechlaner, Christoph [3 ]
Schoepf, U. Joseph [4 ]
Jaschke, Werner R. [1 ]
Feuchtner, Gudrun M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Graz, Dept Rheumatol, A-8036 Graz, Austria
[3] Med Univ Innsbruck, Dept Internal Med, A-6020 Innsbruck, Austria
[4] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29425 USA
关键词
Dual energy; Dual source; Computer tomography; Pulmonary embolism; Radiation; MULTIDETECTOR-ROW CT; COMPUTED-TOMOGRAPHY; LUNG PERFUSION; EMBOLISM; ANGIOGRAPHY; RECONSTRUCTION; FEASIBILITY; ARTERIES;
D O I
10.1007/s00330-011-2251-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To compare image quality and radiation dose of high-pitch dual-source computed tomography (DSCT), dual energy CT (DECT) and conventional single-source spiral CT (SCT) for pulmonary CT angiography (CTA) on a 128-slice CT system. Methods Pulmonary CTA was performed with five protocols: high-pitch DSCT (100 kV), high-pitch DSCT (120 kV), DECT (100/140 kV), SCT (100 kV), and SCT (120 kV). For each protocol, 30 sex, age, and body-mass-index (mean 25.3 kg/m(2)) matched patients were identified. Retrospectively, two observers subjectively assessed image quality, measured CT attenuation (HU +/- SD) at seven central and peripheral levels, and calculated signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR). Radiation exposure parameters (CTDIvol and DLP) were compared. Results Subjective image quality was rated good to excellent in > 92% (> 138/150) with an interobserver agreement of 91.4%. The five protocols did not significantly differ in image quality, neither by subjective, nor by objective measures (SNR, CNR). By contrast, radiation exposure differed between protocols: significant lower radiation was achieved by using high-pitch DSCT at 100 kV (p < 0.01 in all). Radiation exposure of DECT was in between SCT at 100 kV and 120 kV. Conclusions SCT, high-pitch DSCT, and DECT protocols techniques result in similar subjective and objective image quality, but radiation exposure was significantly lower with high-pitch DSCT at 100 kV. Key Points New CT protocols show promising results in pulmonary embolism assessment. High-pitch dual-source CT (DSCT) at 100 kV provides radiation dose savings for pulmonary CTA. High-pitch DSCT at 100 kV maintains diagnostic image quality for pulmonary CTA. Dual energy CT uses more radiation but also provides lung perfusion evaluation. Whether the additional perfusion data is worth the extra radiation remains undetermined.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 33 条
  • [21] Dual-Source Dual-Energy CT With Additional Tin Filtration: Dose and Image Quality Evaluation in Phantoms and In Vivo
    Primak, Andrew N.
    Giraldo, Juan Carlos Ramirez
    Eusemann, Christian D.
    Schmidt, Bernhard
    Kantor, Birgit
    Fletcher, Joel G.
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1164 - 1174
  • [22] Pulmonary embolism detection:: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients
    Qanadli, SD
    El Hajjam, M
    Mesurolle, B
    Barré, O
    Bruckert, F
    Joseph, T
    Mignon, F
    Vieillard-Baron, A
    Dubourg, O
    Lacombe, P
    [J]. RADIOLOGY, 2000, 217 (02) : 447 - 455
  • [23] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [24] Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    Remy-Jardin, Martine
    Pistolesi, Massimo
    Goodman, Lawrence R.
    Gefter, Warren B.
    Gottschalk, Alexander
    Mayo, John R.
    Sostman, H. Dirk
    [J]. RADIOLOGY, 2007, 245 (02) : 315 - 329
  • [25] Dual Energy CT of the Chest How About the Dose?
    Schenzle, Jan C.
    Sommer, Wieland H.
    Neumaier, Klement
    Michalski, Gisela
    Lechel, Ursula
    Nikolaou, Konstantin
    Becker, Christoph R.
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 347 - 353
  • [26] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Schertler, Thomas
    Scheffel, Hans
    Frauenfelder, Thomas
    Desbiolles, Lotus
    Leschka, Sebastian
    Stolzmann, Paul
    Seifert, Burkhardt
    Flohr, Thomas G.
    Marincek, Borut
    Alkadhi, Hatem
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (12) : 3179 - 3188
  • [27] MDCT angiography of the pulmonary arteries: Influence of iodine flow concentration on vessel attenuation and visualization
    Schoellnast, H
    Deutschmann, HA
    Fritz, GA
    Stessel, U
    Schaffler, GJ
    Tillich, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) : 1935 - 1939
  • [28] Spiral computed tomography for acute pulmonary embolism
    Schoepf, UJ
    Goldhaber, SZ
    Costello, P
    [J]. CIRCULATION, 2004, 109 (18) : 2160 - 2167
  • [29] Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT
    Schoepf, UJ
    Holzknecht, N
    Helmberger, TK
    Crispin, A
    Hong, C
    Becker, CR
    Reiser, MF
    [J]. RADIOLOGY, 2002, 222 (02) : 483 - 490
  • [30] Saving Dose in Triple-Rule-Out Computed Tomography Examination Using a High-Pitch Dual Spiral Technique
    Sommer, Wieland H.
    Schenzle, Jan C.
    Becker, Christoph R.
    Nikolaou, Konstantin
    Graser, Anno
    Michalski, Gisela
    Neumaier, Klement
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (02) : 64 - 71