EFFECT OF CERVICAL SYMPATHETIC BLOCK ON OPTIC NERVE SHEATH DIAMETER MEASURED BY ULTRASONOGRAPHY

被引:4
作者
Kim, Min-Soo [1 ]
Yoon, Kyung Bong [1 ]
Yoon, Duck Mi [1 ]
Kim, Do-Hyeong [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Anesthesiol & Pain Med, Anesthesia & Pain Res Inst, Seoul 120752, South Korea
关键词
Intracranial pressure; Nerve block; Optic nerve sheath diameter; Sympathetic ganglia; STELLATE GANGLION BLOCK; CEREBRAL-BLOOD-FLOW; RAISED INTRACRANIAL-PRESSURE; BRAIN-INJURY; SUBARACHNOID HEMORRHAGE; ULTRASOUND; STIMULATION; VALIDATION; SONOGRAPHY; MICE;
D O I
10.1016/j.ultrasmedbio.2015.01.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Optic nerve sheath diameter (ONSD) measurement using ocular ultrasonography was introduced as a non-invasive technique to assess intracranial pressure. We investigated changes in ONSD after cervical sympathetic block (CSB). Ultrasound-guided CSB was performed with a lateral approach at the C6 level in 35 patients. ONSD was measured before CSB and after checking for Horner's syndrome 15 minutes after CSB. The mean ONSD was significantly higher after CSB than before (5.15 +/- 0.38 mm vs. 4.75 +/- 0.32 mm, p < 0.001). A comparison of ONSDs between the blocked and non-blocked sides revealed that these values did not differ significantly between sides at baseline and after CSB. On the basis of these preliminary data, CSB caused an increase in ONSD in patients without intracranial pathology or neurologic disorders. Further larger and controlled studies of the effect of CSB on intracranial pressure in humans are needed to confirm our findings. (E-mail: breadfans@yuhs.ac) (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1599 / 1604
页数:6
相关论文
共 31 条
  • [1] CERVICAL SYMPATHETIC-NERVE STIMULATION DECREASES INTRA-CRANICAL PRESSURE IN THE CAT
    AUER, LM
    JOHANSSON, BB
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1981, 113 (04): : 565 - 566
  • [2] Ballantyne S A, 2002, Eur J Ultrasound, V15, P145, DOI 10.1016/S0929-8266(02)00036-8
  • [3] Bhatia A, 2012, CAN J ANESTH, V59, P1040, DOI 10.1007/s12630-012-9779-4
  • [4] Stellate Ganglion Block for Relieving Vasospasms After Coil Embolization of Basilar Tip Aneurysms
    Bindra, Ashish
    Prabhakar, Hemanshu
    Singh, Gyaninder Pal
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2011, 23 (04) : 379 - 379
  • [5] Blaivas M, 2003, ACAD EMERG MED, V10, P376, DOI 10.1197/aemj.10.4.376
  • [6] Increase in optic nerve sheath diameter induced by epidural blood patch: a preliminary report
    Dubost, C.
    Le Gouez, A.
    Zetlaoui, P. J.
    Benhamou, D.
    Mercier, F. J.
    Geeraerts, T.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (04) : 627 - 630
  • [7] Optic Nerve Sheath Diameter Used as Ultrasonographic Assessment of the Incidence of Raised Intracranial Pressure in Preeclampsia A Pilot Study
    Dubost, Clement
    Le Gouez, Agnes
    Jouffroy, Viridiana
    Roger-Christoph, Sandrine
    Benhamou, Dan
    Mercier, Frederic J.
    Geeraerts, Thomas
    [J]. ANESTHESIOLOGY, 2012, 116 (05) : 1066 - 1071
  • [8] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Dubourg, Julie
    Javouhey, Etienne
    Geeraerts, Thomas
    Messerer, Mahmoud
    Kassai, Behrouz
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (07) : 1059 - 1068
  • [9] EVIDENCE OF VASOCONSTRICTOR SYMPATHETIC-NERVES IN BRAIN VESSELS OF MICE
    EDVINSSON, L
    NIELSEN, KC
    OWMAN, C
    WEST, KA
    [J]. NEUROLOGY, 1973, 23 (01) : 73 - 77
  • [10] CHANGES IN CEREBRAL BLOOD VOLUME OF MICE AT VARIOUS TIME-PERIODS AFTER SUPERIOR CERVICAL SYMPATHECTOMY
    EDVINSSON, L
    OWMAN, C
    WEST, KA
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1971, 82 (04): : 521 - +