Characterization of titanium nitride-hydroxyapatite on PEEK for dental implants by co-axis target magnetron sputtering

被引:14
作者
Boonyawan, Dheerawan [1 ]
Waruriya, Panadda [1 ]
Suttiat, Kullapop [2 ]
机构
[1] Chiang Mai Univ, Dept Phys & Mat Sci, Plasma & Beam Phys Res Facil, Fac Sci, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Dept Prosthodont, Fac Dent, Chiang Mai 50200, Thailand
关键词
Reactive pulse DC magnetron sputtering; Titanium nitride -hydroxyapatite thin film; Polyetheretherketone (PEEK); IN-VITRO; BIOMATERIALS; COATINGS; FILMS; XPS;
D O I
10.1016/j.surfcoat.2016.05.063
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, the bioactive TiN-HA layer has been prepared by reactive DC magnetron sputtering system with co-axis target configuration on the polyetheretherketone (PEEK) bio-inert material. The proper plasma conditions used to deposit TiN-HA film on PEEK were carried out by the optical emission spectroscopy (OES). The relationship between the chemical composition of plasma to sputtering pressure, discharge voltage, duty cycle and the content of nitrogen gas were considered. The plasma emission intensity raised to the maximum level when the N-2 content was 0.6 sccm. The voltage was ranged about 500-700 V for the sputtering pressure at 3-7 mTorr and reduced to below 500 V when the pressure increased to more than 7 mTorr. The clear as-deposited films with high refractive index were observed and found to reduce surface contact angle as much lower as 10 degrees. X-ray photoelectron spectroscopy (XPS) result revealed TiOH was also formed in the deposited film besides TiO2. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 30 条
[21]  
Song T.H.C.M.A., 2011, PHYS PLASMAS, V18
[22]   PROPERTIES OF A TITANIUM NITRIDE COATING FOR DENTAL INSTRUMENTS [J].
STEELE, JG ;
MCCABE, JF ;
BARNES, IE .
JOURNAL OF DENTISTRY, 1991, 19 (04) :226-229
[23]   Processing and properties of hydroxyapatite-based biomaterials for use as hard tissue replacement implants [J].
Suchanek, W ;
Yoshimura, M .
JOURNAL OF MATERIALS RESEARCH, 1998, 13 (01) :94-117
[24]  
SUMNER DR, 1992, CLIN ORTHOP RELAT R, P202
[25]   Influence of bias voltage on the tribological properties of titanium nitride films fabricated by dynamic plasma ion implantation/deposition [J].
Tian, XB ;
Zhang, T ;
Fu, RKY ;
Chu, PK .
SURFACE & COATINGS TECHNOLOGY, 2002, 161 (2-3) :232-236
[26]   Polyetheretherketone as a biomaterial for spinal applications [J].
Toth, JM ;
Wang, M ;
Estes, BT ;
Scifert, JL ;
Seim, HB ;
Turner, AS .
BIOMATERIALS, 2006, 27 (03) :324-334
[27]   Effect of stem stiffness and bone stiffness on bone remodeling in cemented total hip replacement [J].
Wan, ZN ;
Dorr, LD ;
Woodstone, T ;
Ranawat, A ;
Song, M .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :149-158
[28]   E-Glass Fiber Reinforced Composites in Dental Applications [J].
Zhang, Meng ;
Matinlinna, Jukka Pekka .
SILICON, 2012, 4 (01) :73-78
[29]   Improved in vitro and in vivo biocompatibility of dual plasma modified titanium alloy [J].
Zhao, Ying ;
Wong, Sze Man ;
Wong, Hoi Man ;
Pan, Haobo ;
Yeung, Kelvin W. K. ;
Chu, Paul K. .
SURFACE & COATINGS TECHNOLOGY, 2013, 229 :130-134
[30]   Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings [J].
Zheng, XB ;
Huang, MH ;
Ding, CX .
BIOMATERIALS, 2000, 21 (08) :841-849