Scanner for Integrated X-Ray Breast Tomosynthesis and Molecular Breast Imaging Tomosynthesis
被引:0
作者:
Williams, Mark B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USAUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Williams, Mark B.
[1
]
Judy, Patricia G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USAUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Judy, Patricia G.
[1
]
Gong, Zongyi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USAUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Gong, Zongyi
[1
]
Graham, Audrey E.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USAUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Graham, Audrey E.
[1
]
Majewski, Stan
论文数: 0引用数: 0
h-index: 0
机构:
West Virginia Univ, Dept Radiol, Morgantown, WV USAUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Majewski, Stan
[2
]
Gunn, Spencer
论文数: 0引用数: 0
h-index: 0
机构:
Dexela Ltd, London, EnglandUniv Virginia, Dept Radiol, Charlottesville, VA 22903 USA
Gunn, Spencer
[3
]
机构:
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USA
[2] West Virginia Univ, Dept Radiol, Morgantown, WV USA
[3] Dexela Ltd, London, England
来源:
DIGITAL MAMMOGRAPHY
|
2010年
/
6136卷
关键词:
breast tomosynthesis;
molecular breast imaging;
limited angle SPECT;
multimodality imaging;
hybrid scanners;
DIGITAL TOMOSYNTHESIS;
NEOADJUVANT CHEMOTHERAPY;
F-18-FDG PET/CT;
GAMMA-CAMERA;
CANCER;
MAMMOGRAPHY;
SCINTIMAMMOGRAPHY;
OPTIMIZATION;
PERFORMANCE;
RESOLUTION;
D O I:
暂无
中图分类号:
TP301 [理论、方法];
学科分类号:
081202 ;
摘要:
A dual modality tomosynthesis (DMT) breast scanner has been developed that combines x-ray breast tomosynthesis (XBT) and molecular breast imaging tomosynthesis (MBIT) on a common upright gantry to obtain co-registered structural and functional tomosynthesis images. This paper describes the scanner's design and operation, and summarizes the results of a pilot clinical evaluation using the tracer Tc-99m-sestamibi. The pilot study results suggest that DMT breast scanning is feasible and provides improved specificity and positive predictive value compared to XBT alone. Potential clinical roles for DMT scanning include problem solving for equivocal mammographic/ultrasound studies; as an aid in biopsy target selection following a positive mammogram with multiple suspicious areas; cancer surveillance in patients with a personal history of breast cancer; pre-surgical planning for determination of disease extent; as an alternative for women for whom MRI is impossible; and for monitoring response to neoadjuvant therapy.
机构:
Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USADuke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA
Chen, Ying
Lo, Joseph Y.
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA
Lo, Joseph Y.
Dobbins, James T., III
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA
机构:
Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USADuke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA
Chen, Ying
Lo, Joseph Y.
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA
Lo, Joseph Y.
Dobbins, James T., III
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Med Phys Grad Program, Durham, NC 27710 USA