Effects of Horizontal Misfit and Bar Framework Material on the Stress Distribution of an Overdenture-Retaining Bar System: A 3D Finite Element Analysis

被引:30
作者
Spazzin, Alosio O. [1 ,2 ]
Fernandes dos Santos, Mateus Bertolini [2 ]
Sobrinho, Lourenco Correr [3 ]
Consani, Rafael Leonardo X. [2 ]
Mesquita, Marcelo F. [2 ]
机构
[1] Merid Fac IMED, Sch Dent, Dept Prosthodont, Passo Fundo, RS, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodont, Piracicaba, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dent Mat Div, Dept Restorat Dent, Piracicaba, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2011年 / 20卷 / 07期
关键词
Implant prosthesis; bar material; fit; stress; finite element analysis; IMPLANT-BONE INTERFACE; DENTAL IMPLANTS; ACCURACY; BIOMECHANICS; FABRICATION; PROSTHESES; FIT;
D O I
10.1111/j.1532-849X.2011.00759.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the influence of horizontal misfit change and bar framework material on the distribution of static stresses in an overdenture-retaining bar system using finite element (FE) analysis. Materials and Methods: A 3D FE model was created including two titanium implants and a bar framework placed in the anterior part of a severely resorbed jaw. The model set was exported to mechanical simulation software, where horizontal displacement (10, 50, 100, and 200 mu m) was applied simulating the settling of the framework, which suffered shrinkage during laboratory procedures. Four barmaterials (gold alloy, silver-palladium alloy, commercially pure titanium, and cobalt-chromium alloy) were also simulated in the analysis using 50 mu m as the horizontal misfit. Data were qualitatively evaluated using von Mises stress, given by the software. Results: The misfit amplification presented a great increase in the stress levels in the inferior region of the bar, screw-retaining neck, cervical and medium third of the implant, and cortical bone tissue surrounding the implant. The higher stiffness of the bar presented a considerable increase in the stress levels in the bar framework only. Conclusion: The levels of static stresses seem to be closely linked with horizontal misfit, such that its amplification caused increased levels of stress in the structures of the overdenture-retaining bar system. On the other hand, the stiffness of the bar framework presented a lower effect on the static stress levels.
引用
收藏
页码:517 / 522
页数:6
相关论文
共 29 条
  • [1] Influence of Material of Overdenture-Retaining Bar with Vertical Misfit on Three-Dimensional Stress Distribution
    Abreu, Ricardo T.
    Spazzin, Aloisio O.
    Noritomi, Pedro Y.
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo F.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (06): : 425 - 431
  • [2] Abu-Hammad OA, 2000, INT J ORAL MAX IMPL, V15, P559
  • [3] Al-Fadda SA, 2007, INT J PROSTHODONT, V20, P125
  • [4] Al-Turki LEE, 2002, INT J PROSTHODONT, V15, P38
  • [5] Assif D, 1996, Int J Oral Maxillofac Implants, V11, P216
  • [6] Bergendal B, 1995, Int J Oral Maxillofac Implants, V10, P199
  • [7] Carr A B, 1993, J Prosthodont, V2, P2, DOI 10.1111/j.1532-849X.1993.tb00373.x
  • [8] The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    Carr, AB
    Gerard, DA
    Larsen, PE
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (05) : 500 - 509
  • [9] Craig RG., 1989, RESTORATIVE DENT MAT, V2nd
  • [10] Implant-Bone Interface Stress Distribution in Immediately Loaded Implants of Different Diameters: A Three-Dimensional Finite Element Analysis
    Ding, Xi
    Zhu, Xing-Hao
    Liao, Sheng-Hui
    Zhang, Xiu-Hua
    Chen, Hong
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05): : 393 - 402