Outcomes of cataract operations in extreme high axial myopia

被引:29
作者
Lam, Jasmine K. M. [1 ,2 ]
Chan, Tommy C. Y. [1 ,2 ,3 ]
Ng, Alex L. K. [3 ]
Chow, Vanissa W. S. [1 ,2 ]
Wong, Victoria W. Y. [1 ,2 ]
Jhanji, Vishal [1 ,2 ]
机构
[1] Hong Kong Eye Hosp, 147K Argyle St, Kowloon, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
关键词
High myopia; Cataract surgery; Biometry; Retinal detachment; Complications; INTRAOCULAR-LENS POWER; ELECTRONIC MULTICENTER AUDIT; RETINAL-DETACHMENT; RISK-FACTORS; PATHOLOGICAL MYOPIA; SURGERY; EYES; PHACOEMULSIFICATION; LENGTH; COMPLICATIONS;
D O I
10.1007/s00417-016-3414-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To analyse the outcomes of phacoemulsification in extreme axial myopia Consecutive cases of phacoemulsification in eyes with axial length aeyen 30.0 mm from January 1, 2010 to Dec 31, 2013 in a tertiary referral eye hospital were retrospectively reviewed. A single intraocular lens (IOL) type was used for all cases. Main outcome measures included perioperative complications and refractive outcome. Two hundred and twenty-one eyes were identified. Intraoperatively, two eyes (0.9 %) had unstable capsular bag and three (1.4 %) had posterior capsular rupture. At a mean follow-up duration was 27.4 +/- 14.6 months, three eyes (1.5 % of 198 eyes with no history of retinal detachment or macular hole) developed retinal detachment. There was an overall hyperopic shift with a mean biometry error of 0.45 +/- 1.21 D in all eyes. The mean absolute biometry prediction error was 0.98 +/- 0.83 D in all eyes, 1.11 +/- 0.86 D and 0.85 +/- 0.82 D in eyes receiving negative- and positive-power IOL, respectively (p = 0.042). A total of 61.2 % of eyes had refractive outcome within +/- 1.0 D of target spherical equivalent. Regression analysis showed low IOL power as an independent predictor for greater postoperative absolute biometry error (p = 0.014). We showed no increase in perioperative complications in eyes with extreme high axial myopia. In eyes with long axial length, implantation of IOL with lower power was associated with more hyperopic shift, which was more pronounced with negative-power IOL.
引用
收藏
页码:1811 / 1817
页数:7
相关论文
共 32 条
[1]   Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods [J].
Abulafia, Adi ;
Barrett, Graham D. ;
Rotenberg, Michael ;
Kleinmann, Guy ;
Levy, Adi ;
Reitblat, Olga ;
Koch, Douglas D. ;
Wang, Li ;
Assia, Ehud I. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03) :548-556
[3]   B-mode-guided vector-A-mode versus A-mode biometry to determine axial length and intraocular lens power [J].
Berges, O ;
Puech, M ;
Assouline, M ;
Letenneur, L ;
Gastellu-Etchegorry, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) :529-535
[4]  
Chong EW, 2015, CURR OPIN OPHTHALMOL, DOI 10.1097/icu.0000000000000217
[5]   Posterior vitreous detachment and retinal detachment following cataract extraction [J].
Coppe, Andrea M. ;
Lapucci, Giuliana .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (03) :239-242
[6]   Incidence, Risk Factors, and Impact of Age on Retinal Detachment after Cataract Surgery in France A National Population Study [J].
Daien, Vincent ;
Le Pape, Annick ;
Heve, Didier ;
Carriere, Isabelle ;
Villain, Max .
OPHTHALMOLOGY, 2015, 122 (11) :2179-2185
[7]   The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications [J].
Day, A. C. ;
Donachie, P. H. J. ;
Sparrow, J. M. ;
Johnston, R. L. .
EYE, 2015, 29 (04) :552-560
[8]  
Fan DS, 1999, OPHTHALMOLOGY, V106, P688, DOI [10.1016/s0161-6420(99)90152-5, DOI 10.1016/S0161-6420(99)90152-5]
[9]  
Fan DS, 1999, OPHTHALMOLOGY, V106, P691, DOI [10.1016/s0161-6420(99)90152-5, DOI 10.1016/S0161-6420(99)90152-5,]
[10]   Prevalence, incidence, and progression of myopia of school children in Hong Kong [J].
Fan, DSP ;
Lam, DSC ;
Lam, RF ;
Lau, JTF ;
Chong, KS ;
Cheung, EYY ;
Lai, RYK ;
Chew, SJ .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (04) :1071-1075