Automated Electrokinetic Platform for High-Throughput Sodium Dodecyl Sulfate Depletion Ahead of Proteome Analysis by Mass Spectrometry

被引:2
作者
Jakubec, Philip J. [1 ]
Doucette, Alan A. [1 ]
机构
[1] Dalhousie Univ, Dept Chem, Halifax, NS B3H 4R2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
SAMPLE PREPARATION METHOD; SDS DEPLETION; REMOVAL; SURFACTANT; DIGESTION; PROTEINS; SEPARATION;
D O I
10.1021/acs.analchem.1c03549
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sodium dodecyl sulfate (SDS) provides numerous benefits for proteome sample preparation. However, the surfactant can be detrimental to downstream mass spectrometry analysis. Although strategies are available to deplete SDS from proteins, each is plagued by unique deficiencies that challenge their utility for high-throughput proteomics. An optimal approach would rapidly and reproducibly achieve less than 10 ppm residual SDS while simultaneously maximizing analyte recovery. Here, we describe improvements to a simple electrokinetic device termed transmembrane electrophoresis, which we previously reported for automated, rapid SDS depletion of proteome samples. Voltagedriven transport of SDS across a molecular weight cutoff membrane is enhanced at higher electric fields, which is herein achieved by integrating an active cooling mechanism to mitigate the impacts of Joule heating. We report 99.9% reduction of SDS (final concentration < 5 ppm) in 5 min. The device is employed in a detergent-based proteomic workflow for analysis of an enriched yeast membrane proteome extract, demonstrating quantitative protein recovery (>98%) and increasing the number of identifications by liquid chromatography-tandem mass spectrometry.
引用
收藏
页码:14042 / 14047
页数:6
相关论文
共 31 条
  • [21] Online Integration of Multiple Sample Pretreatment Steps Involving Denaturation, Reduction, and Digestion with Microflow Reversed-Phase Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry for High-Throughput Proteome Profiling
    Ma, Junfeng
    Liu, Jinxiang
    Sun, Liangliang
    Gao, Liang
    Liang, Zhen
    Zhang, Lihua
    Zhang, Yukui
    ANALYTICAL CHEMISTRY, 2009, 81 (15) : 6534 - 6540
  • [22] Optimization of a Differential Ion Mobility Spectrometry-Tandem Mass Spectrometry Method for High-Throughput Analysis of Nicotine and Related Compounds: Application to Electronic Cigarette Refill Liquids
    Regueiro, Jorge
    Giri, Anupam
    Wenzl, Thomas
    ANALYTICAL CHEMISTRY, 2016, 88 (12) : 6500 - 6508
  • [23] Specific and high-resolution identification of monoclonal antibody fragments detected by capillary electrophoresis-sodium dodecyl sulfate using reversed-phase HPLC with top-down mass spectrometry analysis
    Wang, Wei-Han
    Cheung-Lau, Jasmina
    Chen, Yan
    Lewis, Michael
    Tang, Qing Mike
    MABS, 2019, 11 (07) : 1233 - 1244
  • [24] Rapid and high-throughput determination of cationic surfactants in environmental water samples by automated on-line polymer monolith microextraction coupled to high performance liquid chromatography-mass spectrometry
    Peng, Xi-Tian
    Shi, Zhi-Guo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (23) : 3588 - 3594
  • [25] High-throughput quantitative analysis of domoic acid directly from mussel tissue using Laser Ablation Electrospray Ionization - tandem mass spectrometry
    Beach, Daniel G.
    Walsh, Callee M.
    McCarron, Pearse
    TOXICON, 2014, 92 : 75 - 80
  • [26] High-Throughput Cell and Tissue Analysis with Enhanced Molecular Coverage by Laser Ablation Electrospray Ionization Mass Spectrometry Using Ion Mobility Separation
    Shrestha, Bindesh
    Vertes, Akos
    ANALYTICAL CHEMISTRY, 2014, 86 (09) : 4308 - 4315
  • [27] Fabrication of magnetic magnesium oxide cleanup adsorbent for high-throughput pesticides residue analysis coupled with supercritical fluid chromatography-tandem mass spectrometry
    Qi, Peipei
    Wang, Jiao
    Liu, Zhenzhen
    Wang, Zhiwei
    Di, Shanshan
    Zhao, Huiyu
    Wang, Xinquan
    ANALYTICA CHIMICA ACTA, 2023, 1265
  • [28] Sulfonyl hydrazine-functionalized polymer as a specific capturer of reducing glycans from complex samples for high-throughput analysis by electrospray ionization mass spectrometry
    Wang, Chengjian
    Yuan, Jiangbei
    Li, Xiaohua
    Wang, Zhongfu
    Huang, Linjuan
    ANALYST, 2013, 138 (18) : 5344 - 5356
  • [29] Automated, High-Throughput Phenotypic Screening and Analysis Platform to Study Pre- and Post-Implantation Morphogenesis in Stem Cell-Derived Embryo-Like Structures
    Shankar, Vinidhra
    van Blitterswijk, Clemens
    Vrij, Erik
    Giselbrecht, Stefan
    ADVANCED SCIENCE, 2024, 11 (04)
  • [30] metAlignID: A high-throughput software tool set for automated detection of trace level contaminants in comprehensive LECO two-dimensional gas chromatography time-of-flight mass spectrometry data
    Lommen, Arjen
    van der Kamp, Henk J.
    Kools, Harrie J.
    van der Lee, Martijn K.
    van der Weg, Guido
    Mol, Hans G. J.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1263 : 169 - 178