Radiation Doses in Patients Undergoing Computed Tomographic Coronary Artery Calcium Evaluation With a 64-Slice Scanner Versus a 256-Slice Scanner

被引:2
|
作者
Madaj, Paul [1 ]
Li, Dong [1 ]
Nakanishi, Rine [1 ,2 ]
Andreini, Daniele [3 ]
Pontone, Gianluca [3 ]
Conte, Edoardo [3 ]
O'Rourke, Rachael [4 ,5 ]
Hamilton-Craig, Christian [4 ]
Nimmagadda, Manojna [1 ]
Kim, Nicholas [1 ]
Fatima, Badiha [1 ]
Dailing, Christopher [1 ]
Shaikh, Kashif [1 ]
Shekar, Chandana [1 ]
Lee, Ju Hwan [1 ]
Budoff, Matthew J. [1 ]
机构
[1] Harbor UCLA Med Ctr, Dept Med, Lundquist Inst, 1124 W Carson St, Torrance, CA 90502 USA
[2] Toho Univ, Dept Cardiovasc Med, Dept Internal Med, Fac Med, Tokyo, Japan
[3] Ist Ricovero & Cura Carattere Sci, Dept Cardiol, Ctr Cardiol Monzino, Milan, Italy
[4] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[5] Univ Queensland, Dept Cardiol, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
Coronary angiography/methods; coronaryartery disease/diagnostic imaging; multi-detector computed tomography/instrumentation; predictive value of tests; prospective studies; radiation dosage; radiation exposure/prevention & control; risk factors; vascular calcification/diagnostic imaging; ASSOCIATION TASK-FORCE; ITERATIVE RECONSTRUCTION; CARDIOVASCULAR RISK; AMERICAN-COLLEGE; STRATIFICATION; PROGRESSION; CARDIOLOGY; REDUCTION; GUIDELINE; DISEASE;
D O I
10.14503/THIJ-18-6793
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Computed tomographic coronary artery calcium scanning enables cardiovascular risk stratification; however, exposing patients to high radiation levels is an ongoing concern. New-generation computed tomographic systems use lower radiation doses than older systems do. To quantify comparative doses of radiation exposure, we prospectively acquired images from 220 patients with use of a 64-slice GE LightSpeed VCT scanner (control group, n=110) and a 256-slice GE Revolution scanner (study group, n=110). The groups were matched for age, sex, and body mass index; statistical analysis included t tests and linear regression. The mean dose-length product was 21% lower in the study group than in the control group (60.2 +/- 27 vs 75.9 +/- 22.6 mGy.cm; P <0.001) and also in each body mass index subgroup. Similarly, the mean effective radiation dose was 21% lower in the study group (0.84 +/- 0.38 vs 1.06 +/- 0.32 mSv) and lower in each weight subgroup. After adjustment for sex, women in the study group had a lower dose-length product (50.4 +/- 23.4 vs 64.7 +/- 27.6 mGy.cm) than men did and received a lower effective dose (0.7 +/- 0.32 vs 0.9 +/- 0.38 mSv) (P=0.009). As body mass index and waist circumference increased, so did doses for both scanners. Our study group was exposed to radiation doses lower than the previously determined standard of 1 mSv, even after adjustment for body mass index and waist circumference. In 256-slice scanning for coronary artery calcium, radiation doses are now similar to those in lung cancer screening and mammography.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Individualized Assessment of Radiation Dose in Patients Undergoing Coronary Computed Tomographic Angiography With 256-Slice Scanning
    Perisinakis, Kostas
    Seimenis, Ioannis
    Tzedakis, Antonis
    Papadakis, Antonios E.
    Damilakis, John
    CIRCULATION, 2010, 122 (23) : 2394 - 2402
  • [2] Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner
    Benz, Dominik C.
    Grani, Christoph
    Moch, Beatrice Hirt
    Mikulicic, Fran
    Vontobel, Jan
    Fuchs, Tobias A.
    Stehli, Julia
    Clerc, Olivier F.
    Possner, Mathias
    Pazhenkottil, Aju P.
    Gaemperli, Oliver
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    ACADEMIC RADIOLOGY, 2016, 23 (08) : 1008 - 1014
  • [3] Improved image quality at 256-slice coronary CT angiography in patients with a high heart rate and coronary artery disease: comparison with 64-slice CT imaging
    Oda, Seitaro
    Katahira, Kazuhiro
    Utsunomiya, Daisuke
    Takaoka, Hiroko
    Honda, Keiichi
    Noda, Katsuo
    Oshima, Shuichi
    Yuki, Hideaki
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2015, 56 (11) : 1308 - 1314
  • [4] Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women
    Jug, Borut
    Gupta, Mohit
    Papazian, Jenny
    Li, Dong
    Tsang, Janet
    Bhatia, Harpreet
    Karlsberg, Ronald
    Budoff, Matthew
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (06) : 1154 - 1161
  • [5] Performance of dual source versus 256-slice multi-slice CT in the evaluation of 16 coronary artery stents
    Andre, Florian
    Korosoglou, Grigorios
    Hosch, Waldemar
    Giannitsis, Evangelos
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Steen, Henning
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 601 - 607
  • [6] Evaluation of the anatomical variations of the coronary venous system in patients with coronary artery calcification using 256-slice computed tomography
    Bai, Wei
    Xu, Xiao
    Ji, Haixia
    Liu, Jing
    Ma, Heng
    Xie, Haizhu
    Dong, Jianjun
    Sun, Chunjuan
    Shi, Yinghong
    Che, Kaili
    Liu, Meijie
    Guo, Yingkun
    PLOS ONE, 2020, 15 (11):
  • [7] Assessment of the coronary venous system with prospective electrocardiography (ECG)-Triggered coronary computed tomography angiography (CCTA) using a 256-Slice Scanner
    Sun, Chunjuan
    Xing, Dong
    Xie, Haizhu
    Li, Jian
    Zhang, Zhongsheng
    Shi, Yinghong
    Geng, Junzu
    Huo, Futao
    Ma, Heng
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 212 : 387 - 389
  • [8] Low-dose CT coronary angiography using iterative reconstruction with a 256-slice CT scanner
    Carrascosa, Patricia
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    WORLD JOURNAL OF CARDIOLOGY, 2013, 5 (10): : 382 - 386
  • [9] 64-Slice Multidetector Computed Tomographic Evaluation of Arterial Conduit Patency after Off-Pump Coronary Artery Bypass Grafting
    Mannacio, Vito A.
    Imbriaco, Massimo
    Iesu, Severino
    Gioardano, Agostino La Marca
    Di Tommaso, Luigi
    Vosa, Carlo
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (05) : 409 - 415
  • [10] Diagnostic Accuracy of Dual-Source 64-Slice Multidetector Computed Tomography in Evaluation of Coronary Artery Bypass Grafts
    Sahiner, Levent
    Canpolat, Ugur
    Yorgun, Hikmet
    Hazirolan, Tuncay
    Karcaaltincaba, Musturay
    Sunman, Hamza
    Kaya, Ergun Baris
    Aytemir, Kudret
    Oto, Ali
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (08) : 1180 - 1185