Outgassing measurement of an LHC collimator and estimation for the NEG performances

被引:5
作者
Kamiya, Junichiro [1 ,2 ]
Baglin, Vincent [2 ]
Bregliozzi, Giuseppe [2 ]
Jimenez, Jose Miguel [2 ]
机构
[1] J PARC Japan Atom Energy Agcy, Tokai, Ibaraki 3191195, Japan
[2] CERN, CH-1211 Geneva 23, Switzerland
关键词
Outgassing rate; NEG coatings; Particle accelerators; Collimators; LHC; NONEVAPORABLE GETTER FILMS;
D O I
10.1016/j.vacuum.2011.03.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The outgassing rate of the collimators in the Large Hadron Collider (LHC) at CERN has an important role for the life-time of the Non-Evaporable Getter (NEC), and an accurate analysis allows the definition of future activities, like NEC vacuum activation. For these reasons, both, total outgassing rate and gas composition of a secondary collimator have been measured in the laboratory. The outgassing rate decreases by about two orders of magnitude by after bake-out and moreover, repeated bake-out further reduced the outgassing rate. The gas transmission through the NEC coated beam pipes and the resulting pressure distributions near the collimator were also measured in a dedicated setup. It is found that the main gas component after just 2 m of NEC coated beam pipe is CH(4) due to the extreme pumping speed of NEC for the other gases. Large amount of outgassing for H(2) and carbon related molecules are released when moving the collimator jaws. It is found that the NEC is very effective even in such case with large gas load. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1178 / 1181
页数:4
相关论文
共 35 条
  • [1] Measurement of Outgassing Rates of Steels
    Park, Chongdo
    Kim, Se-Hyun
    Ki, Sanghoon
    Ha, Taekyun
    Cho, Boklae
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (118):
  • [2] Estimation of mechanical vibrations of the LHC Fast Magnetic Measurement system
    Brooks, Nathan R.
    Bottura, Luca
    Perez, Juan G.
    Dunkel, Olaf
    Walckiers, Louis
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 1617 - 1620
  • [3] On Precision Measurement of the LHC Absolute Luminosity
    Krasny, M. W.
    Chwastowski, J.
    Cyz, A.
    Slowikowski, K.
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2014, 2014, 9290
  • [4] Automatic Threshold Selection for BLM Signals during LHC Collimator Beam-Based Alignment
    Valentino, Gianluca
    Assmann, Ralph W.
    Bruce, Roderik
    Redaelli, Stefano
    Sammut, Nicholas
    2012 SIXTH UKSIM/AMSS EUROPEAN SYMPOSIUM ON COMPUTER MODELLING AND SIMULATION (EMS), 2012, : 210 - 213
  • [5] A Machine Learning Approach for the Tune Estimation in the LHC
    Grech, Leander
    Valentino, Gianluca
    Alves, Diogo
    INFORMATION, 2021, 12 (05)
  • [6] Towards precise top mass measurement at LHC
    Kawabata, Sayaka
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 270 : 196 - 200
  • [7] Luminosity measurement method for the LHC: The detector requirement studies
    Krasny, M. W.
    Chwastowski, J.
    Cyz, A.
    Slowikowski, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 949 - 961
  • [8] Measurement of the Hadronic Resonance Production with ALICE at the CERN LHC
    Vasileiou, Maria
    UNIVERSE, 2019, 5 (01):
  • [9] Luminosity measurement method for LHC: The theoretical precision and the experimental challenges
    Krasny, M. W.
    Chwastowski, J.
    Slowikowski, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (01) : 42 - 52
  • [10] Measurement of outgassing characteristics from a vacuum chamber fabricated for pressure calibration in UHV/XHV region
    Ichimura, S
    Kokubun, K
    Hirata, M
    Tsukahara, S
    Saito, K
    Ikeda, Y
    VACUUM, 1999, 53 (1-2) : 291 - 294