Amplified Anodic Electrogenerated Chemiluminescence of Tris(2,2′-bipyridyl)ruthenium(II) for the Sensitive Detection of Isatin

被引:9
作者
Abdussalam, Abubakar [1 ,2 ,3 ]
Guan, Yiran [1 ]
Xu, Guobao [1 ,2 ]
机构
[1] Chinese Acad Sci, State Key Lab Elctroanalyt Chem, Changchun Inst Appl Chem, 5625 Renmin St, Changchun 130022, Jilin, Peoples R China
[2] Univ Sci & Technol China, Sch Appl Chem & Engn, Hefei 230026, Anhui, Peoples R China
[3] Bayero Univ, Fac Sci, Dept Chem, PMB 3011, Kano, Nigeria
基金
中国国家自然科学基金;
关键词
isatin; electrochemiluminescence; co-reactant; ortho-quinone; chemiluminescence; ELECTROCHEMILUMINESCENCE; URINE; DERIVATIVES; ELECTRODE; CARBON;
D O I
10.1002/celc.201902148
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Isatin is an endogenous indole derivative that has been reported to possess various pharmacological and therapeutic activities of clinical importance. To date, isatin has been detected mainly by mass spectrometry. Here, we report for the first time the intense anodic electrochemiluminescence (ECL) of tris(2,2 '-bipyridyl)ruthenium(II) with isatin as an efficient co-reactant. Interestingly, the ECL response of the Ru(bpy)(3)(2+)/isatin system in borate buffer solution is about 12 times more intense than in phosphate buffer of the same pH; and approximately 114 times greater than the ECL intensity of the luminophore. Under the optimal conditions, the ECL of Ru(bpy)(3)(2+) increases linearly with the concentration of the isatin in the range of 1.0 mu M to 1.0 mM (R-2=0.998) with a limit of detection (LOD) of 0.28 mu M (3 sigma/m). Moreover, the method has been successfully applied to the detection of isatin in human urine. The developed method has shown excellent recoveries in the range of 99.7-101.3 %. The anodic ECL assay reported in this work is superior in terms of linear range and selectivity than the previously reported methods and can be applied for the detection of isatin in real samples.
引用
收藏
页码:1207 / 1212
页数:6
相关论文
共 33 条
  • [1] Abdussalam A., 2020, J ELECTROANAL CHEM, DOI 10 .1016/j.jelechem.2019.113752
  • [2] THE EFFECT OF BORATE BUFFER ON ORTHO QUINONE ELECTROCHEMISTRY
    BAILEY, SI
    RITCHIE, IM
    [J]. ELECTROCHIMICA ACTA, 1987, 32 (07) : 1027 - 1033
  • [3] Oxindoles and copper complexes with oxindole-derivatives as potential pharmacological agents
    Cerchiaro, Giselle
    da Costa Ferreira, Ana Maria
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (08) : 1473 - 1485
  • [4] Tris(2,2'-bipyridyl)ruthenium(II)-Nanomaterial Co-Reactant Electrochemiluminescence
    Chen, Lichan
    Wei, Jingjing
    Chi, Yuwu
    Zhou, Shu-Feng
    [J]. CHEMELECTROCHEM, 2019, 6 (15): : 3878 - 3884
  • [5] Electrochemical behaviour of isatin at a glassy carbon electrode
    Diculescu, Victor C.
    Kumbhat, Sunita
    Oliveira-Brett, Ana Maria
    [J]. ANALYTICA CHIMICA ACTA, 2006, 575 (02) : 190 - 197
  • [6] Isatin Detection Using a Boron-Doped Diamond 3-in-1 Sensing Platform
    Ensch, Mary
    Maldonado, Vanessa Y.
    Swain, Greg M.
    Rechenberg, Robert
    Becker, Michael F.
    Schuelke, Thomas
    Rusinek, Cory A.
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1951 - 1958
  • [7] A single-electrode electrochemical system for multiplex electrochemiluminescence analysis based on a resistance induced potential difference
    Gao, Wenyue
    Muzyka, Kateryna
    Ma, Xiangui
    Lou, Baohua
    Xu, Guobao
    [J]. CHEMICAL SCIENCE, 2018, 9 (16) : 3911 - 3916
  • [8] ISATIN IS A POTENT ENDOGENOUS ANTAGONIST OF GUANYLATE CYCLASE-COUPLED ATRIAL-NATRIURETIC-PEPTIDE RECEPTORS
    GLOVER, V
    MEDVEDEV, A
    SANDLER, M
    [J]. LIFE SCIENCES, 1995, 57 (22) : 2073 - 2079
  • [9] Mechanism study on inhibited Ru(bpy)32+ electrochemiluminescence between coreactants
    Guo, Longhua
    Xue, Lingling
    Qiu, Bin
    Lin, Zhenyu
    Kim, Donghwan
    Chen, Guonan
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (39) : 12826 - 12832
  • [10] HAMAUE N, 1994, BIOGENIC AMINES, V10, P99