Assessment of Sensations Experienced by Subjects during MR Imaging Examination at 7T

被引:12
|
作者
Uwano, Ikuko [1 ]
Metki, Tsuyoshi [1 ]
Sendai, Fusako [1 ]
Yoshida, Ryoko [1 ]
Kudo, Kohsuke [1 ,2 ]
Yamashita, Fumio [1 ]
Higuchi, Satomi [1 ]
Ito, Kenji [1 ]
Harada, Taisuke [1 ,2 ]
Goodwin, Jonathan [1 ,2 ]
Ogawa, Akira [3 ]
Sasaki, Makoto [1 ]
机构
[1] Iwate Med Univ, Inst Biomed Sci, Div Ultrahigh Field MRI, Yahaba, Iwate 0283694, Japan
[2] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, Sapporo, Hokkaido, Japan
[3] Iwate Med Univ, Dept Neurosurg, Morioka, Iwate, Japan
关键词
magnetic resonance imaging; side effects; subject acceptance; ultra high field; 7; tesla; MAGNETIC-FIELD; EXPOSURE; SAFETY; PERCEPTION;
D O I
10.2463/mrms.2014-0004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated sensations experienced by a large number of subjects during magnetic resonance (MR) imaging examinations using a 7-tesla scanner and slow table-feed speed. Methods: After examinations at 7T, 504 of 508 consecutive subjects completed questionnaires using an 11-point scale to rate 14 potential sensations and symptoms during table movement and stationary positioning of the table. We compared scores among the sensations and between table conditions and the mean values of the scores with those reported in previous studies and examined correlations between the scores and subject characteristics. Results: Vertigo and feelings of curving or leaning in the right or left direction during table movement were experienced frequently and markedly compared to other sensations and sensations experienced when the table was stationary (P < 0.01) and were correlated with subject age and examination time (P < 0.05). However, moderate to severe (scores of 5 to 10) vertigo and a curving/leaning feeling during table movement were noted in only 10.5% (vertigo) and 10.9% (curving/leaning) of subjects, and the mean vertigo score, 1.26, appeared to be substantially lower than that reported in a previous study. Reports of a metallic taste, nausea, and light flashes were significantly rarer and weaker than other sensations (P < 0.05). Conclusion: Vertigo and feelings of curving during table movement were the most frequent sensations reported during MR imaging examination at 7T. However, the occurrence and severity were low and mild, presumably because of the slow table-feed speed, which suggests that most patients and volunteers found discomfort at 7T acceptable.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Safety for Human MR Scanners at 7T
    Okada, Tomohisa
    Akasaka, Thai
    Thuy, Dinh H. D.
    Isa, Tadashi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (04) : 531 - 537
  • [2] Rapid in vivo musculoskeletal MR with parallel imaging at 7T
    Banerjee, Suchandrima
    Krug, Roland
    Carballido-Gamio, Julio
    Kelley, Douglas A. C.
    Xu, Duan
    Vigneron, Daniel B.
    Majumdar, Sharmila
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 655 - 660
  • [3] Shielded Microstrip Array for 7T Human MR Imaging
    Wu, Bing
    Wang, Chunsheng
    Kelley, Douglas A. C.
    Xu, Duan
    Vigneron, Daniel B.
    Nelson, Sarah J.
    Zhang, Xiaoliang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 179 - 184
  • [4] 7T Imaging of the Wrist
    Friedrich, Klaus M.
    Komorowski, Arkadiusz
    Trattnig, Siegfried
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2012, 16 (02) : 88 - 92
  • [5] An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T
    Kim, Kyoung-Nam
    Han, Sang-Doc
    Seo, Jeung-Hoon
    Heo, Phil
    Yoo, Dongkyeom
    Im, Geun Ho
    Lee, Jung Hee
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 253 - 258
  • [6] Flexible metasurface for improving brain imaging at 7T
    Koloskov, Vladislav
    Brink, Wyger M.
    Webb, Andrew G.
    Shchelokova, Alena
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 869 - 880
  • [7] Short-term effects experienced during examinations in an actively shielded 7 T MR
    Hansson, Boel
    Hoglund, Peter
    Bloch, Karin Markenroth
    Nilsson, Markus
    Olsrud, Johan
    Wilen, Jonna
    Bjorkman-Burtscher, Isabella M.
    BIOELECTROMAGNETICS, 2019, 40 (04) : 234 - 249
  • [8] MR-safety in clinical practice at 7T: Evaluation of a multistep screening process in 1819 subjects
    Hansson, B.
    Simic, M.
    Olsrud, J.
    Bloch, K. Markenroth
    Owman, T.
    Sundgren, P. C.
    Bjorkman-Burtscher, I. M.
    RADIOGRAPHY, 2022, 28 (02) : 454 - 459
  • [9] Assessing a Dysplastic Cerebellar Gangliocytoma (Lhermitte-Duclos Disease) with 7T MR Imaging
    Moenninghoff, Christoph
    Kraff, Oliver
    Schlamann, Marc
    Ladd, Mark E.
    Katsarava, Zaza
    Gizewski, Elke R.
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (02) : 244 - 248
  • [10] 7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging
    Yan, Xinqiang
    Zhang, Xiaoliang
    Feng, Baotong
    Ma, ChuangXin
    Wei, Long
    Xue, Rong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (09) : 1781 - 1787