On Factors Affecting Subharmonic-aided Pressure Estimation (SHAPE)

被引:25
作者
Gupta, Ipshita [1 ,2 ]
Eisenbrey, John R. [1 ]
Machado, Priscilla [1 ]
Stanczak, Maria [1 ]
Wallace, Kirk [3 ]
Forsberg, Flemming [1 ]
机构
[1] Thomas Jefferson Univ, Dept Radiol, 137 South 10th St,7 Main,Suite 763H, Philadelphia, PA 19107 USA
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[3] GE Global Res, Niskayuna, NY USA
关键词
ultrasound; acoustic power; subharmonic pressure estimation; optimization; hematocrit; contrast agent concentration; subharmonic imaging; ULTRASOUND CONTRAST AGENTS; BLOOD-MIMICKING FLUID; IN-VITRO; MICROBUBBLE SIGNALS; PORTAL-HYPERTENSION; BACKSCATTERING; SCATTERING;
D O I
10.1177/0161734618812083
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Subharmonic-aided pressure estimation (SHAPE) estimates hydrostatic pressure using the inverse relationship with subharmonic amplitude variations of ultrasound contrast agents (UCAs). We studied the impact of varying incident acoustic outputs (IAO), UCA concentration, and hematocrit on SHAPE. A Logiq 9 scanner with a 4C curvilinear probe (GE, Milwaukee, Wisconsin) was used with Sonazoid (GE Healthcare, Oslo, Norway) transmitting at 2.5 MHz and receiving at 1.25 MHz. An improved IAO selection algorithm provided improved correlations (r from -0.85 to -0.95 vs. -0.39 to -0.98). There was no significant change in SHAPE gradient as the pressure increased from 10 to 40 mmHg and hematocrit concentration was tripled from 1.8 to 4.5 mL/L (Delta 0.00-0.01 dB, p = 0.18), and as UCA concentration was increased from 0.2 to 1.2 mL/L (Delta 0.02-0.05 dB, p = 0.75). The results for the correlation between the SHAPE gradient and hematocrit values for patients (N = 100) in an ongoing clinical trial were also calculated showing a poor correlation value of 0.14. Overall, the SHAPE gradient is independent of hematocrit and UCA concentration. An improved algorithm for IAO selection will make SHAPE more accurate.
引用
收藏
页码:35 / 48
页数:14
相关论文
共 45 条
[1]   On the relationship between encapsulated ultrasound contrast agent and pressure [J].
Adam, D ;
Sapunar, M ;
Burla, E .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (05) :673-686
[2]   Measurement of portal pressure and its role in the management of chronic liver disease [J].
Bosch, Jaime ;
Garcia-Pagan, Juan Carlos ;
Berzigotti, Annalisa ;
Abraldes, Juan G. .
SEMINARS IN LIVER DISEASE, 2006, 26 (04) :348-362
[3]   Noninvasive measurement of the hydrostatic pressure in a fluid-filled cavity based on the disappearance time of micrometer-sized free gas bubbles [J].
Bouakaz, A ;
Frinking, PJA ;
de Jong, N ;
Bom, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1407-1415
[4]   Ultrasound contrast agents - Basic principles [J].
Calliada, F ;
Campani, R ;
Bottinelli, O ;
Bozzini, A ;
Sommaruga, MG .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 :S157-S160
[5]   Ultrasound contrast agents: An overview [J].
Cosgrove, David .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) :324-330
[6]   On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation [J].
Dave, J. K. ;
Halldorsdottir, V. G. ;
Eisenbrey, J. R. ;
Merton, D. A. ;
Liu, J. B. ;
Machado, P. ;
Zhao, H. ;
Park, S. ;
Dianis, S. ;
Chalek, C. L. ;
Thomenius, K. E. ;
Brown, D. B. ;
Forsberg, F. .
ULTRASONICS, 2013, 53 (04) :880-888
[7]   INVESTIGATING THE EFFICACY OF SUBHARMONIC AIDED PRESSURE ESTIMATION FOR PORTAL VEIN PRESSURES AND PORTAL HYPERTENSION MONITORING [J].
Dave, Jaydev K. ;
Halldorsdottir, Valgerdur G. ;
Eisenbrey, John R. ;
Merton, Daniel A. ;
Liu, Ji-Bin ;
Zhou, Jian-Hua ;
Wang, Hsin-Kai ;
Park, Suhyun ;
Dianis, Scott ;
Chalek, Carl L. ;
Lin, Feng ;
Thomenius, Kai E. ;
Brown, Daniel B. ;
Forsberg, Flemming .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (10) :1784-1798
[8]   Processing of Subharmonic Signals from Ultrasound Contrast Agents to Determine Ambient Pressures [J].
Dave, Jaydev K. ;
Halldorsdottir, Valgerdur G. ;
Eisenbrey, John R. ;
Forsberg, Flemming .
ULTRASONIC IMAGING, 2012, 34 (02) :81-92
[9]   Noninvasive LV Pressure Estimation Using Subharmonic Emissions From Microbubbles [J].
Dave, Jaydev K. ;
Halldorsdottir, Valgerdur G. ;
Eisenbrey, John R. ;
Raichlen, Joel S. ;
Liu, Ji-Bin ;
McDonald, Maureen E. ;
Dickie, Kris ;
Wang, Shumin ;
Leung, Corina ;
Forsberg, Flemming .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (01) :87-92
[10]   Noninvasive Estimation of Dynamic Pressures In Vitro and In Vivo Using the Subharmonic Response From Microbubbles [J].
Dave, Jaydev K. ;
Halldorsdottir, Valgerdur G. ;
Eisenbrey, John R. ;
Liu, Ji-Bin ;
McDonald, Maureen E. ;
Dickie, Kris ;
Leung, Corina ;
Forsberg, Flemming .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (10) :2056-2066