Aerosol Generation and Mitigation During Methacholine Bronchoprovocation Testing: Infection Control Implications in the Era of COVID-19

被引:6
作者
Subat, Yosuf W. [1 ]
Hainy, Matthew E. [2 ]
Torgerud, Keith D. [3 ]
Sajgalik, Pavol [4 ]
Guntupalli, Siva Kamal [1 ]
Johnson, Bruce D. [4 ]
Chul-Ho, Kim [4 ]
Lim, Kaiser G. [1 ]
Helgeson, Scott A. [5 ]
Scanlon, Paul D. [1 ]
Niven, Alexander S. [1 ]
机构
[1] Mayo Clin, Dept Med, Div Pulm Crit Care & Sleep Med, Rochester, MN 55905 USA
[2] Mayo Clin, Div Engn, Rochester, MN 55905 USA
[3] Mayo Clin, Resp Care & Cardiopulm Diagnost, La Crosse, WI USA
[4] Mayo Clin, Dept Cardiol, Human Integrat & Environm Physiol Lab, Rochester, MN 55905 USA
[5] Mayo Clin, Dept Med, Div Pulm & Crit Care Med, Jacksonville, FL 32224 USA
关键词
Methacholine; Aerosol; Droplet; COVID-19; SARS-CoV-2; Infection Control; Asthma; NEBULIZER OUTPUT; CHALLENGE; INHALATION; DOSIMETER; DELIVERY; ASTHMA;
D O I
10.4187/respcare.09236
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Methacholine bronchoprovocation or challenge testing (MCT) is commonly performed to assess airway hyper-responsiveness in the setting of suspected asthma. Nebulization is an aerosol-generating procedure, but little is known about the risks of MCT in the context of the ongoing coronavirus disease 2019 (COV1D-19) pandemic. We aimed to quantify and characterize aerosol generMien during MCT by using different delivery methods and to assess the impact of adding a viral filter. METHODS: Seven healthy subjects performed simulated MCT in a near particle-free laboratory space with 4 different nehulizers and with a dosimeter. Two devices continuously sampled the ambient air during the procedure, which detected ultrafine particles, from 0.02-1 mu m, and particles of sizes 03, 0.3, 1.0, 2.0, 5.0, and 10 mu m, respectively. Particle generation was compared among all the devices, with and without viral filter placement. RESULTS: Ultrafine-particle generation during simulated MCT was significant across all the devices. Ultrafine-particle (0.02-1 mu m) concentrations decreased 77%-91% with the addition of a viral filter and varied significantly between unfiltered (P < .001) and filtered devices (P < .001). Ultrafine-particle generation was lowest when using the dosimeter with filtered Hudson nebulizer (1,258 +/- 1,644 particle/mL). Ultrafine-particle concentrations with the filtered nebulizer devices using a compressor were higher than particle concentrations detected when using the dosimeter: Monaghan (3,472 +/- 1,794 particles/mL), PARI (4,403 +/- 2,948), Hudson (6,320 +/- 1,787) and AirLife (9,523 +/- 5,098). CONCLUSIONS: The high particle concentrations generated during MCT pose significant infection control concerns during the COVID-19 pandemic. Particle generation during MCT was significantly reduced by using breath-actuated delivery and a viral filter, which offers an effective mitigation strategy.
引用
收藏
页码:1858 / 1865
页数:8
相关论文
共 50 条
  • [21] Aerosol Production with Surgical Instrumentation: Implications for Head and Neck Surgery in the COVID-19 Era
    Low, Garren M. I.
    LeConte, Bailey
    Eguia, Arturo A.
    Kim, Ashley
    Karni, Ron J.
    Luong, Amber U.
    Jain, Kunal S.
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2022, 74 (SUPPL 2) : 3145 - 3150
  • [22] COVID-19 infection rates and mitigation strategies in orthodontic practices
    Durbin, Peter M.
    Viana, Grace
    Allareddy, Veerasathpurush
    Kusnoto, Budi
    Ravindran, Sriram
    Kadkol, Shrihari
    Atsawasuwan, Phimon
    BMC ORAL HEALTH, 2023, 23 (01)
  • [23] Infection Control Practices in Orthodontics during COVID-19
    Ejaz, Zainab
    Azeem, Muhammad
    Bukhari, Fareeha
    Ghani, Muhammad Usman
    Rashid, Abdul
    Sha, Ammad Ayub
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (06): : 1345 - 1346
  • [24] COVID-19 infection rates and mitigation strategies in orthodontic practices
    Peter M Durbin
    Grace Viana
    Veerasathpurush Allareddy
    Budi Kusnoto
    Sriram Ravindran
    Shrihari Kadkol
    Phimon Atsawasuwan
    BMC Oral Health, 23
  • [25] Reimagining Infection Control in US Nursing Homes in the Era of COVID-19
    Crnich, Christopher J.
    JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2022, 23 (12) : 1909 - 1915
  • [26] Asthma management and control during COVID-19 pandemic
    Zayen, Khalil
    Snene, Houda
    Blibech, Hana
    Fenina, Wafa
    El Wadhane, Israa
    Maalej, Mariem
    Jebali, Aymen
    Daghfous, Jalloul
    Mehiri, Nadia
    Ben Salah, Nozha
    Louzir, Bechir
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [27] COVID-19 in Dental Practice: Transmission Risk, Infection Control Challenge, and Clinical Implications
    Aldahlawi, Salwa A.
    Afifi, Ibtesam K.
    OPEN DENTISTRY JOURNAL, 2020, 14 : 348 - 354
  • [28] COVID-19: Mitigation Strategies and Their Implications for the Global Environment
    He, Lei
    Hu, Qunfang
    Liu, Zhongmin
    Zhang, Ying
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 10
  • [29] Autopsy assessment of pediatric head injury: a proposal for aerosol mitigation during the COVID-19 pandemic
    Emma C. Cheshire
    Roger D. G. Malcomson
    Guy N. Rutty
    Forensic Science, Medicine and Pathology, 2021, 17 : 498 - 500
  • [30] Autopsy assessment of pediatric head injury: a proposal for aerosol mitigation during the COVID-19 pandemic
    Cheshire, Emma C.
    Malcomson, Roger D. G.
    Rutty, Guy N.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2021, 17 (03) : 498 - 500