Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:30
|
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 50 条
  • [1] Six-month follow-up evaluation for everolimus-eluting stents by intracoronary optical coherence tomography: Comparison with paclitaxel-eluting stents
    Takano, Masamichi
    Murakami, Daisuke
    Yamamoto, Masanori
    Kurihara, Osamu
    Murai, Koji
    Inami, Toru
    Kimata, Nakahisa
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 181 - 186
  • [2] Everolimus-Eluting Versus Paclitaxel-Eluting Stents for Treatment of Bare Metal Stent Restenosis
    Almalla, Mohammad
    Schroeder, Joerg W.
    Pross, Verena
    Stegemann, Emilia
    Marx, Nikolaus
    Hoffmann, Rainer
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (04): : 518 - 522
  • [3] Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    EUROINTERVENTION, 2015, 11 (05) : 564 - 571
  • [4] Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
    Matsumoto, Daisuke
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Paredes, Oscar Luis
    Hirata, Ken-ichi
    Yokoyama, Mitsuhiro
    EUROPEAN HEART JOURNAL, 2007, 28 (08) : 961 - 967
  • [5] A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS trial): rationale, design and methods
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Janiak, Florian
    Danzer, Constance
    Ferrari, Markus
    Figulla, Hans R.
    EUROINTERVENTION, 2011, 7 : K93 - K99
  • [6] Comparison by Optical Coherence Tomography of Paclitaxel-Eluting Stents With Sirolimus-Eluting Stents Implanted in One Coronary Artery in One Procedure - 6-Month Follow-up
    Miyoshi, Naoki
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Kawamori, Hiroyuki
    Kato, Hiroki
    Yoshino, Naoki
    Kozuki, Amane
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2010, 74 (05) : 903 - 908
  • [7] Comparison of Neointimal Coverage of Sirolimus-Eluting Stents and Paclitaxel-Eluting Stents Using Optical Coherence Tomography at 9 Months After Implantation
    Kim, Jin-Sun
    Kim, Jung-Sun
    Kim, Tae Hoon
    Fan, Chunyu
    Lee, Jung Myung
    Kim, Woong
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    CIRCULATION JOURNAL, 2010, 74 (02) : 320 - 326
  • [8] Predictors of Stent Thrombosis after Everolimus-Eluting and Paclitaxel-Eluting Stents: The Pooled SPIRIT Randomized Trial Experience at Two Years of Follow-Up
    Kirtane, Ajay
    Sood, Poornima
    Applegate, Robert J.
    Yaqub, Manejeh
    Onuma, Yoshinobu
    Wang, John C.
    Su, Xiaolu
    Miquel-Hebert, Karine
    Lansky, Alexandra J.
    Kereiakes, Dean J.
    Simonton, Charles A.
    Sudhir, Krishnankutty
    Serruys, Patrick W.
    Stone, Gregg W.
    CIRCULATION, 2010, 122 (21)
  • [9] Serial Changes of Neointimal Coverage Condition and Characteristic are Different between Sirolimus-Eluting Stents, Paclitaxel-Eluting Stents and Zotalolimus-Eluting Stents Implantation: Follow-Up Optical Coherence Tomography Study
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)
  • [10] Serial Changes of Neointimal Coverage Conditions and Characteristics are different between Sirolimus-Eluting Stents and Paclitaxel-Eluting Stents Implantation: Follow-Up Optical Coherence Tomography Study
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)