Sensitivity of surface plasmon resonance sensors based on metallic columnar thin films in the spectral and angular interrogations

被引:39
作者
Shalabney, Atef [1 ,2 ]
Khare, C. [3 ]
Rauschenbach, B. [3 ,4 ]
Abdulhalim, I. [1 ,2 ]
机构
[1] Ben Gurion Univ Negev, Dept Electro Opt Engn, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Ilse Katz Inst Nanoscale Sci & Technol, IL-84105 Beer Sheva, Israel
[3] Leibniz Inst Surface Modificat, D-04318 Leipzig, Germany
[4] Univ Leipzig, Inst Expt Phys 2, D-04307 Leipzig, Germany
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 159卷 / 01期
关键词
Surface plasmon resonance; Sculptured thin films; Sensitivity enhancement; Optical biosensors; OPTICAL-PROPERTIES; ENHANCEMENT; BIOSENSOR; PHASE; BIO;
D O I
10.1016/j.snb.2011.06.072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surface Plasmon Resonance (SPR) from metallic Columnar Thin Films (CTFs) of porosity as high as 0.5 was experimentally and theoretically investigated. The CTF layers were prepared by the Glancing Angle Deposition (GLAD) method. The SPR features were investigated in both the angular and the spectral modes. In the angular interrogation, increasing the porosity causes broadening to the dip width, shift to larger resonance angles, and increase of the sensitivity to analyte refractive index (RI) changes by about threefold compared with closed metal films. In the spectral interrogation, on the other hand, the resonance wavelengths are red-shifted for porous films; hence their spectral sensitivities are higher than those of closed films under the same experimental conditions. Nevertheless, the sensitivity behavior versus the resonance wavelength is similar to that of SPR sensors based on dense film layers. The shapes of the nanostructures constituting the CH are described as ellipsoidal inclusions in which the effective permittivity dyadic of the composite material is calculated using the Bruggeman formalism with exact depolarization dyadics. The correlation between the sensitivity enhancement and the electromagnetic field intensity at the interface between the metallic film and the analyte was examined. Electromagnetic fields analyses were performed using the general 4 x 4 propagation matrices of general homogenous biaxial layers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:201 / 212
页数:12
相关论文
共 50 条
[21]   Investigation of the structure of iron oxide nanoparticle assemblies in order to optimize the sensitivity of surface plasmon resonance-based sensors [J].
Dolci, Mathias ;
Bryche, Jean-Francois ;
Moreau, Julien ;
Leuvrey, Cedric ;
Begin-Colin, Sylvie ;
Barbillon, Gregory ;
Pichon, Benoit P. .
APPLIED SURFACE SCIENCE, 2020, 527
[22]   A prism-based polymeric surface plasmon resonance biochip for angular and spectral modes [J].
Oliveira, L. C. ;
Moreira, C. S. ;
Lima, A. M. N. ;
Neff, H. .
PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 :1350-1353
[23]   Performance optimization of bi-metallic surface plasmon resonance based sensors with silicon layer using poynting vector analysis [J].
Kushwah, Himanshu ;
Anand, Jagneet Kaur .
OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (10)
[24]   Optical Magnetism in Surface Plasmon Resonance-Based Sensors for Enhanced Performance [J].
Hossain, Md. Mahbub ;
Talukder, Muhammad Anisuzzaman .
PLASMONICS, 2021, 16 (02) :581-588
[25]   Study on the Despeckle Methods in Angular Surface Plasmon Resonance Imaging Sensors [J].
Le Liu ;
Jun Guo ;
Yonghong He ;
Pengfei Zhang ;
Yilong Zhang ;
Jihua Guo .
Plasmonics, 2015, 10 :729-737
[26]   Study on the Despeckle Methods in Angular Surface Plasmon Resonance Imaging Sensors [J].
Liu, Le ;
Guo, Jun ;
He, Yonghong ;
Zhang, Pengfei ;
Zhang, Yilong ;
Guo, Jihua .
PLASMONICS, 2015, 10 (03) :729-737
[27]   Comparative study between polarimetric and intensity-based surface plasmon resonance sensors in the spectral mode [J].
Watad, Ibrahim ;
Abdulhalim, Ibrahim .
APPLIED OPTICS, 2017, 56 (27) :7549-7558
[28]   Interferometric sensors based on surface plasmon resonance [J].
Wu, CM ;
Joe, SF ;
Chang, LB .
OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS II, 2002, 4616 :64-72
[29]   Influence of temperature effects on sensitivity of surface plasmon resonance sensors [J].
Moreira, C. S. ;
Lima, A. M. N. ;
Neff, H. .
2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, :170-+
[30]   Sensitivity of tapered optical fiber surface plasmon resonance sensors [J].
Kumar, Sushil ;
Sharma, Gaurav ;
Singh, Vivek .
OPTICAL FIBER TECHNOLOGY, 2014, 20 (04) :333-335