On-line preconcentration system for lanthanum determination in urine using FI-ICP-AES

被引:22
|
作者
Vicente, O [1 ]
Masi, A [1 ]
Martinez, L [1 ]
Olsina, R [1 ]
Marchevsky, E [1 ]
机构
[1] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 San Luis, Argentina
关键词
flow injection; ICP-AES; preconcentration and determination; lanthanum in urine samples;
D O I
10.1016/S0003-2670(98)00105-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line lanthanum preconcentration and determination system implemented with inductively coupled plasma-atomic emission spectrometry (ICP-AES) associated to flow injection (FI) method was studied. For the retention of lanthanum, quinolin-8-ol and Amberlite XAD-7 were used at pH 9.5. The lanthanum complex was removed from the micro-column with nitric acid. The value of detection limit for the preconcentration of 100 mi of aqueous solution was 0.09 ng ml(-1) with a relative standard deviation (RSD) of 1.5%, calculated with the peak heights obtained. The calibration graph using the preconcentration system for lanthanum was linear with a correlation coefficient of 0.9993 at levels near the detection limits up to at least 100 ng ml(-1). The method was successfully applied to the determination of lanthanum in urine samples. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 50 条
  • [31] Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system
    Asadoulahi, Taherah
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (07) : 1353 - 1359
  • [32] Automated on-line separation-preconcentration system for platinum determination by electrothermal atomic absorption spectrometry
    Ojeda, CB
    Rojas, FS
    Pavón, JMC
    de Torres, AG
    ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) : 97 - 103
  • [33] FI on-line chemiluminescence reaction for determination of MCPA in water samples
    Torres-Cartas, S.
    Gomez-Benito, C.
    Meseguer-Lloret, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) : 1289 - 1296
  • [34] FI on-line chemiluminescence reaction for determination of MCPA in water samples
    S. Torres-Cartas
    C. Gómez-Benito
    S. Meseguer-Lloret
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1289 - 1296
  • [35] Determination of Trace Non Rare Earth Elements in High Purity Rare Earth Oxides by ICP-AES with Microcolumn Preconcentration in a Flow Injection System
    吉红念
    廖振环
    江祖成
    谢金娥
    JOURNALOFRAREEARTHS, 1995, (02) : 119 - 124
  • [36] On-line preconcentration using an amberlite XAD-16 resin and determination of cadmium by flow-injection-inductively coupled plasma atomic emission spectrometry
    Acevedo, HA
    Vazquez, FA
    Wuilloud, RG
    Olsina, RA
    Martinez, LD
    CHEMIA ANALITYCZNA, 2001, 46 (01): : 59 - 67
  • [37] FI-ICP-AES中的标准加入法研究和在混合稀土全分析中的应用附视频
    沈菁
    江祖成
    廖振环
    分析试验室, 1991, (02) : 45 - 47
  • [38] Determination of boron in river-water by ICP-AES coupled with anion-exchange preconcentration
    Yoshikuni, N
    Seki, Y
    Iwatsubo, K
    Oguma, K
    BUNSEKI KAGAKU, 2001, 50 (03) : 203 - 208
  • [39] Dissolution of vanadium pentoxide using microwave digestion system for determination of vanadium by ICP-AES
    Choi, Kwang-Soon
    Park, Yang-Soon
    Kim, Yeon-Hee
    Han, Sun-Ho
    Song, Kyuseok
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (06): : 511 - 517
  • [40] Determination of uranium in natural waters and high-purity aluminum by flow-injection on-line preconcentration and ICP-MS detection
    Seki, T