Anatomical Landmark Based Registration of Contrast Enhanced T1-Weighted MR Images

被引:0
作者
Demir, Ali [1 ]
Unal, Gozde [1 ]
Karaman, Kutlay [2 ]
机构
[1] Sabanci Univ, Istanbul, Turkey
[2] Anadolu Med Ctr, Kocaeli, Turkey
来源
BIOMEDICAL IMAGE REGISTRATION | 2010年 / 6204卷
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In many problems involving multiple image analysis, an image registration step is required. One such problem appears in brain tumor imaging, where baseline and follow-up image volumes from a tumor patient are often to-be compared. Nature of the registration for a change detection problem in brain tumor growth analysis is usually rigid or affine. Contrast enhanced T1-weighted MR images are widely used in clinical practice for monitoring brain tumors. Over this modality, contours of the active tumor cells and whole tumor borders and margins are visually enhanced. In this study, a new technique to register serial contrast enhanced T1 weighted MR images is presented. The proposed fully-automated method is based on five anatomical landmarks: eye balls, nose, confluence of sagittal sinus, and apex of superior sagittal sinus. After extraction of anatomical landmarks from fixed and moving volumes, an affine transformation is estimated by minimizing the sum of squared distances between the landmark coordinates. Final result is refined with a surface registration, which is based on head masks confined to the surface of the scalp, as well as to a plane constructed from three of the extracted features. The overall registration is not intensity based, and it depends only on the invariant structures. Validation studies using both synthetically transformed MRI data, and real MRI scans, which included several markers over the head of the patient were performed. In addition, comparison studies against manual landmarks marked by a radiologist, as well as against the results obtained from a typical mutual information based method were carried out to demonstrate the effectiveness of the proposed method.
引用
收藏
页码:91 / +
页数:3
相关论文
共 23 条
[1]  
ANGELINI E, 2007, CURRENT MED IMAGING, V3, P176
[2]  
CHRISTENSEN GE, 2004, IEEE INT S BIOM IM, V1, P591
[3]   A unified non-rigid feature registration method for brain mapping [J].
Chui, H ;
Win, L ;
Schultz, R ;
Duncan, JS ;
Rangarajan, A .
MEDICAL IMAGE ANALYSIS, 2003, 7 (02) :113-130
[4]   Image registration based on boundary mapping [J].
Davatzikos, C ;
Prince, JL ;
Bryan, RN .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (01) :112-115
[5]  
DAVATZIKOS C, 1994, IEEE WORKSH BIOM IM, P245
[6]  
DOUGLAS NG, 2009, NEUROIMAGE
[7]  
Ettinger G. J., 1994, Proceedings of the IEEE Workshop on Biomedical Image Analysis (Cat. No.94TH0624-7), P297, DOI 10.1109/BIA.1994.315885
[8]   Ill-posed medicine - an introduction to image registration [J].
Fischer, Bernd ;
Modersitzki, Jan .
INVERSE PROBLEMS, 2008, 24 (03)
[9]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[10]  
Golub G. H., 1996, MATRIX COMPUTATIONS