Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis

被引:18
作者
Godley, Keith Craig [1 ]
Syer, Tom Joseph [2 ]
Toms, Andoni Paul [1 ]
Smith, Toby Oliver [2 ]
Johnson, Glyn [2 ]
Cameron, Donnie [2 ]
Malcolm, Paul Napier [1 ]
机构
[1] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Colney Lane, Norwich NR4 7UY, Norfolk, England
[2] Univ East Anglia, Norwich, Norfolk, England
关键词
Prostate cancer; magnetic resonance imaging; MRI; diffusion-weighted imaging; DWI; high-b-value; meta-analysis; MATHEMATICAL-MODELS; COEFFICIENT VALUES; GLEASON SCORE; 3; T; BIOPSY; DIFFERENTIATION; SPECIMENS; IMAGES; TISSUE; NOISE;
D O I
10.1177/0284185117702181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The diagnostic accuracy of diffusion-weighted imaging (DWI) to detect prostate cancer is well-established. DWI provides visual as well as quantitative means of detecting tumor, the apparent diffusion coefficient (ADC). Recently higher b-values have been used to improve DWI's diagnostic performance. Purpose: To determine the diagnostic performance of high b-value DWI at detecting prostate cancer and whether quantifying ADC improves accuracy. Material and Methods: A comprehensive literature search of published and unpublished databases was performed. Eligible studies had histopathologically proven prostate cancer, DWI sequences using b-values >= 1000s/mm(2), less than ten patients, and data for creating a 2x2 table. Study quality was assessed with QUADAS-2 (Quality Assessment of diagnostic Accuracy Studies). Sensitivity and specificity were calculated and tests for statistical heterogeneity and threshold effect performed. Results were plotted on a summary receiver operating characteristic curve (sROC) and the area under the curve (AUC) determined the diagnostic performance of high b-value DWI. Results: Ten studies met eligibility criteria with 13 subsets of data available for analysis, including 522 patients. Pooled sensitivity and specificity were 0.59 (95% confidence interval [CI], 0.57-0.61) and 0.92 (95% CI, 0.91-0.92), respectively, and the sROC AUC was 0.92. Subgroup analysis showed a statistically significant (P=0.03) improvement in accuracy when using tumor visual assessment rather than ADC. Conclusion: High b-value DWI gives good diagnostic performance for prostate cancer detection and visual assessment of tumor diffusion is significantly more accurate than ROI measurements of ADC.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 46 条
[1]   Is it time to consider a role for MRI before prostate biopsy? [J].
Ahmed, Hashim U. ;
Kirkham, Alex ;
Arya, Manit ;
Illing, Rowland ;
Freeman, Alex ;
Allen, Clare ;
Emberton, Mark .
NATURE REVIEWS CLINICAL ONCOLOGY, 2009, 6 (04) :197-206
[2]  
American Cancer Society, 2012, Cancer Facts Figures 2012
[3]   ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[4]   Use of the percentage of free prostate-specific antigen to enhance differentiation of prostate cancer from benign prostatic disease - A prospective multicenter clinical trial [J].
Catalona, WJ ;
Partin, AW ;
Slawin, KM ;
Brawer, MK ;
Flanigan, RC ;
Patel, A ;
Richie, JP ;
deKernion, JB ;
Walsh, PC ;
Scardino, PT ;
Lange, PH ;
Subong, ENP ;
Parson, RE ;
Gasior, GH ;
Loveland, KG ;
Southwick, PC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 279 (19) :1542-1547
[5]   The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis [J].
Chen Jie ;
Liu Rongbo ;
Tan Ping .
EUROPEAN RADIOLOGY, 2014, 24 (08) :1929-1941
[6]   Prostate cancer detection: Comparison of T2-weighted imaging, diffusion-weighted imaging, proton magnetic resonance spectroscopic imaging, and the three techniques combined [J].
Chen, M. ;
Dang, H. -D. ;
Wang, J. -Y. ;
Zhou, C. ;
Li, S. -Y. ;
Wang, W. -C. ;
Zhao, W. -F. ;
Yang, Z. -H. ;
Zhong, C. -Y. ;
Li, G. -Z. .
ACTA RADIOLOGICA, 2008, 49 (05) :602-610
[7]   Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations [J].
Damon, Bruce M. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) :934-944
[8]  
Dietrich O, 2001, MAGNET RESON MED, V45, P448, DOI 10.1002/1522-2594(200103)45:3<448::AID-MRM1059>3.0.CO
[9]  
2-W
[10]   Negative predictive value for cancer in patients with "Gray-Zone" PSA level and prior negative biopsy: Preliminary results with multiparametric 3.0 tesla MR [J].
Girometti, Rossano ;
Bazzocchi, Massimo ;
Como, Giuseppe ;
Brondani, Giovanni ;
Del Pin, Matteo ;
Frea, Bruno ;
Martinez, Guillermo ;
Zuiani, Chiara .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (04) :943-950