Mapping the collateral network: Optimal near-infrared spectroscopy optode placement

被引:8
作者
von Aspern, Konstantin [1 ,2 ]
Haunschild, Josephina [1 ,2 ]
Khachatryan, Zara [1 ,2 ]
Simoniuk, Urszula [1 ,2 ]
Ossmann, Susann [1 ]
Borger, Michael A. [1 ]
Etz, Christian D. [1 ,2 ]
机构
[1] Heart Ctr Leipzig, Univ Dept Cardiac Surg, Leipzig, Germany
[2] Univ Leipzig, Saxonian Incubator Clin Translat, Leipzig, Germany
关键词
collateral network; near-infrared spectroscopy; cnNIRS; ischemic spinal cord injury; thoracoabdominal aorta; noninvasive monitoring; large animal model; THORACIC AORTIC PROCEDURES; SPINAL-CORD OXYGENATION; ANEURYSM REPAIR; ISCHEMIA; INJURY; IMPACT;
D O I
10.1016/j.jtcvs.2020.07.103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Paraplegia after extensive aortic procedures is a disastrous complication, and maintenance of adequate spinal cord perfusion/oxygenation is pivotal to its prevention. Collateral network (CN) near-infrared spectroscopy (cnNIRS) has been introduced as a noninvasive method for indirect spinal cord oxygenation monitoring. However, the CN has not been investigated in its entirety using this monitoring modality. This study aimed to identify the optimal cnNIRS positioning in an acute large animal model for routine clinical use. Methods: The paraspinous CN was measured from the high thoracic region to the low lumbar region (T4-L5) using cnNIRS in 10 juvenile pigs (plus reference data from 7 animals) during aortic ischemia and reperfusion. These data were compared with data on direct regional tissue perfusion of the CN and the spinal cord. Results: After aortic cross-clamping, cnNIRS at the mid-thoracic to the low lumbar level decreased rapidly to a nadir at 10 minutes of distal ischemia (mean difference, 18.3 +/- 11% to 44.5 +/- 9%; P < .001 to .045), with more pronounced changes in the caudal regions. High thoracic cnNIRS remained stable (mean difference, 4.3 +/- 4%; P = .915). Measurements of cnNIRS, CN, and spinal cord regional perfusion demonstrated comparable curve progressions starting from the mid-thoracic region (r = 0.5-0.7; P < (.)001). Conclusions: cnNIRS is capable of detecting relevant changes during ischemia and reperfusion from the mid-thoracic level downward with characteristic oxygenation patterns corresponding to CN and spinal cord regional perfusion. For extensive aortic procedures, noninvasive cnNIRS placement appears to be useful from the mid-thoracic level (T7-T9) to the lower lumbar level (L3-L5) and also may serve as a versatile monitoring method for procedures limited to the proximal thoracic aorta.
引用
收藏
页码:E3 / E15
页数:13
相关论文
共 28 条
[1]   Skin to cervical epidural space distances as read from magnetic resonance imaging films: Consideration of the "hump pad" [J].
Aldrete, JA ;
Mushin, AU ;
Zapata, JC ;
Ghaly, R .
JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (04) :309-313
[2]  
[Anonymous], 2013, J Spinal Cord Med, V36, P394, DOI 10.1179/1079026813Z.000000000196
[3]  
[Anonymous], 2011, ANIM RES GUIDE CARE
[4]   Spinal Near-Infrared Spectroscopy Measurements During and After Thoracoabdominal Aortic Aneurysm Repair: A Pilot Study [J].
Boezeman, Reinout P. E. ;
van Dongen, Eric P. ;
Morshuis, Wim J. ;
Sonker, Uday ;
Boezeman, Eduard H. J. F. ;
Waanders, Frans G. J. ;
de Vries, Jean-Paul P. M. .
ANNALS OF THORACIC SURGERY, 2015, 99 (04) :1267-1274
[5]   Outcomes of 3309 thoracoabdominal aortic aneurysm repairs [J].
Coselli, Joseph S. ;
LeMaire, Scott A. ;
Preventza, Ourania ;
de la Cruz, Kim I. ;
Cooley, Denton A. ;
Price, Matt D. ;
Stolz, Alan P. ;
Green, Susan Y. ;
Arredondo, Courtney N. ;
Rosengart, Todd K. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (05) :1323-1337
[6]   Commentary: Toward safer aortic surgery: Monitoring spinal cord perfusion with near-infrared spectroscopy [J].
Crestanello, Juan A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01) :165-166
[7]   Direct health care costs after traumatic spinal cord injury [J].
Dryden, DM ;
Saunders, LD ;
Jacobs, P ;
Schopflocher, DP ;
Rowe, BH ;
May, LA ;
Yiannakoulias, N ;
Svenson, LW ;
Voaklander, DC .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (02) :441-447
[8]   Near-infrared Spectroscopy Monitoring of the Collateral Network Prior to, During, and After Thoracoabdominal Aortic Repair: A Pilot Study [J].
Etz, C. D. ;
von Aspern, K. ;
Gudehus, S. ;
Luehr, M. ;
Girrbach, F. F. ;
Ender, J. ;
Borger, M. ;
Mohr, F. W. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (06) :651-656
[9]   Spinal cord blood flow and ischemic injury after experimental sacrifice of thoracic and abdominal segmental arteries [J].
Etz, Christian D. ;
Homann, Tobias M. ;
Luehr, Maximilian ;
Kari, Fabian A. ;
Weisz, Donald J. ;
Kleinman, George ;
Plestis, Konstadinos A. ;
Griepp, Randall B. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (06) :1030-1037
[10]   The collateral network concept: Remodeling of the arterial collateral network after experimental segmental artery sacrifice [J].
Etz, Christian D. ;
Kari, Fabian A. ;
Mueller, Christoph S. ;
Brenner, Robert M. ;
Lin, Hung-Mo ;
Griepp, Randall B. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04) :1029-1036