Microwave-immobilized polybutadiene stationary phase for reversed-phase high-performance liquid chromatography

被引:12
作者
Lopes, NP [1 ]
Collins, KE [1 ]
Jardim, ICSF [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, LABCROM, Lab Pesquisas & Cromatol Liquida, BR-13084971 Campinas, SP, Brazil
关键词
stationary phases; LC; polybutadiene-silica stationary phases; microwave-assisted immobilization;
D O I
10.1016/j.chroma.2003.09.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polybutadiene (PBD) has been immobilized on high-performance liquid chromatography (HPLC) silica by microwave radiation at various power levels (52-663 W) and actuation times (3-60 min). Columns prepared from these reversed-phase HPLC materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (%C) and infrared spectroscopy. A microwave irradiation of 20 min at 663 W gives a layer of immobilized PBD that presented good performance. Longer irradiation times give thicker immobilized layers having less favorable chromatographic properties. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 43 条
[1]   Characterization and high performance liquid chromatographic evaluation of a new amide-functionalized reversed phase column [J].
Ascah, TL ;
Kallury, KMR ;
Szafranski, CA ;
Corman, SD ;
Liu, F .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (17-18) :3049-3073
[2]   Chromatographic evaluation of self-immobilized stationary phases for reversed-phase liquid chromatography [J].
Bottoli, CBG ;
Collins, KE ;
Collins, CH .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :87-92
[3]   Poly(alkylmethylsiloxanes) thermally immobilized on silica as stationary phases for high-performance liquid chromatography [J].
Bottoli, CBG ;
Chaudhry, ZF ;
Fonseca, DA ;
Collins, KE ;
Collins, CH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :121-128
[4]  
CHENG Y, 2000, LG GC, V18, P1163
[5]  
Collins KE, 2000, LC GC N AM, V18, P106
[6]   Thermal immobilization of poly(methyloctyl-siloxane) in the pores of chromatographic silica [J].
Collins, KE ;
Sá, ALA ;
Bottoli, CBG ;
Collins, CH .
CHROMATOGRAPHIA, 2001, 53 (11-12) :661-664
[7]   Comparison of the chromatography of octadecyl silane bonded silica and polybutadiene-coated zirconia phases based on a diverse set of cationic drugs [J].
Dai, J ;
Yang, XQ ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :63-82
[8]   THE CHEMICAL EFFECTS OF PHOTOOXIDATION ON BUTADIENE RUBBER [J].
DEPAOLI, MA .
EUROPEAN POLYMER JOURNAL, 1983, 19 (09) :761-768
[9]   Use of principal component analysis for studying the separation of pesticides on polyethylene-coated silica columns [J].
Forgács, E ;
Cserháti, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :33-39
[10]   POLYMER-COATED ALUMINA PARTICLES - CORRELATION OF STRUCTURE AND CHROMATOGRAPHIC PERFORMANCE [J].
GARBOW, JR ;
ASRAR, J ;
HARDIMAN, CJ .
CHEMISTRY OF MATERIALS, 1993, 5 (06) :869-875