Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture

被引:26
|
作者
Jiang, Xianbao [1 ]
Liang, Ke [1 ]
Du, Gang [2 ]
Chen, Yuan [1 ]
Tang, Yu [1 ]
Geng, Kuihua [1 ]
机构
[1] Guangxi Univ, Sch Mech Engn, Nanning 530004, Peoples R China
[2] Guangxi Med Univ, Affiliated Hosp 1, 6 Shuangyong Rd, Nanning 530004, Peoples R China
关键词
Femoral neck fracture fixation; Dynamic hip screw (DHS); Anti -rotation screw; Medial buttress plate; Finite element analysis; SLIDING HIP SCREW; WORLDWIDE PREVALENCE; CANNULATED SCREWS; ADULTS; CLASSIFICATION; COMPLICATIONS; DEVICES; SYSTEM;
D O I
10.1016/j.injury.2022.08.038
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and objective: The best internal fixation method for the treatment of Pauwels type III femoral neck fractures (FNFs) remains to be demonstrated. Through finite element analysis, this study explored whether dynamic hip screw (DHS) combined with anti rotation screw or medial buttress plate can im-prove the stability of internal fixation, and the femoral neck system (FNS) with similar structure to DHS and the traditional cannulated screw (CSs) were added for comparison. To evaluate their respective biomechanical advantages and disadvantages in the treatment of Pauwels type III FNFs.Methods: Six groups of internal fixation models for the treatment of FNFs were established, including CSs, DHS, DHS combined with single anti-rotation screw (DHS + SS), and DHS combined with both anti -rotation screw (DHS + BS), DHS combined with medial buttress plate (DHS + MBP), new femoral neck internal fixation system (Femoral Neck System, FNS). Four finite element analysis models were established for each group, evaluation of femoral displacement and internal fixation stress during stair climbing and walking conditions, and the contact force of the hip joint was used in two cases, dynamic and static.Results: The fracture plane motion and peak stress of internal fixators were the lowest with DHS + BS and CSs fixation, and the two results are very close, The peak value of DHS combined with anti rotation screw or medial buttress plate is much lower than that of DHS, indicating that the fixation effect of the combined model is enhanced, and there is no significant difference between FNS and DHS + SS.Conclusion: Both the anti rotation screw and medial buttress plate can effectively reduce the movement of fracture section and share the shear force of DHS, FNS has the similar fixation stability to DHS + SS, DHS + BS has the biomechanical advantages of significantly reducing the risk of internal fixation failure and femoral yield. Therefore, the use of DHS + BS may be a more favorable choice in the case of Pauwels type III FNFs with higher fixation requirements.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3115 / 3123
页数:9
相关论文
共 50 条
  • [1] Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture
    Lin Tianye
    Yang Peng
    Xu Jingli
    Wei QiuShi
    Zhou GuangQuan
    He Wei
    Zhang Qingwen
    BIOMEDICINE & PHARMACOTHERAPY, 2019, 112
  • [2] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ma, Ji
    Zhao, Ziying
    Zhi, Xiaodong
    Wang, Hao
    Wang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [3] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ji Ma
    Ziying Zhao
    Xiaodong Zhi
    Hao Wang
    Wei Wang
    BMC Musculoskeletal Disorders, 23
  • [4] Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods
    Cha, Yong-Han
    Yoo, Jun-Il
    Hwang, Seok-Young
    Kim, Kap-Jung
    Kim, Ha-Yong
    Choy, Won-Sik
    Hwang, Sun-Chul
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (01) : 1 - 14
  • [5] Biomechanical Study Using the Finite Element Method of Internal Fixation in Pauwels Type III Vertical Femoral Neck Fractures
    Noda, Mitsuaki
    Saegusa, Yasuhiro
    Takahashi, Masayasu
    Tezuka, Daichi
    Adachi, Kazuhiko
    Naoi, Kazuya
    ARCHIVES OF TRAUMA RESEARCH, 2015, 4 (03)
  • [6] Finite Element Analysis of Six Internal Fixations in the Treatment of Pauwels Type III Femoral Neck Fracture
    Sun, Xiang
    Han, Zhe
    Cao, Dongdong
    Han, Chao
    Xie, Mengqi
    Zeng, Xiantie
    Dong, Qiang
    ORTHOPAEDIC SURGERY, 2024, 16 (07) : 1695 - 1709
  • [7] Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture
    Teng, Yanbin
    Zhang, Yan
    Guo, Chaowei
    MEDICINE, 2022, 101 (28) : E29450
  • [8] Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane
    Ozer, Alaettin
    Oner, Kerim
    Okutan, Ahmet Emin
    Ayas, Muhammet Salih
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (02): : 352 - 358
  • [9] Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis
    Yonghan Cha
    Jun Young Chung
    Chang-Ho Jung
    Jin-Woo Kim
    Jeyoon Lee
    Jun-Il Yoo
    Jung-Taek Kim
    Yongho Jeon
    BMC Musculoskeletal Disorders, 24
  • [10] Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis
    Cha, Yonghan
    Chung, Jun Young
    Jung, Chang-Ho
    Kim, Jin-Woo
    Lee, Jeyoon
    Yoo, Jun-Il
    Kim, Jung-Taek
    Jeon, Yongho
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)