Multicenter trial for the set-up of a MRI quality assurance programme

被引:16
作者
Colombo, P [1 ]
Baldassarri, A
Del Corona, M
Mascaro, L
Strocchi, S
机构
[1] Osped Niguarda Ca Granda, Dept Hlth Phys, Milan, Italy
[2] Spedali Civil Brescia, Dept Hlth Phys, I-25125 Brescia, Italy
[3] Osped Circolo Varese, Dept Hlth Phys, Varese, Italy
[4] Fdn Macchi, Varese, Italy
关键词
quality assurance; uniformity; signal-to-noise ratio;
D O I
10.1016/j.mri.2003.04.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Many international protocols related to RMI-QC program are focused on acquisition methods and analysis of several image quality parameters but rarely normality ranges or measurement frequencies are presented. To address this problem we investigated the variability of many magnetic resonance imaging (MRI) systems with the set-up of multicenter trial. The trial was set up to investigate short-and mid-term variability of two fundamental nongeometric image quality parameters: signal-to-noise (SNR) and integral percent uniformity (U%). Ten centers (12 devices) participated to data collection consisting of a three-step-protocol. First, 10 consecutive images of a phantom were collected with a spin echo sequence. As second step the series collection was repeated 24 h later. Finally a single image acquisition was performed twice a week for 5 weeks. The analysis of results allowed us to define a "physiological" variability of +/-3% of the reference level for both parameters and to conclude that a weekly measurement is adequate to detect relevant variations of device performance. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 13 条
[1]  
[Anonymous], 1988, MAGN RESON IMAGING, V6, P195
[2]  
Berardi P, 1995, Radiol Med, V89, P310
[3]   A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185
[6]   MULTI-CENTER TRIAL WITH PROTOCOLS AND PROTOTYPE TEST OBJECTS FOR THE ASSESSMENT OF MRI EQUIPMENT [J].
LERSKI, RA ;
MCROBBIE, DW ;
STRAUGHAN, K ;
WALKER, PM ;
DECERTAINES, JD ;
BERNARD, AM .
MAGNETIC RESONANCE IMAGING, 1988, 6 (02) :201-214
[7]   Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom [J].
Magnusson, P ;
Olsson, LE .
MEDICAL PHYSICS, 2000, 27 (08) :1980-1994
[8]  
Mascaro L, 1999, Radiol Med, V97, P389
[9]  
*NEMA, 1988, NEMA STAND PUBL
[10]   ACCEPTANCE TESTING OF MAGNETIC-RESONANCE-IMAGING SYSTEMS - REPORT OF AAPM NUCLEAR-MAGNETIC-RESONANCE TASK GROUP NO-6 [J].
OCH, JG ;
CLARKE, GD ;
SOBOL, WT ;
ROSEN, CW ;
MUN, SK .
MEDICAL PHYSICS, 1992, 19 (01) :217-229