Polymer-free amphilimus-eluting stent versus biodegradable polymer biolimus-eluting stent in patients with and without diabetes mellitus

被引:12
作者
Godino, Cosmo [1 ]
Pivato, Carlo Andrea [1 ]
Chiarito, Mauro [2 ]
Donahue, Michael [3 ]
Testa, Luca [4 ]
Colantonio, Riccardo [5 ]
Cappelletti, Alberto [1 ]
Milazzo, Diego [6 ]
Parisi, Rosario [7 ]
Nicolino, Annamaria [8 ]
Moshiri, Shahram [8 ]
Aprigliano, Gianfranco [9 ]
Palloshi, Altin [9 ]
Parenti, Dennis Zavalloni [2 ]
Rutigliano, David [10 ]
Locuratolo, Nicola [10 ]
Melillo, Francesco [1 ]
Scotti, Andrea [1 ]
Arrigoni, Luca [1 ]
Montorfano, Matteo [1 ]
Fattori, Rossella [7 ]
Presbitero, Patrizia [2 ]
Sardella, Gennaro [11 ]
Bedogni, Francesco [4 ]
Margonato, Alberto [1 ]
Briguori, Carlo [3 ]
Colombo, Antonio [1 ,12 ]
机构
[1] Ist Sci San Raffaele, Milan, Italy
[2] Humanitas Clin Inst, Milan, Italy
[3] Clin Mediterranea, Naples, Italy
[4] IRCCS Policlin San Donato, Milan, Italy
[5] Osped San Pietro FBF, Rome, Italy
[6] Osped San Giovanni Dio, Agrigento, Italy
[7] Osped Riuniti Marche Nord, Pesaro, Italy
[8] Osped Santa Corona, Pietra Ligure, Italy
[9] Ist Clin Citta Studi, Milan, Italy
[10] Osped San Paolo, Bari, Italy
[11] Univ Roma La Sapienza, Policlin Umberto I, Rome, Italy
[12] EMO GVM Ctr Cuore Columbus, Milan, Italy
关键词
Diabetes mellitus; Percutaneous coronary intervention; Polymer-free amphilimus eluting stent; Biodegradable polymer biolimus eluting stent; PERCUTANEOUS CORONARY INTERVENTION; 5-YEAR CLINICAL-OUTCOMES; DURABLE POLYMER; ASTUTE REGISTRY; POOLED ANALYSIS; EVEROLIMUS; POPULATION; RESTENOSIS; INSIGHT; DISEASE;
D O I
10.1016/j.ijcard.2017.06.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study sought to compare clinical outcome of polymer-free amphilimus-eluting stent (PF-AES) versus biodegradable-polymer biolimus- eluting stent (BD-BES) in "all-comer" diabetes mellitus (DM) and non-DM patients who underwent percutaneous coronary intervention. Background: The PF-AES has shown promising preliminary results in patients with DM. Methods: Data from 2 multicentre-national registries (the ASTUTE and the INSPIRE-1) were used to analyse 1776 patients stratified in non-DM and DM. A double 1: 1 propensity-score matched analysis (PF-AES vs. BD-BES) was performed in each group to adjust for clinical and procedural characteristics. Primary stent-efficacy and stentsafety endpoints were 1-year target-lesion revascularization (TLR) and target-lesion failure (TLF, composed of cardiac-death, target-vessel myocardial infarction and any TLR). Results: After propensity-score matching, 850 patients were stratified as non-DM (425 PF-AES/425 BD-BES) and 480 as DM patients (240 PF-AES/240BD-BES). Both TLF (20 of 425 [5%] vs. 24 of 425 [ 6%]; Plog-rank = 0.527) and TLR (9 of 425 [2%] vs. 18 of 425 [4%]; Plog-rank= 0.079) were similar between PF-AES and BD-BES in non-DM patients. In DM, TLF (12 of 240 [5%] vs. 31 of 240 [13%]; Plog-rank= 0.002) and TLR (9 of 240 [4%] vs. 21 of 240 [9%]; Plog-rank= 0.019) were significantly lower in PF-AES compared to BD-BES. Upon multivariate analysis, the most powerful predictors of TLF were chronic kidney disease in non-DM (OR 4.24, 95% CI: 2.07-8.70, p = 0.001) and stent type in DM patients (OR 2.76, 1.36-5.56, p = 0.005). Conclusions: This matched-cohort study suggests that PF-AES has better safety and efficacy profile than BD-BES in patients with DM. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 48 条
[1]  
Amer Diabet Assoc, 2018, DIABETES CARE, V41, pS13, DOI [10.2337/dc19-S002, 10.2337/dc18-S002, 10.2337/dc09-S062, 10.2337/dc12-S064]
[2]  
[Anonymous], 1988, STAT POWER ANAL BEHA, DOI DOI 10.1234/12345678
[3]   The Adverse Long-Term Impact of Renal Impairment in Patients Undergoing Percutaneous Coronary Intervention in the Drug-Eluting Stent Era [J].
Appleby, Clare E. ;
Ivanov, Joan ;
Lavi, Shahar ;
Mackie, Karen ;
Horlick, Eric M. ;
Ing, Douglas ;
Overgaard, Christopher B. ;
Seidelin, Peter H. ;
von Harsdorf, Ruediger ;
Dzavik, Vladimir .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) :309-U63
[4]   Optimal caliper widths for propensity-score matching when estimating differences in means and differences in proportions in observational studies [J].
Austin, Peter C. .
PHARMACEUTICAL STATISTICS, 2011, 10 (02) :150-161
[5]   Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent [J].
Awata, Masaki ;
Uematsu, Masaaki ;
Sera, Fusako ;
Ishihara, Takayuki ;
Watanabe, Tetsuya ;
Fujita, Masashi ;
Onishi, Toshinari ;
Iida, Osamu ;
Ishida, Yoshio ;
Nanto, Shinsuke ;
Nagata, Seiki .
CIRCULATION JOURNAL, 2011, 75 (05) :1113-1119
[6]   Variable selection for propensity score models [J].
Brookhart, M. Alan ;
Schneeweiss, Sebastian ;
Rothman, Kenneth J. ;
Glynn, Robert J. ;
Avorn, Jerry ;
Sturmer, Til .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2006, 163 (12) :1149-1156
[7]  
Byrne R A, 2009, Minerva Cardioangiol, V57, P567
[8]   A Multicenter Randomized Trial Comparing Amphilimus-With Paclitaxel-Eluting Stents in De Novo Native Coronary Artery Lesions [J].
Carrie, Didier ;
Berland, Jacques ;
Verheye, Stefan ;
Hauptmann, Karl Eugen ;
Vrolix, Mathias ;
Violini, Roberto ;
Dibie, Alain ;
Berti, Sergio ;
Maupas, Eric ;
Antoniucci, David ;
Schofer, Joachim .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (15) :1371-1376
[9]   Protein-mediated Fatty Acid Uptake in the Heart [J].
Chabowski, Adrian ;
Gorski, Jan ;
Glatz, Jan F. C. ;
Luiken, Joost J. F. P. ;
Bonen, Arend .
CURRENT CARDIOLOGY REVIEWS, 2008, 4 (01) :12-21
[10]  
Chevalier Bernard, 2007, EuroIntervention, V2, P426