An integrated enzyme-linked immunosorbent assay system with an organic light-emitting diode and a charge-coupled device for fluorescence detection

被引:16
作者
Nakajima, Hizuru [1 ]
Okuma, Yukiko [2 ]
Morioka, Kazuhiro [1 ]
Miyake, Mayo [2 ]
Hemmi, Akihide [2 ,3 ]
Tobita, Tatsuya [2 ,4 ]
Yahiro, Masayuki [5 ]
Yokoyama, Daisuke [5 ]
Adachi, Chihaya [5 ]
Soh, Nobuaki [2 ]
Nakano, Koji [2 ]
Xue, Shuhua [1 ]
Zeng, Hulie [1 ]
Uchiyama, Katsumi [1 ]
Imato, Toshihiko [2 ]
机构
[1] Tokyo Metropolitan Univ, Dept Appl Chem, Grad Sch Urban Environm Sci, Tokyo 1920397, Japan
[2] Kyushu Univ, Dept Appl Chem, Grad Sch Engn, Nishi Ku, Fukuoka 812, Japan
[3] Mebius Adv Technol Ltd, Suginami Ku, Tokyo, Japan
[4] NTT Adv Technol Corp, Kanagawa, Japan
[5] Kyushu Univ, Ctr Future Chem, Nishi Ku, Fukuoka 812, Japan
关键词
CCD; Fluorescence detection; Immunoassay; Microfluidics; Organic light-emitting diode; THERMAL LENS MICROSCOPE; MICROCHIP ELECTROPHORESIS; NONFLUORESCENT MOLECULES; MICROFLUIDIC DEVICE; RAPID-DETERMINATION; IMMUNOGLOBULIN-A; AMINO-ACIDS; CHIP; PLATFORM; FLOW;
D O I
10.1002/jssc.201100429
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 mu W (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N = 3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.
引用
收藏
页码:2906 / 2912
页数:7
相关论文
共 45 条
  • [1] High-efficiency organic electrophosphorescent devices with tris(2-phenylpyridine)iridium doped into electron-transporting materials
    Adachi, C
    Baldo, MA
    Forrest, SR
    Thompson, ME
    [J]. APPLIED PHYSICS LETTERS, 2000, 77 (06) : 904 - 906
  • [2] DNA-encoded antibody libraries: A unified platform for multiplexed cell sorting and detection of genes and proteins
    Bailey, Ryan C.
    Kwong, Gabriel A.
    Radu, Caius G.
    Witte, Owen N.
    Heath, James R.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (07) : 1959 - 1967
  • [3] Concentration dependence of fluorescence signal in a microfluidic fluorescence detector
    Banerjee, Ansuman
    Shuai, Yun
    Dixit, Rahul
    Papautsky, Ian
    Klotzkin, David
    [J]. JOURNAL OF LUMINESCENCE, 2010, 130 (06) : 1095 - 1100
  • [4] An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications
    Chabinyc, ML
    Chiu, DT
    McDonald, JC
    Stroock, AD
    Christian, JF
    Karger, AM
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (18) : 4491 - 4498
  • [5] Electroosmosis- and pressure-driven chromatography in chips using continuous beds
    Ericson, C
    Holm, J
    Ericson, T
    Hjertén, S
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 81 - 87
  • [6] Development and characterization of an ELISA assay in PDMS microfluidic channels
    Eteshola, E
    Leckband, D
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) : 129 - 133
  • [7] An integrated microfluidic device in polyester for electrophoretic analysis of amino acids
    Guo, YL
    Uchiyama, K
    Nakagama, T
    Shimosaka, T
    Hobo, T
    [J]. ELECTROPHORESIS, 2005, 26 (09) : 1843 - 1848
  • [8] On-chip integration of sequential ion-sensing system based on intermittent reagent pumping and formation of two-layer flow
    Hisamoto, H
    Horiuchi, T
    Uchiyama, K
    Tokeshi, M
    Hibara, A
    Kitamori, T
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5551 - 5556
  • [9] Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
    Hofmann, O
    Wang, XH
    deMello, JC
    Bradley, DDC
    deMello, AJ
    [J]. LAB ON A CHIP, 2005, 5 (08) : 863 - 868
  • [10] JACOBSON SC, 1994, ANAL CHEM, V66, P18