Collagen- versus gelatine-coated Dacron versus stretch PTFE bifurcation grafts for aortoiliac occlusive disease:: Long-term results of a prospective, randomized multicenter trial

被引:39
作者
Prager, MR
Hoblaj, T
Nanobashvili, J
Sporn, E
Polterauer, P
Wagner, O
Böhmig, HJ
Teufelsbauer, H
Ploner, M
Huk, I
机构
[1] Univ Vienna, Sch Med, Dept Vasc Surg, AKH, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Res Inst Interdisciplinary Vasc, Vienna, Austria
关键词
D O I
10.1067/msy.2003.179
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. In this prospective randomized multicenter trial, knitted gelatine-coated Dacron, knitted collagen-coated Dacron, and stretch poly tetrafluoroethylene (PTFE) aortic bifurcation grafts were compared for their long-term results. Methods. Between 1991 and 1998, 149 patients undergoing elective revascularization for aortoiliac occlusive disease were prospectively randomized at 3 tertiary referral centers of vascular surgery. The patients received either gelatine-coated Dacron (GEL-D) grafts (n = 52), collagen-coated Dacron (COLD) grafts (n = 49), or stretch PTFE grafts (n = 48). Results. No intraoperative deaths were recorded. The 30-day mortality was 4%. The mean follow-up time was 97 months. Primary patency rates were 77% for GEL-D, 78% for COL-D, and 79% for PTFE at 8 years. The differences were not different (P > .8). Secondary corrected 8-year patency rates were also not significantly different (P > .5): 91% for GEL-D, 96% for COL-Dm and 90% for PTFE. Five Dacron and 1 PTFE grafts were affected by infections. Conclusions. Bifurcation grafts for revascularization of aortoiliac occlusive disease using these 3 materials were comparable in terms. of primary and secondary patency and long-term complication rates.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 29 条
[1]  
AVRAMOV S, 1987, Journal of Cardiovascular Surgery, V28, P33
[2]  
AVRAMOV S, 1988, J CARDIOVASC SURG, V29, P6
[4]  
BURKE PM, 1987, J CARDIOVASC SURG, V28, P420
[5]  
CHIESA R, 1995, J CARDIOVASC SURG, V36, P135
[6]   A CLINICAL SURVEY OF AORTOBIFEMORAL BYPASS USING 2 INHERENTLY DIFFERENT GRAFT TYPES [J].
CINTORA, I ;
PEARCE, DE ;
CANNON, JA .
ANNALS OF SURGERY, 1988, 208 (05) :625-630
[7]   CARDIAC AND VASCULAR IMAGING WITH LABELED PLATELETS AND LEUKOCYTES [J].
DEWANJEE, MK .
SEMINARS IN NUCLEAR MEDICINE, 1984, 14 (03) :154-187
[8]   RESECTION OF AN ANEURYSM OF THE ABDOMINAL AORTA - REESTABLISHMENT OF THE CONTINUITY BY A PRESERVED HUMAN ARTERIAL GRAFT, WITH RESULT AFTER 5 MONTHS [J].
DUBOST, C ;
ALLARY, M ;
OECONOMOS, N .
AMA ARCHIVES OF SURGERY, 1952, 64 (03) :405-408
[9]   The 50th anniversary of abdominal aortic reconstruction [J].
Friedman, SG .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (04) :895-898
[10]   A PROSPECTIVE RANDOMIZED COMPARISON OF DACRON AND POLYTETRAFLUOROETHYLENE AORTIC BIFURCATION GRAFTS [J].
FRIEDMAN, SG ;
LAZZARO, RS ;
SPIER, LN ;
MOCCIO, C ;
TORTOLANI, AJ .
SURGERY, 1995, 117 (01) :7-10