A Hysteresis Current Controller for Single-Phase Three-Level Voltage Source Inverters

被引:81
作者
Mao, Huifeng [1 ,2 ]
Yang, Xu [1 ]
Chen, Zenglu [2 ]
Wang, Zhaoan [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Elect Engn, Power Elect & Renewable Energy Ctr, Xian 710049, Peoples R China
[2] Xian Polytech Univ, Elect & Informat Coll, Xian 710048, Peoples R China
关键词
Dead-time; dead-time effects; field-programmable gate array (FPGA); hysteresis control; three-level inverters; VSI; MODULATION;
D O I
10.1109/TPEL.2011.2181419
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional hysteresis current controllers have the disadvantage of a variable switching frequency. This paper presents a novel hysteresis current control method which uses the adjacent current error zero-crossing time to calculate the upper/lower hysteresis bandwidth after the measured half current error period. This strategy makes the algorithm independent of load parameters and thus it can achieve a stable switching frequency. An improved switching scheme has been successfully applied to a single-phase three-level H-bridge voltage source inverter driving a vibration test bench based on the novel hysteresis current. It can select appropriate switching states to overcome dead-time effects without dead-time compensation according to the relation of the current switching state, the current error, and the upper/lower hysteresis bandwidth. Field-programmable gate array has enough computational power to allow multiple sampling within a current error period and logic control power to implement state machine transitions. The simulation and experimental results are given to demonstrate the validity and features of the novel hysteresis current controller with the improved switching scheme.
引用
收藏
页码:3330 / 3339
页数:10
相关论文
共 22 条
[1]  
Bode GH, 2001, IEEE POWER ELECTRON, P14, DOI 10.1109/PESC.2001.953988
[2]  
Bode GH, 2000, IEEE POWER ELECTRON, P33, DOI 10.1109/PESC.2000.878796
[3]   ZERO AVERAGE CURRENT ERROR CONTROLLED POWER-FLOW FOR AC-DC POWER CONVERTERS [J].
BORLE, LJ ;
NAYAR, CV .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1995, 10 (06) :725-732
[4]   Dead-time elimination for voltage source inverters [J].
Chen, Lihua ;
Peng, Fang Zheng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (02) :574-580
[5]   The Variable-Bandwidth Hysteresis-Modulation Sliding-Mode Control for the PWM-PFM Converters [J].
Chen, Yu ;
Kang, Yong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (10) :2727-2734
[6]   Constant-Frequency Hysteresis Current Control of Grid-Connected VSI Without Bandwidth Control [J].
Ho, Carl Ngai-Man ;
Cheung, Victor S. P. ;
Chung, Henry Shu-Hung .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (11) :2484-2495
[7]   Current control techniques for three-phase voltage-source PWM converters: A survey [J].
Kazmierkowski, MP ;
Malesani, L .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) :691-703
[8]   A Hysteretic Control Method for Multiphase Voltage Regulator [J].
Lee, Kisun ;
Lee, Fred C. ;
Xu, Ming .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (12) :2726-2734
[9]   A time-based double-band hysteresis current regulation strategy for single-phase multilevel inverters [J].
Loh, PC ;
Bode, GH ;
Holmes, DG ;
Lipo, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (03) :883-892
[10]   Improved constant-frequency hysteresis current control of VSI inverters with simple feedforward bandwidth prediction [J].
Malesani, L ;
Mattavelli, P ;
Tomasin, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1194-1202