Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis

被引:41
作者
Heywang-Koebrunner, Sylvia H. [1 ,2 ]
Jaensch, Alexander [1 ,2 ]
Hacker, Astrid [1 ,2 ]
Weinand, Sina [3 ]
Vogelmann, Tobias [3 ]
机构
[1] Natl Reference Ctr Mammog Munich, Sonnenstr 29, D-80331 Munich, Germany
[2] FFB gGmbH, Munich, Germany
[3] LinkCare GmbH, Stuttgart, Germany
关键词
Systematic review; Meta-analysis; Mammography; Breast neoplasms; Early detection of cancer; SYNTHETIC 2D MAMMOGRAPHY; RECONSTRUCTED PROJECTION IMAGES; DIAGNOSTIC-TEST ACCURACY; 3D MAMMOGRAPHY; INTERVAL; PERFORMANCE; RATES;
D O I
10.1007/s00330-021-08308-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Digital breast tomosynthesis (DBT) plus digital mammography (DM) in screening is problematic due to increased radiation by the double exposure. Synthesised two-dimensional mammography (s2D) calculated from DBT datasets at no additional dose appears a sensible alternative compared to adding DM. This systematic review and meta-analysis focuses on screening performance outcomes in women screened with DBT plus s2D compared to DM alone. Methods PubMed was searched from January 1, 2010, to September 2, 2020. Studies comparing DBT plus s2D to DM alone in breast cancer screening were included. Pooled risk ratios (RR) were estimated for cancer detection rates (CDR), recall rates, interval cancer rates (ICR), biopsy rates, and positive predictive values for recalls (PPV-1), for biopsies recommended (PPV-2), and for biopsies performed (PPV-3). Sensitivity analyses were performed using the leave-one-out approach. Risk of bias (RoB) was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Results Twelve papers covering 414,281 women were included from 766 records identified. CDR is increased ([RR, 95% CI] 1.35, 1.20-1.52), recall rates are decreased (0.79, 0.64-0.98), and PPV-1 is increased (1.69, 1.45-1.96) when using DBT plus s2D compared to DM alone. ICR and biopsy rates did not differ, but PPV-2 respectively PPV-3 increased with DBT plus s2D (1.57, 1.08-2.28 respectively 1.36, 1.17-1.58). Overall RoB of studies was assessed to be low. Conclusion Results show improved diagnostic outcomes with DBT plus s2D compared to DM alone and underline the value of DBT in combination with s2D in breast cancer screening.
引用
收藏
页码:2301 / 2312
页数:12
相关论文
共 41 条
[1]   Synthetic 2D Mammography Versus Standard 2D Digital Mammography: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis [J].
Abdullah, Peri ;
Alabousi, Mostafa ;
Ramadan, Sherif ;
Zawawi, Ismaiel ;
Zawawi, Mayar ;
Bhogadi, Yasovineeth ;
Freitas, Vivianne ;
Patlas, Michael N. ;
Alabousi, Abdullah .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (02) :314-324
[2]   Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis [J].
Alabousi, Mostafa ;
Wadera, Akshay ;
Al-Ghita, Mohammed Kashif ;
Al-Ghetaa, Rayeh Kashef ;
Salameh, Jean-Paul ;
Pozdnyakov, Alex ;
Zha, Nanxi ;
Samoilov, Lucy ;
Sharifabadi, Anahita Dehmoobad ;
Sadeghirad, Behnam ;
Freitas, Vivianne ;
McInnes, Matthew D. F. ;
Alabousi, Abdullah .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06) :680-690
[3]   Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis [J].
Alabousi, Mostafa ;
Zha, Nanxi ;
Salameh, Jean-Paul ;
Samoilov, Lucy ;
Sharifabadi, Anahita Dehmoobad ;
Pozdnyakov, Alex ;
Sadeghirad, Behnam ;
Freitas, Vivianne ;
McInnes, Matthew D. F. ;
Alabousi, Abdullah .
EUROPEAN RADIOLOGY, 2020, 30 (04) :2058-2071
[4]   Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population [J].
Aujero, Mireille P. ;
Gavenonis, Sara C. ;
Benjamin, Ron ;
Zhang, Zugui ;
Holt, Jacqueline S. .
RADIOLOGY, 2017, 283 (01) :70-76
[5]   Breast Cancer Characteristics Associated with 2D Digital Mammography versus Digital Breast Tomosynthesis for Screening-detected and Interval Cancers [J].
Bahl, Manisha ;
Gaffney, Shannon ;
McCarthy, Anne Marie ;
Lowry, Kathryn P. ;
Dang, Pragya A. ;
Lehman, Constance D. .
RADIOLOGY, 2018, 287 (01) :49-57
[6]   Effect of implementing digital breast tomosynthesis (DBT) instead of mammography on population screening outcomes including interval cancer rates: Results of the Trento DBT pilot evaluation [J].
Bernardi, Daniela ;
Gentilini, Maria A. ;
De Nisi, Martina ;
Pellegrini, Marco ;
Fanto, Carmine ;
Valentini, Marvi ;
Sabatino, Vincenzo ;
Luparia, Andrea ;
Houssami, Nehmat .
BREAST, 2020, 50 :135-140
[7]   Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study [J].
Bernardi, Daniela ;
Macaskill, Petra ;
Pellegrini, Marco ;
Valentini, Marvi ;
Fanto, Carmine ;
Ostillio, Livio ;
Tuttobene, Paolina ;
Luparia, Andrea ;
Houssami, Nehmat .
LANCET ONCOLOGY, 2016, 17 (08) :1105-1113
[8]   Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program [J].
Caumo, Francesca ;
Zorzi, Manuel ;
Brunelli, Silvia ;
Romanucci, Giovanna ;
Rella, Rossella ;
Cugola, Loredana ;
Bricolo, Paola ;
Fedato, Chiara ;
Montemezzi, Stefania ;
Houssami, Nehmat .
RADIOLOGY, 2018, 287 (01) :37-46
[9]   Comparison of breast cancers detected in the Verona screening program following transition to digital breast tomosynthesis screening with cancers detected at digital mammography screening [J].
Caumo, Francesca ;
Romanucci, Giovanna ;
Hunter, Kylie ;
Zorzi, Manuel ;
Brunelli, Silvia ;
Macaskill, Petra ;
Houssami, Nehmat .
BREAST CANCER RESEARCH AND TREATMENT, 2018, 170 (02) :391-397
[10]  
Commission (EU), 2019, EUROPEAN GREEN DEAL, DOI [10.2833/9937, DOI 10.2833/9937]