2D-PIV measurement of range hood-driven flow in a domestic kitchen

被引:33
作者
Chen, Wenhua [1 ]
Li, Jiayu [1 ]
Wang, Congcong [1 ]
Dai, Xilei [1 ]
Liu, Junjie [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin, Peoples R China
关键词
PIV; Range hood; Domestic kitchen; Air distribution; Spill length; Vortex identification; AIR-QUALITY; THERMAL PLUMES; GAS COOKING; PERFORMANCE; EXPOSURE; DIFFUSER; FIELD; TEMPERATURE; APPLIANCES; PARTICLES;
D O I
10.1016/j.enbuild.2018.07.051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-performance range hoods can quickly exhaust cooking smoke and fumes outdoors. Quantifying the detailed information that range hood-driven flow provides can be an essential prerequisite to optimize the hood's performance. Direct measuring instruments cannot easily determine the velocity due to large velocity gradients and high temperatures. Particle image velocimetry (PIV) is a non-intrusive velocimeter-based method with high spatial resolution and in a global domain. Thus, we applied large-scale 20-Ply and measured the range hood-driven flow in three sections under isothermal and heating conditions. This study systematically investigated the influence of the exhaust flow rate and mounting height on the range hood-driven flow. The measurement results under isothermal conditions show the actual airflow driven by a range hood cannot be characterized as a simple exhaust and have self-similarity for different exhaust airflow rates. The results also indicate that the mounting height only slightly impacts the velocity boundary conditions of the range hood exhaust surface. The results under the heating conditions clearly reveal that the time-averaged spill length is larger than the average value of the dynamic spill length. This phenomenon indicates that the relationship between time-averaged velocity fields and spill length is not a simple linear scaling relationship. The unsteady flow in the kitchen should be considered to determine the true capture efficiency. Moreover, uncertainty analysis ensures that the benchmark flow data for the follow-up kitchen environment and range hood design simulations. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 76
页数:13
相关论文
共 48 条
[1]   Numerical investigation of the flow in a kitchen hood system [J].
Abanto, J ;
Reggio, M .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :288-296
[2]  
[Anonymous], 1997, ASHRAE T
[3]  
[Anonymous], 2011, 177132011 GBT INSP Q
[4]  
[Anonymous], 2012, F170412 ANSIASTM TBT
[5]  
ASHRAE, 2007, 621 ASHRAE
[6]   Ultrafine particle concentrations and exposures in seven residences in northern California [J].
Bhangar, S. ;
Mullen, N. A. ;
Hering, S. V. ;
Kreisberg, N. M. ;
Nazaroff, W. W. .
INDOOR AIR, 2011, 21 (02) :132-144
[7]   Do air quality targets really represent safe limits for lung cancer risk? [J].
Buonanno, G. ;
Stabile, L. ;
Morawska, L. ;
Giovinco, G. ;
Querol, X. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 580 :74-82
[8]  
Cao CS, 2017, INDOOR BUILT ENVIRON, V26, P226, DOI [10.1177/1420326x16673215, 10.1177/1420326X16673215]
[9]   2D-PIV measurement of isothermal air jets from a multi-slot diffuser in aircraft cabin environment [J].
Cao, Xiaodong ;
Li, Jiayu ;
Liu, Junjie ;
Yang, William .
BUILDING AND ENVIRONMENT, 2016, 99 :44-58
[10]   2D-PIV measurement of aircraft cabin air distribution with a high spatial resolution [J].
Cao, Xiaodong ;
Liu, Junjie ;
Pei, Jingjing ;
Zhang, Yun ;
Li, Jiayu ;
Zhu, Xueliang .