Detection of Monosodium Urate Crystals for Gout Diagnosis Using Magnetic Fields and Near-Infrared Light

被引:6
作者
Takeuchi, Yuka [1 ]
Iwasaka, Masakazu [2 ]
机构
[1] Muroran Inst Technol, Muroran, Hokkaido 0508585, Japan
[2] Hiroshima Univ, Res Inst Nanodevice & Bio Syst, Higashihiroshimashi 7398527, Japan
关键词
Diamagnetic material; gout diagnosis; magnetic field; magnetic orientation. monosodium urate (MSU) crystal; DUAL-ENERGY CT; TOPHACEOUS GOUT; COMPUTED-TOMOGRAPHY; SODIUM URATE; DISEASE; ULTRASONOGRAPHY; SPECTROSCOPY; MONOHYDRATE; DEPOSITION;
D O I
10.1109/TMAG.2016.2529061
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gouty arthritis is caused by hyperuricemia, and it can develop even when the serum urate level is controlled. Methods to recognize and identify symptoms include polarization microscopy, X-ray imaging, dual-energy computed tomography, magnetic resonance imaging, and ultra-sonography. However, each method has disadvantages, such as not meeting the need for early diagnosis. Hence, no satisfactory method has been established, and alternatives to measuring serum urate levels are desired. Because monosodium urate (MSU) crystals can be rotated by applied magnetic fields, we investigated a method to noninvasively detect the crystals in vivo using magnetic fields and near-infrared light. Because near-infrared light passes through the human body, diagnosis of gout can be performed noninvasively from outside the body. MSU crystals that are equal in size to those accumulated in the human body were prepared in calf serum. Magnetically induced changes in reflected near-infrared light intensity were measured with a spectrophotometer. Specifically, 800-850 nm reflected light intensity changed 5% at 300 mT. Therefore, it may be possible to detect the existence of MSU crystals for the diagnosis of gout by using near-infrared light and a magnetic field.
引用
收藏
页数:4
相关论文
共 26 条
[1]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[2]   Imaging in gout: insights into the pathological features of disease [J].
Dalbeth, Nicola ;
Doyle, Anthony ;
McQueen, Fiona M. .
CURRENT OPINION IN RHEUMATOLOGY, 2012, 24 (02) :132-138
[3]   Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout [J].
Desai, Madhura A. ;
Peterson, Jeffrey J. ;
Garner, Hillary Warren ;
Kransdorf, Mark J. .
RADIOGRAPHICS, 2011, 31 (05) :1365-1375
[4]   OPTICAL-PROPERTIES OF HUMAN-BRAIN TISSUE, MENINGES, AND BRAIN-TUMORS IN THE SPECTRAL RANGE OF 200 TO 900 NM [J].
EGGERT, HR ;
BLAZEK, V .
NEUROSURGERY, 1987, 21 (04) :459-464
[5]   THE CRYSTALLIZATION AND DISSOLUTION OF SODIUM URATE [J].
ERWIN, CYL ;
NANCOLLAS, GH .
JOURNAL OF CRYSTAL GROWTH, 1981, 53 (01) :215-223
[6]  
FAM AG, 1992, J RHEUMATOL, V19, P780
[7]   Imaging of tophaceous gout: computed tomography provides specific images compared with magnetic resonance imaging and ultrasonography [J].
Gerster, JC ;
Landry, M ;
Dufresne, L ;
Meuwly, JY .
ANNALS OF THE RHEUMATIC DISEASES, 2002, 61 (01) :52-54
[8]   Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation [J].
Glazebrook, Katrina N. ;
Guimaraes, Luis S. ;
Murthy, Naveen S. ;
Black, David F. ;
Bongartz, Tim ;
Manek, Nisha J. ;
Leng, Shuai ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOLOGY, 2011, 261 (02) :516-524
[9]   Crystal clear - Sonographic assessment of gout and calcium pyrophosphate deposition disease [J].
Grassi, W. ;
Meenagh, G. ;
Pascual, E. ;
Filippucci, E. .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 2006, 36 (03) :197-202
[10]   DETECTION OF DYNAMIC CHANGES IN CEREBRAL OXYGENATION COUPLED TO NEURONAL FUNCTION DURING MENTAL WORK IN MAN [J].
HOSHI, Y ;
TAMURA, M .
NEUROSCIENCE LETTERS, 1993, 150 (01) :5-8