New demodulation method for efficient phase-rotation-based beamforming

被引:15
作者
Agarwal, Anup [1 ]
Yoo, Yang Mo
Schneider, Fabio Kurt
Gao, Changqing
Koh, Liang Mong
Kim, Yongmin
机构
[1] Univ Washington, Dept Elect Engn, Image Comp Syst Lab, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[4] Univ Tecnol Fed Parana, Acad Dept Elect, Parana, Brazil
关键词
D O I
10.1109/TUFFC.2007.437
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, we present a new demodulation method to reduce hardware complexity in phase-rotation-based beamforming. Due to its low sensitivity to phase delay errors, quadrature demodulation, which consists of mixing and lowpass filtering, is commonly used in ultrasound machines. However, because it requires two lowpass filters for each channel to remove harmonics after mixing, the direct use of quadrature demodulation is computationally expensive. To alleviate the high computational requirement in quadrature demodulation, we have developed a two-stage demodulation technique in which dynamic receive focusing is performed on the mixed signal instead of the complex baseband signal. Harmonics then are suppressed by using only two lowpass filters. When the number of channels is 32, the proposed two-stage demodulation reduces the necessary number of multiplications and additions for phase-rotation beamforming by 82.7% and 88.2%, respectively, compared to using quadrature demodulation. We have found from simulation and phantom studies that the proposed method does not incur any significant degradation in image quality in terms of axial and lateral resolution. These preliminary results indicate that the proposed two-stage demodulation method could contribute to significantly reducing the hardware complexity in phase-rotation-based beamforming while providing comparable image quality.
引用
收藏
页码:1656 / 1668
页数:13
相关论文
共 24 条
[1]   Should compression of coded waveforms be done before or after focusing? [J].
Bjerngaard, R ;
Jensen, JA .
MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 :47-58
[2]   PHASE-ERROR-FREE QUADRATURE SAMPLING TECHNIQUE IN THE ULTRASONIC B-SCAN IMAGING-SYSTEM AND ITS APPLICATION TO THE SYNTHETIC FOCUSING SYSTEM [J].
CHANG, SH ;
PARK, SB ;
CHO, GH .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (03) :216-223
[3]  
CHANG SH, 1993, P IEEE S ULTR, P1163
[4]   3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[5]   Delta-sigma oversampled ultrasound beamformer with dynamic delays [J].
Freeman, SR ;
Quick, MK ;
Morin, MA ;
Anderson, RC ;
Desilets, CS ;
Linnenbrink, TE ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :320-332
[6]   Multielement synthetic transmit aperture imaging using temporal encoding [J].
Gammelmark, KL ;
Jensen, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (04) :552-563
[7]   TRUE TIME-DELAY BANDPASS BEAMFORMING [J].
HORVAT, DCM ;
BIRD, JS ;
GOULDING, MM .
IEEE JOURNAL OF OCEANIC ENGINEERING, 1992, 17 (02) :185-192
[8]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[9]   Emergency bedside echocardiography as a tool for early detection and clinical decision making in cases of suspected pulmonary embolism - A case report [J].
Karavidas, A ;
Matsakas, E ;
Lazaros, G ;
Panou, F ;
Foukarakis, M ;
Zacharoulis, A .
ANGIOLOGY, 2000, 51 (12) :1021-1025
[10]  
Kellett John, 2004, Eur J Intern Med, V15, P335, DOI 10.1016/j.ejim.2004.06.008