Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:30
|
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 50 条
  • [31] Comparison of Strut Coverage at 6 Months by Optical. Coherence Tomography With Everolimus-Eluting Stenting of Bare-Metal Stent Restenosis Versus Stenosis of Nonstented Atherosclerotic Narrowing (from the DESERT Study)
    Picchi, Andrea
    Musumeci, Giuseppe
    Calabria, Paolo
    Cresti, Alberto
    Rescigno, Roberto
    Aruffo, Alessandra
    Prati, Francesco
    Limbruno, Ugo
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (10): : 1351 - 1356
  • [32] Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial
    Gutierrez-Chico, Juan Luis
    van Geuns, Robert Jan
    Regar, Evelyn
    van der Giessen, Willem J.
    Kelbaek, Henning
    Saunamaki, Kari
    Escaned, Javier
    Gonzalo, Nieves
    di Mario, Carlo
    Borgia, Francesco
    Nueesch, Eveline
    Garcia-Garcia, Hector M.
    Silber, Sigmund
    Windecker, Stephan
    Serruys, Patrick W.
    EUROPEAN HEART JOURNAL, 2011, 32 (19) : 2454 - 2463
  • [33] Optical coherence tomography study of chronic-phase vessel healing after implantation of bare metal and paclitaxel-eluting self-expanding nitinol stents in the superficial femoral artery
    Kozuki, Amane
    Shinke, Toshiro
    Otake, Hiromasa
    Kijima, Yoichi
    Masano, Tomoya
    Nagoshi, Ryoji
    Imamura, Kimitake
    Fujiwara, Ryudo
    Shibata, Hiroyuki
    Takeshige, Ryo
    Tsukiyama, Yoshiro
    Yanaka, Kenichi
    Nakano, Shinsuke
    Fukuyama, Yusuke
    Kawashima, Seinosuke
    Hirata, Ken-ichi
    Shite, Junya
    JOURNAL OF CARDIOLOGY, 2016, 67 (5-6) : 424 - 429
  • [34] 10-Year Follow-Up of Patients With Everolimus-Eluting Versus Bare-Metal Stents After ST-Segment Elevation Myocardial Infarction
    Brugaletta, Salvatore
    Gomez-Lara, Josep
    Ortega-Paz, Luis
    Jimenez-Diaz, Victor
    Jimenez, Marcelo
    Jimenez-Quevedo, Pilar
    Diletti, Roberto
    Mainar, Vicente
    Campo, Gianluca
    Silvestro, Antonio
    Maristany, Jaume
    Flores, Xacobe
    Oyarzabal, Loreto
    De Miguel-Castro, Antonio
    Iniguez, Andres
    Serra, Antonio
    Nombela-Franco, Luis
    Ielasi, Alfonso
    Tespili, Maurizio
    Lenzen, Mattie
    Gonzalo, Nieves
    Bordes, Pascual
    Tebaldi, Matteo
    Biscaglia, Simone
    Rodriguez-Arias, Juan Jose
    Al-Shaibani, Soheil
    Arevalos, Victor
    Romaguera, Rafael
    Gomez-Hospital, Joan Antoni
    Serruys, Patrick W.
    Sabate, Manel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (09) : 1165 - 1178
  • [35] Favorable early vessel healing after everolimus-eluting stent implantation: 3-, 6-, and 12-month follow-up of optical coherence tomography
    Konishi, Akihide
    Iwasaki, Masamichi
    Shinke, Toshiro
    Otake, Hiromasa
    Takaya, Tomofumi
    Osue, Tsuyoshi
    Nishio, Ryo
    Kinutani, Hiroto
    Kuroda, Masaru
    Takahashi, Hachidai
    Terashita, Daisuke
    Shite, Junya
    Hirata, Ken-ichi
    JOURNAL OF CARDIOLOGY, 2018, 72 (3-4) : 193 - 199
  • [36] Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study
    Kim, Jung-Sun
    Fan, Chunyu
    Choi, Donghoon
    Jang, Ik-Kyung
    Lee, Jung Myung
    Kim, Tae Hoon
    Park, Sang Min
    Paik, Sung Il
    Ko, Young-Guk
    Hong, Myeong-Ki
    Jang, Yangsoo
    Chung, Namsik
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (03) : 341 - 346
  • [37] A Novel Polymer-Free Ciglitazone-Eluting Stent Inhibits Neointimal Proliferation Stronger than Sirolimus-Eluting Stents: An Experimental Study Using Optical Coherence Tomography in Rabbit Iliacal Arteries
    Poerner, Tudor C.
    Otto, Sylvia
    Bischoff, Sabine
    Muehlstaedt, Diana
    Goebel, Bjoern
    Jung, Christian
    Figulla, Hans R.
    CIRCULATION, 2010, 122 (21)
  • [38] Serial Angioscopic Evaluation of Neointimal Coverage and Incidence of Thrombus Formation After Paclitaxel-Eluting Stent Implantation: Comparison Between 6-and 18-Month Follow-Up
    Hara, Masahiko
    Nishino, Masami
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CLINICAL CARDIOLOGY, 2011, 34 (05) : 322 - 326
  • [39] The Unrestricted Use of Sirolimus- and Paclitaxel-Eluting Stents Results in Better Clinical Outcomes During 6-Years Follow-up than Bare-Metal Stents. An analysis of the RESEARCH and T-SEARCH registries.
    Simsek, Cihan
    Magro, Michael
    Boersma, Eric
    Onuma, Yoshinobu
    Nauta, Sjoerd
    Gaspersz, Marcia
    van der Giessen, Willem
    van Domburg, Ron
    Serruys, Patrick
    CIRCULATION, 2010, 122 (21)
  • [40] Impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent: five-year follow-up optical coherence tomography study
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Shinozaki, Tomohiro
    Jinnouch, Hiroyuki
    Muraoka, Yoshitaka
    Domei, Takenori
    Hyodo, Makoto
    Shirai, Shinichi
    Ando, Kenji
    Otsuji, Yutaka
    HEART AND VESSELS, 2018, 33 (04) : 341 - 350