Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review

被引:111
作者
Sun, Zhonghua [1 ]
Lin, ChengHsun [2 ]
Davidson, Robert [3 ]
Dong, Chiauhuei [2 ]
Liao, Yunchan [2 ]
机构
[1] Curtin Univ Technol, Discipline Med Imaging, Dept Imaging & Appl Phys, Perth, WA 6845, Australia
[2] Cent Taiwan Univ Sci & Technol, Dept Radiol Technol, Taichung, Taiwan
[3] RMIT Univ, Discipline Med Radiat, Bundoora, Vic 3083, Australia
关键词
multislice CT; coronary artery disease; diagnostic value; systematic review;
D O I
10.1016/j.ejrad.2007.07.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To per-form a systematic review of the diagnostic value of 64-multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PUBMED and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing 64-slice MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analysed at segment-, vessel- and patient-based assessment. Results: Fifteen studies met selection criteria and were included for analysis. Pooled sensitivity, specificity, positive predictive value and negative predictive value as well as 95% confidence interval (CI) were 97% (94 and 99%), 88% (79 and 97%), 94% (91 and 97%), and 95% (90 and 99%) for patient-based assessment; 92% (85 and 99%), 92% (85 and 99%), 78% (66 and 91%) and 98% (96 and 99%) for vessel-based assessment; 90% (85 and 94%), 96% (95 and 97%),75%(68 and 82%) and 98% (98 and 99%) for segment-based assessment, respectively. No significant difference was found in the diagnostic accuracy of 64-slice CT in the detection of CAD when comparison was performed either among four main coronary arteries, or between proximal and middle or distal segments (P > 0.05). Conclusion: Our results showed that 64-slice CT angiography has a high-diagnostic value in the detection of CAD. Severe coronary artery calcification seems to be the major factor affecting the visualisation and assessment. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 33 条
[11]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[12]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[13]   Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology - Initial clinical results [J].
Kuettner, A ;
Trabold, T ;
Schroeder, S ;
Feyer, A ;
Beck, T ;
Brueckner, A ;
Heuschmid, M ;
Burgstahler, C ;
Kopp, AF ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1230-1237
[14]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[15]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487
[16]  
MEIJBOOM WB, 2007, HEART IN PRESS
[17]   Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris [J].
Mollet, NR ;
Cademartiri, F ;
Nieman, K ;
Saia, F ;
Lemos, PA ;
McFadden, EP ;
Pattynama, PMT ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) :2265-2270
[18]   High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
van Mieghem, CAG ;
Runza, G ;
McFadden, EP ;
Baks, T ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2005, 112 (15) :2318-2323
[19]   Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients [J].
Muehlenbruch, Georg ;
Seyfarth, Tobias ;
Soo, Chee Siong ;
Pregalathan, Namasivayam ;
Horst Mahnken, Andreas .
EUROPEAN RADIOLOGY, 2007, 17 (03) :603-609
[20]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054