The Association Between Modiolar Base Anomalies and Intraoperative Cerebrospinal Fluid Leakage in Patients With Incomplete Partition Type-II Anomaly: A Classification System and Presentation of 73 Cases

被引:11
作者
Bajin, Munir Demir [1 ]
Pamuk, Ahmet Erim [2 ]
Pamuk, Gozde [1 ]
Ozgen, Burce [3 ]
Sennaroglu, Levent [1 ]
机构
[1] Hacettepe Univ, Dept Otorhinolaryngol, Fac Med, Ankara, Turkey
[2] Akyurt State Hosp, Dept Otorhinolaryngol, TR-06750 Ankara, Turkey
[3] Hacettepe Univ, Dept Radiol, Fac Med, Ankara, Turkey
关键词
Cerebrospinal fluid leakage; Cochlear implant surgery; Gusher; Incomplete partition; Inner ear malformations; Oozing; COCHLEAR IMPLANTATION; CONGENITAL-MALFORMATIONS; INNER-EAR;
D O I
10.1097/MAO.0000000000001871
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective:Modiolus and modiolar base abnormalities in patients with incomplete partition-II anomaly (IP-II) increase the risk of intraoperative cerebrospinal fluid (CSF) leakage. This study aimed to classify modiolar abnormalities and define objective radiological measures for preoperatively evaluating intraoperative CSF leakage risk.Study Design:Retrospective case series.Setting:Tertiary referral center.Patients:The study included 73 patients with IP-II that underwent cochlear implant surgery between 2002 and 2017.Intervention:Analysis of preoperative temporal bone computed tomography (CT) scans and surgical records.Main Outcome Measures:Preoperative CT modiolar anomalies and intraoperative CSF leakage status.Results:Among the 73 patients (41 men and 32 women), mean age at cochlear implant surgery was 11.4 (range, 0-42) years. Preoperative CT-based modiolar base anomaly classification was as follows: grade 1 (complete modiolus, n=1), grade 2 (thin plate of bone in the modiolar base+partial modiolus, n=14); grade 3 (thin plate of bone in the modiolar base, n=53); grade 4 (total modiolar base defect, n=5). The gusher rate was 8%. All patients with grade 4 anomaly had an intraoperative gusher. Patients with grade 3 anomaly accounted for 86% of oozing cases. Oozing, pulsation, and no CSF leakage rates were similar in those with grade 2 anomaly.Conclusions:The modiolus and modiolar base must be carefully evaluated in patients with IP-II. Gushers primarily occur in IP-II patients with grade 4 anomaly. A thin plate of bone in the modiolar base most commonly prevents gushers.
引用
收藏
页码:e538 / e542
页数:5
相关论文
共 20 条
[1]  
Cabbarzade Cavid, 2015, Cochlear Implants Int, V16, P233, DOI 10.1179/1754762813Y.0000000048
[2]  
Cassano P, 2003, Acta Otorhinolaryngol Ital, V23, P116
[3]  
Free RH, 2013, OTOL NEUROTOL, V34, P1033, DOI 10.1097/MAO.0b013e318289841b
[4]  
Graham JM, 2000, J LARYNGOL OTOL, V114, P1
[5]  
JACKLER RK, 1987, LARYNGOSCOPE, V97, P2
[6]  
Jensen S., 1969, ACTA RADIOL, V286, P1
[7]  
Kempf HG, 1999, LARYNGO RHINO OTOL, V78, P529
[8]   The prediction of CSF gusher in cochlear implants with inner ear abnormality [J].
Liu Hongjian ;
Wang Guangke ;
Ma Song ;
Ding Xiaoli ;
Zhang Daoxing .
ACTA OTO-LARYNGOLOGICA, 2012, 132 (12) :1271-1274
[9]   THE MONDINI DYSPLASIA - FROM EARLY DIAGNOSIS TO COCHLEAR IMPLANT [J].
MANGABEIRAALBERNAZ, PL .
ACTA OTO-LARYNGOLOGICA, 1983, 95 (5-6) :627-631
[10]   Endoscopically guided placement of prefabricated cochlear implant electrodes in a common cavity malformation [J].
Manolidis, S ;
Tonini, R ;
Spitzer, J .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2006, 70 (04) :591-596