Treatment of aseptic non-union after intramedullary nailing without removal of the nail

被引:30
作者
Garnavos, Christos [1 ]
机构
[1] Evangelismos Gen Hosp, Orthopaed Dept, 45 Ipsilantou St, Athens 10676, Greece
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷
关键词
Non-union; Delayed union; Intramedullary nailing; Long bone fracture; Without nail removal; Nail retention; Ultrasound/electrical stimulation; Nail dynamisation; Biological stimulation; Augmentation plating; AUGMENTATION PLATE FIXATION; FEMORAL-SHAFT NONUNION; TIBIAL NONUNION; ELECTRICAL-STIMULATION; IN-SITU; BONE; EXCHANGE; FRACTURES; COMPRESSION; MANAGEMENT;
D O I
10.1016/j.injury.2017.04.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Failure of bone healing after intramedullary nailing of a diaphyseal long bone fracture is a severe complication that requires an effective management to ensure the best chances for successful bone-union and termination of a long period of incapacity and morbidity for the sufferers. Traditional procedures require removal of the existing nail and re-fixation with wider nail, plate or external fixation constructs. The concept that bone union can be obtained with the existing nail in situ is gaining popularity as its removal adds trauma and potential complications and prolongs the operating time. This article reviews all techniques that have been proposed for the management of aseptic diaphyseal long bone non-unions that stimulate bone healing without removing the existing nail. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S76 / S81
页数:6
相关论文
共 65 条
[1]  
[Anonymous], EUR J TRAUMA EMERG S
[2]   Exchange reamed nailing compared to augmentation compression plating leaving the inserted nail in situ in the treatment of aseptic tibial non-union: a two-centre study [J].
Ateschrang, Atesch ;
Karavalakis, Georgios ;
Gonser, Christoph ;
Liener, Ulrich ;
Freude, Thomas ;
Stoeckle, Ulrich ;
Walcher, Matthias ;
Zieker, Derek .
WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 (9-10) :244-253
[3]   High Success Rate for Augmentation Compression Plating Leaving the Nail In Situ for Aseptic Diaphyseal Tibial Nonunions [J].
Ateschrang, Atesch ;
Albrecht, Dirk ;
Stoeckle, Ulrich ;
Weise, Kuno ;
Stuby, Fabian ;
Zieker, Derek .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (03) :145-149
[4]  
Azzam W, 2016, EUR J ORTHOP SURG TR
[5]   Nonunion of the diaphysis of long bones [J].
Babhulkar, S ;
Pande, K ;
Babhulkar, S .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (431) :50-56
[6]  
Bassett C A, 1978, Acta Orthop Belg, V44, P706
[7]  
Bhargava Rakesh, 2007, Indian J Orthop, V41, P67, DOI 10.4103/0019-5413.30529
[8]  
Birjandinejad A, 2009, ORTHOPEDICS, V32, P409, DOI [10.3928/01477447-20090511-12, 10.3928/01477447-20090922-23]
[9]   A MULTI-CENTER STUDY OF THE TREATMENT OF NON-UNION WITH CONSTANT DIRECT-CURRENT [J].
BRIGHTON, CT ;
BLACK, J ;
FRIEDENBERG, ZB ;
ESTERHAI, JL ;
DAY, LJ ;
CONNOLLY, JF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (01) :2-13
[10]  
Brinker MR, 2007, J BONE JOINT SURG AM, V89A, P177, DOI 10.2106/JBJS.F.00742