Thrombin activity in CSP after SAH is correlated with the degree of SAH, the persistence of subarachnoid clot and the development of vasospasm

被引:41
作者
Kasuya, H [1 ]
Shimizu, T [1 ]
Takakura, K [1 ]
机构
[1] Tokyo Womens Med Coll, Dept Neurosurg, Shinjuku Ku, Tokyo 162, Japan
关键词
fibrinopeptide; subarachnoid haemorrhage; thrombin; vasospasm;
D O I
10.1007/s007010050143
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We previously reported that the coagulation system in cerebrospinal fluid (CSF) is strongly activated in the early stage of a subarachnoid haemorrhage (SAH). We evaluated the relationship among thrombin activity, degree of SAH, amount of clearance of SAH, and vasospasm. The CSF levels of fibrinopeptide A (FPA) were measured by radio-immunoassay in 36 SAH patients, who were diagnosed by computerized tomography (CT) within 12 hours and on whom surgery was performed within 48 hours. Clearance of SAH (%) was evaluated as the size of the clot in the basal cistern visualized between the initial and postoperative Cf. The mean level of FPA. in the patients of Group 3 (Fisher's CT classification) (182.2 ng/ml) was significantly higher than those in the patients of Group 2 (36.2 ng/ml). There was a significant difference in the mean level of FPA between patients with (47.6 ng/ml) and without infarction (408.3 ng/ml). In 18 of the 27 patients of Group 3 for whom the clearance of the SAH was determined, the patients showing a lower clearance rate (<50%) of SAH demonstrated a significantly higher rate of infarction and a significantly higher level of FPA (466.6 ng/ml) than did the patients with a higher clearance rate (>50%) of SAH (79.2 ng/ml). These results suggest that, the thrombin activity in CSF is correlated with the degree of SAH, the persistence of subarachnoid clot and the development of vasospasm.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 16 条
[1]   INFARCTION AFTER ANEURYSM RUPTURE DOES NOT DEPEND ON DISTRIBUTION OR CLEARANCE RATE OF BLOOD [J].
BROUWERS, PJAM ;
WIJDICKS, EFM ;
VANGIJN, J .
STROKE, 1992, 23 (03) :374-379
[2]   RELATION OF CEREBRAL VASOSPASM TO SUBARACHNOID HEMORRHAGE VISUALIZED BY COMPUTERIZED TOMOGRAPHIC SCANNING [J].
FISHER, CM ;
KISTLER, JP ;
DAVIS, JM .
NEUROSURGERY, 1980, 6 (01) :1-9
[3]   THE VALUE OF COMPUTERIZED-TOMOGRAPHY IN ANEURYSMAL SUBARACHNOID HEMORRHAGE - THE CONCEPT OF THE CT SCORE [J].
GURUSINGHE, NT ;
RICHARDSON, AE .
JOURNAL OF NEUROSURGERY, 1984, 60 (04) :763-770
[4]   THE USE OF COMPUTED-TOMOGRAPHY IN THE PREDICTION OF DELAYED CEREBRAL INFARCTION FOLLOWING ACUTE ANEURYSM SURGERY FOR SUBARACHNOID HEMORRHAGE [J].
HIRASHIMA, Y ;
KURIMOTO, R ;
TAKABA, M ;
ENDO, S ;
TAKAKU, A .
ACTA NEUROCHIRURGICA, 1995, 132 (1-3) :9-13
[5]   SURGICAL RISK AS RELATED TO TIME OF INTERVENTION IN REPAIR OF INTRACRANIAL ANEURYSMS [J].
HUNT, WE ;
HESS, RM .
JOURNAL OF NEUROSURGERY, 1968, 28 (01) :14-&
[6]   ACTIVATION OF THE COAGULATION SYSTEM IN THE SUBARACHNOID SPACE AFTER SUBARACHNOID HEMORRHAGE - SERIAL MEASUREMENT OF FIBRINOPEPTIDE-A AND BRADYKININ OF CEREBROSPINAL-FLUID AND PLASMA IN PATIENTS WITH SUBARACHNOID HEMORRHAGE [J].
KASUYA, H ;
SHIMIZU, T ;
OKADA, T ;
TAKAHASHI, K ;
SUMMERVILLE, T ;
KITAMURA, K .
ACTA NEUROCHIRURGICA, 1988, 91 (3-4) :120-125
[7]   ACTIVATED COMPLEMENT COMPONENTS C3A AND C4A IN CEREBROSPINAL-FLUID AND PLASMA FOLLOWING SUBARACHNOID HEMORRHAGE [J].
KASUYA, H ;
SHIMIZU, T .
JOURNAL OF NEUROSURGERY, 1989, 71 (05) :741-746
[8]   THE RELATION OF CEREBRAL VASOSPASM TO THE EXTENT AND LOCATION OF SUBARACHNOID BLOOD VISUALIZED BY CT SCAN - A PROSPECTIVE-STUDY [J].
KISTLER, JP ;
CROWELL, RM ;
DAVIS, KR ;
HEROS, R ;
OJEMANN, RG ;
ZERVAS, T ;
FISHER, CM .
NEUROLOGY, 1983, 33 (04) :424-436
[9]   MEASUREMENT IN HUMAN-BLOOD OF FIBRINOGEN FIBRIN FRAGMENTS CONTAINING THE B-BETA-15-42 SEQUENCE [J].
KUDRYK, B ;
ROBINSON, D ;
NETRE, C ;
HESSEL, B ;
BLOMBACK, M ;
BLOMBACK, B .
THROMBOSIS RESEARCH, 1982, 25 (03) :277-291
[10]   PREDICTION OF DELAYED CEREBRAL-ISCHEMIA AFTER SUBARACHNOID HEMORRHAGE BY COMPUTED-TOMOGRAPHY [J].
MOHSEN, F ;
POMONIS, S ;
ILLINGWORTH, R .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1984, 47 (11) :1197-1202