The Reverse phase HPLC method was developed for simultaneous determination of Silodosin and Tadalafil in single analytical method. Chromatographic separation was achieved on a Supelco C8 (150mmx4.6mm, 5 mu m) column applying an isocratic elution based on premix of potassium phosphate dibasic buffer pH (4.3) and acetonitrile in the ratio of ( 70:30 v/v) as mobile. Validation parameters specificity, precision and robustness have been observed to be desirable over the concentration ranges of 80-240 mu g/ml for Silodosin and 50-150 mu g/ml for Tadalafil in accuracy parameter and 128-192 mu g/ml for Silodosin and 80-120 mu g/ml for Tadalafil in linearity parameter. All the variables have been studied to optimize the chromatographic conditions. The optimized approach verified through validation and confirmed to be intended purpose for the quality control of the mentioned drugs, as per ICH guidelines. For simultaneous quantification of Silodosin and Tadalafil, the developed method was found to be genuinely exact precise, accurate, linear, fast and cost effective.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 2017, PROD INF AUSPAR UR S
[2]   Validation and Method Development of Tadalafil in Bulk and Tablet Dosage Form by RP-HPLC [J].
Bojanapu, A. ;
Subramaniam, A. T. ;
Munusamy, J. ;
Dhanapal, K. ;
Chennakesavalu, J. ;
Sellappan, M. ;
Jayaprakash, V. .
DRUG RESEARCH, 2015, 65 (02) :82-85
[3]   Silodosin Causes Impaired Ejaculation and Enlargement of Seminal Vesicles in Sexually Active Men Treated for Lower Urinary Tract Symptoms Suggestive of Benign Prostatic Hyperplasia [J].
Bozkurt, Ozan ;
Demir, Omer ;
Sen, Volkan ;
Esen, Adil .
UROLOGY, 2015, 85 (05) :1085-1089
[4]  
Coward Robert M, 2008, Ther Clin Risk Manag, V4, P1315
[5]   An effective and sensitive stability-indicating chromatographic approach based on HPLC for silodosin assay [J].
Er, Engin ;
Erk, Nevin .
JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2016, 7
[6]   Simultaneous Determination of Sildenafil and Tadalafil in Legal Drugs, Illicit/Counterfeit Drugs, and Wastewater Samples by High-Performance Liquid Chromatography [J].
Fidan, Ali Kemal ;
Bakirdere, Sezgin .
JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (04) :923-928
[7]  
Ghadge O, 2015, DETERMINATION SOLUBI, V4, P1370
[8]  
Ks N, 2020, J DRUG METABOLISM TO, P1
[9]   Quality control techniques for routine analysis with liquid chromatography in laboratories [J].
Masson, Pierre .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) :168-173
[10]  
Nickerson B, 2008, FORMULATION ANAL DEV, P239, DOI [10.1002/9780470386361.ch10, DOI 10.1002/9780470386361.CH10]