Surface integrity and process mechanics of laser shock peening of novel biodegradable magnesium-calcium (Mg-Ca) alloy

被引:72
作者
Sealy, M. P. [1 ]
Guo, Y. B. [1 ]
机构
[1] Univ Alabama, Dept Mech Engn, Tuscaloosa, AL 35487 USA
基金
美国国家科学基金会;
关键词
Metallic biomaterial; Surface integrity; Implants; Laser shock peening; Corrosion; Finite element simulation; WAVE GENERATION; BONE-RESORPTION; SIMULATION; CORROSION; PROPERTY; PLASMA;
D O I
10.1016/j.jmbbm.2010.05.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current permanent metallic biomaterials of orthopedic implants, such as titanium, stainless steel, and cobalt-chromium alloys, have excellent corrosive properties and superior strengths. However, their strengths are often too high resulting in a stress shielding effect that is detrimental to the bone healing process. Without proper healing, costly and painful revision surgeries may be required. The close Young's modulus between magnesium-based implants and cancellous bones has the potential to minimize stress shielding while providing both biocompatibility and adequate mechanical properties. The problem with Mg implants is how to control corrosion rates so that the degradation of Mg implants matches that of bone growth. Laser shock peening (LSP) is an innovative surface treatment method to impart compressive residual stress to a novel Mg-Ca implant. The high compressive residual stress has great potential to slow corrosion rates. Therefore, LSP was initiated in this study to investigate surface topography and integrity produced by sequential peening a Mg-Ca alloy. Also, a 3D semi-infinite simulation was developed to predict the topography and residual stress fields produced by sequential peening. The dynamic mechanical behavior of the biomaterial was modeled using a user material subroutine from the internal state variable plasticity model. The temporal and spatial peening pressure was modeled using a user load subroutine. The simulated dent agrees with the measured dent topography in terms of profile and depth. Sequential peening was found to increase the tensile pile up region which is critical to orthopedic applications. The predicted residual stress profiles are also presented. (c) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 39 条
[1]   Corrosion behaviour of laser-melted magnesium alloys [J].
Abbas, G ;
Liu, Z ;
Skeldon, P .
APPLIED SURFACE SCIENCE, 2005, 247 (1-4) :347-353
[2]   Bioceramic dip-coating on Ti-6Al-4V and 316L SS implant materials [J].
Aksakal, Bunyamin ;
Hanyaloglu, C. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (05) :2097-2104
[3]   Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements [J].
Au, Anthony G. ;
Raso, V. James ;
Liggins, A. B. ;
Amirfazli, A. .
JOURNAL OF BIOMECHANICS, 2007, 40 (06) :1410-1416
[4]  
Bammann DJ, 1997, THEORETICAL AND APPLIED MECHANICS 1996, P359
[5]   Evaluation of bone plate with low-stiffness material in terms of stress distribution [J].
Benli, Semih ;
Aksoy, Sami ;
Havitcioglu, Hasan ;
Kucuk, Mumin .
JOURNAL OF BIOMECHANICS, 2008, 41 (15) :3229-3235
[6]   Wavelength dependent of laser shock-wave generation in the water-confinement regime [J].
Berthe, L ;
Fabbro, R ;
Peyre, P ;
Bartnicki, E .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (11) :7552-7555
[7]   Shock waves from a water-confined laser-generated plasma [J].
Berthe, L ;
Fabbro, R ;
Peyre, P ;
Tollier, L ;
Bartnicki, E .
JOURNAL OF APPLIED PHYSICS, 1997, 82 (06) :2826-2832
[8]   Finite element simulation of laser shock peening [J].
Braisted, W ;
Brockman, R .
INTERNATIONAL JOURNAL OF FATIGUE, 1999, 21 (07) :719-724
[9]  
CASLARU R, 2006, T NAMRI SME, V37, P159
[10]  
Clauer AH, 1996, SURFACE PERFORMANCE OF TITANIUM, P217