Analysis and optimization of passive cooling approach for free-standing photovoltaic panel: Introduction of slits

被引:30
作者
Marinic-Kragic, Ivo [1 ]
Nizetic, Sandro [2 ]
Grubisic-Cabo, Filip [2 ]
Coko, Duje [3 ]
机构
[1] Univ Split, Fac Elect & Mech Engn & Naval Architecture, Lab Numer Modeling & Comp Applicat, Rudjera Boskovica 32, Split 21000, Croatia
[2] Univ Split, Fac Elect Engn Mech Engn & Naval Architecture, LTEF Lab Thermodynam & Energy Efficiency, Rudjera Boskovica 32, Split 21000, Croatia
[3] Univ Split, Fac Elect & Mech Engn & Naval Architecture, Dept Elect, Rudjera Boskovica 32, Split 21000, Croatia
关键词
Photovoltaics; Numerical analysis; Passive cooling; Renewable energy; Energy conversion efficiency; FLOW;
D O I
10.1016/j.enconman.2019.112277
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the major issues related to market available silicon based photovoltaic (PV) technologies is the performance drop caused by relatively high PV panel operating temperatures. The proper cooling of PV panels can reduce performance degradation and increase the lifetime of convectional PV panels. This paper investigates architecture modifications to market available silicon PV panels with the introduction of slits on the PV panel surface, which enables the passive cooling of PV panels. Two different arrangements of slits were numerically investigated and followed with the optimization approach. A developed numerical model was derived from the referent numerical model that was experimentally validated. For each considered scenario, a detailed flow and thermal analysis was performed which included optimization regarding minimum average PV cell temperatures. The considered slit types differ with slit orientation, i.e. parallel to PV panel tilt-axis (type-A) and perpendicular to PV panel tilt-axis (type-B). In both cases, a detailed analysis and optimization required similar to 100 CFD simulations to investigate the effects of different slit sizes and all wind directions. Overall, using the considered slit modifications, the average PV cell temperature could be decreased up to 3 degrees C, where effective cooling with the proposed modification is only reasonable for wind speeds up to 5 m/s.
引用
收藏
页数:11
相关论文
共 31 条
  • [1] Abd-Elhady MS, 2018, ENERGY CONVERS MANAG
  • [2] Alami AH, 2014, ENERGY CONVERS MANAG
  • [3] Ana M, 2018, J CLEAN PROD
  • [4] [Anonymous], APPL ENERGY
  • [5] Arabatzis I, 2018, SOL ENERGY
  • [6] Effects of different fin parameters on temperature and efficiency for cooling of photovoltaic panels under natural convection
    Bayrak, Fatih
    Oztop, Hakan F.
    Selimefendigil, Fatih
    [J]. SOLAR ENERGY, 2019, 188 : 484 - 494
  • [7] Chandrasekar M, 2013, ENERGY CONVERS MANAG
  • [8] Cuce E, 2011, INT J LOW CARBON TEC
  • [9] Fayaz H, 2019, SOL ENERGY
  • [10] Experimental investigation of the passive cooled free-standing photovoltaic panel with fixed aluminum fins on the backside surface
    Grubisic-Cabo, Filip
    Nizetic, Sandro
    Coko, Duje
    Kragic, Ivo Marinic
    Papadopoulos, Agis
    [J]. JOURNAL OF CLEANER PRODUCTION, 2018, 176 : 119 - 129