Performance analysis of integrated earth-air-tunnel-evaporative cooling system in hot and dry climate

被引:70
作者
Bansal, Vikas [1 ]
Mishra, Rohit [1 ]
Das Agarwal, Ghanshyam [1 ]
Mathur, Jyotirmay [1 ]
机构
[1] Malaviya Natl Inst Technol, Dept Mech Engn, Jaipur 302017, Rajasthan, India
关键词
Earth-air-tunnel heat exchanger; Evaporative cooling; Passive cooling; Computational fluid dynamics; HEAT-EXCHANGER;
D O I
10.1016/j.enbuild.2011.12.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Performance of simple earth-air-tunnel heat exchanger (EATHE) is enhanced by integrating an evaporative cooler at the outlet. Year round hourly analysis of the integrated system has been carried out for predominantly hot and dry climatic conditions using multiphase computational fluid dynamics (CFD) modeling with FLUENT software (version 6.3). The analysis has been carried out individually for all 8760 h of the year for the city of Ajmer (India), considering the temperature and humidity of ambient air as condition of inlet air. Results show that a simple EATHE system provides 4500 MJ of cooling effect during summer months, whereas 3109 MJ of additional cooling effect can be achieved by integrating evaporative cooler with the EATHE. Although the winter season in most of the cities in hot and dry climatic zones is very short, analysis of the 8760 h show that the EATHE system is capable of providing 4856 MJ equivalent of heating effect at such locations. For every hour, the condition of the outlet air has also been matched with the thermal comfort zone specified ay ASHRAE-55. Results show significant improvement in usefulness of the EATHE system when integrated with evaporative cooler in hot and dry climatic conditions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 14 条
[1]  
Ahmed A., 2015, IBPSA 2009 INT BUILD, V2009, P2228
[2]   The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate [J].
Al-Ajmi, F ;
Loveday, DL ;
Hanby, VI .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :235-244
[3]  
[Anonymous], 552004 ANSIASHRAE
[4]   Performance analysis of earth-pipe-air heat exchanger for summer cooling [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2010, 42 (05) :645-648
[5]   Performance analysis of earth-pipe-air heat exchanger for winter heating [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2009, 41 (11) :1151-1154
[6]   Thermal modeling of a greenhouse with an integrated earth to air heat exchanger: an experimental validation [J].
Ghosal, MK ;
Tiwari, GN ;
Srivastava, NSL .
ENERGY AND BUILDINGS, 2004, 36 (03) :219-227
[7]   Cooled soil as a cooling source for buildings [J].
Givoni, Baruch .
SOLAR ENERGY, 2007, 81 (03) :316-328
[8]   MODELING THE EARTH TEMPERATURE USING MULTIYEAR MEASUREMENTS [J].
MIHALAKAKOU, G ;
SANTAMOURIS, M ;
ASIMAKOPOULOS, D .
ENERGY AND BUILDINGS, 1992, 19 (01) :1-9
[9]   On the heating potential of a single buried pipe using deterministic and intelligent techniques [J].
Mihalakakou, G .
RENEWABLE ENERGY, 2003, 28 (06) :917-927
[10]   On the application of the energy balance equation to predict ground temperature profiles [J].
Mihalakakou, G ;
Santamouris, M ;
Lewis, JO ;
Asimakopoulos, DN .
SOLAR ENERGY, 1997, 60 (3-4) :181-190