Embolization after percutaneous coronary intervention in acute coronary syndrome Saphenous vein grafts versus native coronary arteries

被引:0
作者
Karakyriou, M. [1 ]
Hadjimiltiades, S. [1 ]
Meditskou, S. [2 ]
Nenopoulou, E. [3 ]
Efthimiadis, G. [1 ]
Vogazianos, P. [4 ]
Karvounis, C. [1 ]
Styliadis, I. [1 ]
机构
[1] Aristotle Univ Thessaloniki, AHEPA Hosp, Dept Cardiol, GR-54006 Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Lab Histol & Embryol, GR-54006 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Dept Pathol, GR-54006 Thessaloniki, Greece
[4] Univ Cyprus, Dept Comp Sci, CY-1678 Nicosia, Cyprus
关键词
Acute coronary syndrome; Embolization; Stent implantation; Saphenous vein grafts; Native coronary artery; MYOCARDIAL-INFARCTION; DISTAL PROTECTION; EMBOLIC PROTECTION; RANDOMIZED-TRIAL; CK-MB; ELEVATION; EVENTS; PERFUSION; INSIGHTS; INJURY;
D O I
10.1007/s00059-014-4184-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the occurrence of distal embolization and to quantify the amount of embolic material captured during stent implantation in native coronary arteries, as compared with saphenous vein grafts (SVG) in patients at different time periods after an acute coronary syndrome. In all, 104 patients presenting with unstable or stable angina underwent percutaneous coronary intervention (PCI) in 107 vessels and stent implantation in 112 lesions, 53 % of which were in SVG. Device deployment and retrieval was successful in 111 lesions. Embolic material was detected in 74 % of the protection devices. Early PCI, during a 2-week period after the last ischemic episode, was associated with larger embolic load, especially in the right coronary artery. The length of the lesion was the only preprocedural independent variable that was found to be a significant predictor for the presence of emboli (p = 0.002). The stent diameter and the maximum dilatation pressure were the two procedural variables found to be significant predictors for the presence of emboli (p = 0.025 and p = 0.008, respectively). The irregularity of the lesion and the number of stents deployed were found to have a predictive correlation to the total area of the embolic particles (p = 0.04 and p = 0.005, respectively). Distal embolization of atherosclerotic debris is a frequent phenomenon after PCI not only in SVG but also in native vessels. The amount of embolic material seems to be related to the atherosclerotic burden of the vessel and to the early timing of the procedure as related to acute coronary syndrome.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 26 条
[2]   Distal protection with a filter device during coronary stenting in patients with stable and unstable angina [J].
Angelini, A ;
Rubartelli, P ;
Mistrorigo, F ;
Della Barbera, M ;
Abbadessa, F ;
Vischi, M ;
Thiene, G ;
Chierchia, S .
CIRCULATION, 2004, 110 (05) :515-521
[3]   Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290
[4]   Myonecrosis after revascularization procedures [J].
Califf, RM ;
Abdelmeguid, AE ;
Kuntz, RE ;
Popma, JJ ;
Davidson, CJ ;
Cohen, EA ;
Kleiman, NS ;
Mahaffey, KW ;
Topol, EJ ;
Pepine, CJ ;
Lipicky, RJ ;
Granger, CB ;
Harrington, RA ;
Tardiff, BE ;
Crenshaw, BS ;
Bauman, RP ;
Zuckerman, BD ;
Chaitman, BR ;
Bittl, JA ;
Ohman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :241-251
[5]   Impact of them, elevation of biochemical markers of myocardial damage on long-term mortality after percutaneous coronary intervention: results of the CK-MB and PCI study [J].
Cavallini, C ;
Savonitto, S ;
Violini, R ;
Arraiz, G ;
Plebani, M ;
Olivari, Z ;
Rubartelli, P ;
Battaglia, S ;
Niccoli, L ;
Steffenino, G ;
Ardissino, D .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1494-1498
[6]   Saphenous vein graft stenting and major adverse cardiac events - A predictive model derived from a pooled analysis of 3958 patients [J].
Coolong, Alanna ;
Baim, Donald S. ;
Kuntz, Richard E. ;
O'Malley, A. James ;
Marulkar, Sachin ;
Cutlip, Donald E. ;
Popma, Jeffrey J. ;
Mauri, Laura .
CIRCULATION, 2008, 117 (06) :790-797
[7]   Perfusion-contraction mismatch with coronary microvascular obstruction:: role of inflammation [J].
Dörge, H ;
Neumann, T ;
Behrends, M ;
Skyschally, A ;
Schulz, R ;
Kasper, C ;
Heusch, G .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (06) :H2587-H2592
[8]  
Dudek Dariusz, 2003, Przegl Lek, V60, P499
[9]  
El-Jack Seif S, 2007, J Interv Cardiol, V20, P474, DOI 10.1111/j.1540-8183.2007.00308.x
[10]   Randomized evaluation of the effects of filter-based distal protection on myocardial perfusion and infarct size after primary percutaneous catheter intervention in myocardial infarction with and without ST-segment elevation [J].
Gick, M ;
Jander, N ;
Bestehorn, HP ;
Kienzle, RP ;
Ferenc, M ;
Werner, K ;
Comberg, T ;
Peitz, K ;
Zohlnhöfer, D ;
Bassignana, V ;
Buettner, HJ ;
Neumann, FJ .
CIRCULATION, 2005, 112 (10) :1462-1469