On-line preconcentration system for lanthanum determination in urine using FI-ICP-AES

被引:22
|
作者
Vicente, O [1 ]
Masi, A [1 ]
Martinez, L [1 ]
Olsina, R [1 ]
Marchevsky, E [1 ]
机构
[1] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 San Luis, Argentina
关键词
flow injection; ICP-AES; preconcentration and determination; lanthanum in urine samples;
D O I
10.1016/S0003-2670(98)00105-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line lanthanum preconcentration and determination system implemented with inductively coupled plasma-atomic emission spectrometry (ICP-AES) associated to flow injection (FI) method was studied. For the retention of lanthanum, quinolin-8-ol and Amberlite XAD-7 were used at pH 9.5. The lanthanum complex was removed from the micro-column with nitric acid. The value of detection limit for the preconcentration of 100 mi of aqueous solution was 0.09 ng ml(-1) with a relative standard deviation (RSD) of 1.5%, calculated with the peak heights obtained. The calibration graph using the preconcentration system for lanthanum was linear with a correlation coefficient of 0.9993 at levels near the detection limits up to at least 100 ng ml(-1). The method was successfully applied to the determination of lanthanum in urine samples. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 50 条
  • [1] On-line preconcentration of rare earth element by FIA-ICP-AES
    Lee, GH
    Park, SA
    Song, K
    Cha, HK
    Lee, J
    Lee, SC
    ANALYTICAL SCIENCES, 1997, 13 : 27 - 30
  • [2] Determination of lead in drinking water by ICP-AES with ultrasonic nebulization and flow-injection on-line preconcentration using an amberlite XAD-16 resin
    Wuilloud, RG
    Acevedo, HA
    Vazquez, FA
    Martinez, LD
    ANALYTICAL LETTERS, 2002, 35 (10) : 1649 - 1665
  • [3] FI-ICP-AES标准加入法的研究及其应用
    廖振环
    李凤
    陈世忠
    秦永超
    帅琴
    江祖成
    武汉大学学报(自然科学版), 1999, (06) : 825 - 828
  • [4] Determination of cadmium in water by ICP-AES with on-line adsorption preconcentration using DPTH-gel and TS-gel microcolumns
    Zougagh, M
    de Torres, AG
    Pavón, JMC
    TALANTA, 2002, 56 (04) : 753 - 761
  • [5] Automatic on line preconcentration and determination of lead in water by ICP-AES using a TS-microcolumn
    Zougagh, A
    de Torres, AG
    Alonso, EV
    Pavón, JMC
    TALANTA, 2004, 62 (03) : 503 - 510
  • [6] The efficiency of a microcolumn of rice bran for on-line trace enrichment in FI-AAS, a highly selective system for on-line preconcentration and determination of copper
    Dadfarnia, S.
    Shabani, A. M. Haji
    Gohari, M.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 453 - 458
  • [7] On-line preconcentration system with faas detection for determination of cadmium
    Pyrzynska, K
    Szelag, H
    ANALYTICAL LETTERS, 2001, 34 (12) : 2153 - 2158
  • [8] FI-ICP-AES法检测纺织品中痕量Cr6+
    鲁丹
    鲍晓霞
    阮毅
    赵珊红
    刘雅萍
    印染, 2007, (21) : 41 - 43
  • [9] Metal analysis in pulps by ICP-AES:: Practical aspects of on-line determination
    Sillanpää, M
    Rämö, J
    Piepponen, S
    Rahikkala, A
    PAPERI JA PUU-PAPER AND TIMBER, 2002, 84 (02): : 116 - 118
  • [10] On-line preconcentration system for bismuth determination in urine by flow injection hydride generation inductively coupled plasma atomic emission spectrometry
    Moyano, S
    Wuilloud, RG
    Olsina, RA
    Gásquez, JA
    Martinez, LD
    TALANTA, 2001, 54 (02) : 211 - 219