Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire

被引:6
作者
Machida, Haruhiko [1 ]
Komori, Yoshiaki [2 ]
Ueno, Eiko [1 ]
Shen, Yun [1 ]
Hirata, Masami [1 ]
Kojima, Shinya [1 ]
Sato, Munekuni [1 ,3 ]
Okazaki, Takeshi [4 ]
Masukawa, Ai
Morita, Satoru [1 ]
Suzuki, Kazufumi [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Radiol, Med Ctr E, Arakawa Ku, Tokyo 1168567, Japan
[2] Siemens Asahi Med Technol, Tokyo, Japan
[3] Fuyo Corp, Tokyo, Japan
[4] Goodman Co, Nagoya, Aichi, Japan
关键词
Intraluminal Doppler guidewire; Phantom experiment; Phase-contrast cine magnetic resonance imaging; Pulsatile flow velocity quantification; BREATH-HOLD; NONINVASIVE DETERMINATION; CORONARY ANGIOPLASTY; RESERVE; HUMANS; WIRE; QUANTIFICATION; ULTRASOUND; AGREEMENT; ARTERIES;
D O I
10.1007/s11604-010-0472-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the accuracy of magnetic resonance imaging (MRI) measurements of pulsatile flow velocity in a small tube phantom using different spatial factors versus those obtained by intraluminal Doppler guidewire examination (as reference). We generated pulsatile flow velocities averaging about 20-290 cm/sec in a tube of 4 mm diameter; we performed phase-contrast cine MRI on pixels measuring 1.00(2)-2.50(2) mm(2). We quantified spatial peak flow velocities of a single pixel and a cluster of five pixels and spatial mean velocities within regions of interest enclosing the entire lumen in the phantom's cross-section. Finally, we compared the measurements of temporally mean and maximum flow velocity with the Doppler measurements. Linear correlation was excellent between both measurements of spatial peak flow velocities in one pixel. The highest spatial resolution using spatial peak flow velocities of a single pixel allowed the most accurate MRI measurements of both temporally mean and maximum pulsatile flow velocity (r = 0.97 and 0.99, respectively: MRI measurement = 0.95x + 8.9 and 0.88x + 24.0 cm/s, respectively). Otherwise, MRI measurements were significantly underestimated at lower spatial resolutions. High spatial resolution allowed accurate MRI measurement of temporally mean and maximum pulsatile flow velocity at spatial peak velocities of one pixel.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 32 条
[1]   Accuracy of segmented MR velocity mapping to measure small vessel pulsatile flow in a phantom simulating cardiac motion [J].
Arheden, H ;
Saeed, M ;
Törnqvist, E ;
Lund, G ;
Wendland, MF ;
Higgins, CB ;
Ståhlberg, F .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) :722-728
[2]   Magnetic resonance imaging versus Doppler guide wire in the assessment of coronary flow reserve in patients with coronary artery disease [J].
Bedaux, WLF ;
Hofman, MBM ;
de Cock, CC ;
Stoel, MG ;
Visser, CA ;
van Rossum, AC .
CORONARY ARTERY DISEASE, 2002, 13 (07) :365-372
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Clinical blood flow quantification with segmented k-space magnetic resonance phase velocity mapping [J].
Chatzimavroudis, GP ;
Zhang, HS ;
Halliburton, SS ;
Moore, JR ;
Simonetti, OP ;
Schvartzman, PR ;
Stillman, AE ;
White, RD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (01) :65-71
[5]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[6]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[7]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703
[8]   Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients - Physiologic investigation for transplant arteriopathy (PITA study) [J].
Fearon, WF ;
Nakamura, M ;
Lee, DP ;
Rezaee, M ;
Vagelos, RH ;
Hunt, SA ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 108 (13) :1605-1610
[9]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[10]   Assessment of coronary arterial flow and flow reserve in humans with magnetic resonance imaging [J].
Hundley, WG ;
Lange, RA ;
Clarke, GD ;
Meshack, BM ;
Payne, J ;
Landau, C ;
McColl, R ;
Sayad, DE ;
Willett, DL ;
Willard, JE ;
Hillis, LD ;
Peshock, RM .
CIRCULATION, 1996, 93 (08) :1502-1508